Manual abstract: user guide NAPCO FIREWOLFBROCHURE
Detailed instructions for use are in the User's Guide.
[. . . ] Powerful battery capacity up to 32Ah total. Features remote smoke obscuration reporting
NAC Extender provides nearly 7A and 4 onboard NACs with up to 2A ea; up to 16Ah total battery capacity. [. . . ] · Medium Enclosure supports 16 AH at 24V. Dimensions: 16"x 14. 25" x 5. 2" (H x W x D) without cover. (*Note: Only 1 SLC is accomodated. ) 16Ah battery backup capacity. Zones can come from any of the following initiating devices: · Addressable SLC Loop supports up to (2) 126 point loops · Commercial RF Receiver · Supports Commercial Wireless Fire devices · Wireless Smoke Detector · Wireless Heat Detector · Conventional 1- to 4-zone EZM Expansion modules on the 4-wire fire bus or SLC loops · Conventional 2-wire or 4-wire smoke detector input module · SLC Fire Devices Supported: · Analog Smoke Detector · Analog Heat Detector · Duct Detector · Pull Station · Conventional Zone Module · Short Circuit Isolator OUTPUTS Up to 96 outputs · Four on board Class B or 2 Class A NAC circuits, 2 amps each, total 6. 5 amps at 24V · Built in Wheelock and System Sensor NAC sync/strobe/horn protocol allows initial silence of audible appliances while maintaining visual notification, without the use of additional modules. · Addressable SLC Fire Devices: Supervised relay, unsupervised relay · Fire 4-wire bus devices: 8 zone form C relay (GEMC-RM3008), 8 open collector output (GEMC-OUT8) Advantages · Easy Wire Compatibility - Addressable SLC controller supports shielded, unshielded, twisted and untwisted wire - ideal for retrofits · Longer SLC loop lengths, support more device loads each, too (see below for distance at maximum device load in alarm/ standby each): · 10, 000 ft. #18AWG · Support for Legacy and Existing Notification Appliances -One NAC output configurable for 12V for compatibility for easy retrofit compatibility · UL Regulated NAC outputs · Automatic drift compensation for smoke detectors · Keypads mount anywhere on the bus and have flash-able firmware for updates via Quickloader command (# GEMC-FK1, shown above) · Programmable obscuration level by smoke detector device · Smoke Obscuration Report genererated remotely or locally or in any of 3 ways - Quickloader device sensitivity report allows the printout of a report for the AHJ listing the current status of all smoke detectors in the system including the programmed obscuration level and the actual sensitivity reading for each device. This report can be generated remotely (uploaded) or locally through notebook PC or use optional onsite printer. · Full line of UL Commercial Devices for more flexibility & labor-savings Example, Use Gemini Commercial Wireless 2-input module (GEMCWL-WD2) to convert any UL listed fire device into a UL wireless device, ideal for sprinkler supervisories or for use with pull stations (mounts on top of wall/conduit or in deep sngle-gang box (plastic). · Separate 7Amp 4-NAC Extender (GEM-NAC7) 4 onboard NACs with up to 2A ea. , expandable for up to 24 per system. Monitors AC, battery trouble, tamper and ground fault on Napco bus - Also Provides Universal FACP support for easy standardization in upgrades
(Shown above) 32-Point GEM-C FirewolfTM 24V Commercial Fire System Agencies
NFPA 72, UL Commercial Fire, UL864 9th Ed. , UL985. (CSFM, FM, MEA listings pending. )
FIREWOLF SYSTEM COMPONENTS
FIREWOLF-SERIES LARGE ENCLOSURE (SHOWN)
(TELCO 1 REMOTE DOWNLOAD / REPORTING)
(TELCO 2 SECOND REPORTING LINE)
4 OR 7 AMP MAIN POWER SUPPLY (GEMC-PS24V7A-R or GEMC-PS24V4A-R)
FIRE BUS DEVICES
GEMC-F8ZCPIM 8 Fire Zone Expander
GEMC-EZM8
8 ZONE CONVENTIONAL ZONE EXPANSION MODULE
MOTHERBOARD
GEMC-RECV
WIRELESS RECEIVER
(4, MAX. )
2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE
GEMC-OUT8
+ + +
SMOKE 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE 2-WIRE SMOKE SMOKE SMOKE SMOKE SMOKE
S
+ + + +
SMOKE 2-WIRE
+ +
S
+
+
S S
+
SMOKE SMOKE SMOKE SMOKE SMOKE
+
S S
+ + +
+
S S S
+ + EOLR 2. 2K EOLR 2. 2K +
+ +
S S
+
+
S S
GEMC-FW-SLC
SMOKE 2-WIRE
GEMC-FW-SLC
FIRE SLC MODULE
+ +
SMOKE SMOKE SMOKE
MUST BE ALL WHEELOCK OR ALL SYSTEM SENSOR
MUST BE ALL WHEELOCK OR ALL SYSTEM SENSOR
8 ZONE OUTPUT REMOTE RELAY MODULE
FIRE SLC MODULE
(MAXIMUM 2) HORN
EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K
(MAXIMUM 2) HORN STROBE STROBE HORN HORN HORN HORN STROBE HORN STROBE
2-WIRE FIRE SLC ADDRESSABLE LOOP
S
+
+
S
+
+
+
S
+
GEMC-WL-SMK
GEMC-24VR
STROBE
}
8 ZONES OF CONVENTIONAL 2-WIRE SMOKES PULL STATIONS AND/OR HEAT DETECTORS
24 VOLT BOOSTER MODULE
FWC-FSLC-SMK
HORN HORN HORN STROBE STROBE HORN HORN STROBE
GEMC-RM3008
OUTPUT MODULE
SMOKE DETECTOR
GEMC-WL-HEAT
GEMC-NL-MOD
INTERNET REPORTING ADDRESSABLE SMOKE DETECTOR STROBE STROBE HORN HORN
BATTERIES
BATTERIES
HEAT DETECTOR
FWC-FSLC-HEAT
GEMC-WL-WD2 GEMC-12V2APS-CF
12V AUX POWER SUPPLY Single Fire initiating N/O device
· 4 ON-BOARD NAC CIRCUITS (CLASS B) (SHOWN) -- or -· 2 ON-BOARD NAC CIRCUITS (CLASS A)
STROBE STROBE STROBE EOLR 2. 2K EOLR 2. 2K
}
EOLR 2. 2K EOLR 2. 2K HORN HORN HORN HORN HORN STROBE HORN HORN HORN STROBE STROBE HORN HORN STROBE HORN STROBE STROBE STROBE STROBE HORN HORN STROBE HORN STROBE STROBE STROBE
ADDRESSABLE HEAT DETECTOR EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K EOLR 2. 2K
STROBE
SINGLE ZONE TRANSMITTER WITH TAMPER
FWC-FSLC-PULL
}
· 4 ON-BOARD NAC CIRCUITS (CLASS B) -- or -· 2 ON-BOARD NAC CIRCUITS (CLASS A) (NOT SHOWN)
FWC-FSLC-EZM1
FAST RESPONSE MONITOR MODULE
GEMC-FPRINT
PRINTER MODULE
PULL
ADDRESSABLE PULL STATION
FWC-FSLC-DUCT
GEMC-NAC7
MUST BE ALL WHEELOCK OR ALL SYSTEM SENSOR
OF F IREW L
NAC EXTENDER
(5, MAX. )
DUCT DETECTOR
FWC-FSLC-EZM2
4 OR 7 AMP MAIN POWER SUPPLY
F EWF L IR O
BATTERIES
FWC-FSLC-SOM1 FWC-FSLC-RM2
BATTERIES
DUAL INPUT MONITOR MODULE
FEWF IR O L
F EWF L IR O
SUPERVISED OUTPUT MODULE
DUAL RELAY MODULE
FWC-FSLC-ISO
FWC-FSLC-CZM
FWC-FSLC-SMK6B
GEMC-FK1
UP TO 126 DEVICES
F EWF L IR O
F EWF RL IO
2 SLC MODULES, max.
SHORT CIRCUIT ISOLATOR CONVENTIONAL ZONE MODULE (6" BASE ONLY)
Note: The four GEMC-RECV max. is reduced by 1 for each SLC module.
FIRE KEYPAD
NAPCO COMMERCIAL FIREWOLF SERIES SYSTEM ORDERING INFO.
Napco Commercial Fire Kits
GEMC-FW-255KT 255 Point GEM-C FirewolfTM 24V Commercial Fire System Kit · 24V Panel, 255 Points via commercial addressable, wireless or conventional fire devices, 4 on board NACs providing up to 6. 5A notification power · 7 Amp, 24V Power Supply · Built in horn/strobe synch. [. . . ] Addressable SLC 1-input conventional module, similar to usage above. Addressable SLC single module, for montoring of dry contacts, ie. , pull stations and conv. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO FIREWOLF
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.