User manual NAPCO MAGNUM ALERT RP1010 KEYPAD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO MAGNUM ALERT RP1010 KEYPAD. We hope that this NAPCO MAGNUM ALERT RP1010 KEYPAD user guide will be useful to you.

Lastmanuals help download the user guide NAPCO MAGNUM ALERT RP1010 KEYPAD.


Mode d'emploi NAPCO MAGNUM ALERT RP1010 KEYPAD
Download
Manual abstract: user guide NAPCO MAGNUM ALERT RP1010 KEYPAD

Detailed instructions for use are in the User's Guide.

[. . . ] Gemini-C Burglary & Firewolf Menu-Driven Custom Alpha Keypads Familiar Napco ez-programming. Compliances - NFPA 72, UL Commercial Fire, UL864 9th Ed. , SIA CP01, UL985. UL household & commercial burg. : UL1610, UL609, UL365, UL1023 (CSFM, FM, MEA listings pending. ) NAC Extender provides nearly 7A and 4 onboard NACs with up to 2A ea; up to 16Ah total battery capacity. Easily distributes synched bell and strobe outputs with built in module. [. . . ] Easily distributes synched bell and strobe outputs with built in module. Monitors AC, battery trouble, tamper and ground fault on Napco bus or provides universal FACP support. Napco CommercialTM Platform MAGNUM ALERT RP1010 KEYPAD System Components: 24V Fire, Burglary or Combination Burg. /Fire Systems SYSTEM · Main Control board supports up to (2) Addressable SLCs (Signaling Line Circuit controllers). · Fire Addressable SLC Loop Controller · Burg Addressable SLC Loop Controller · Fire 4-wire bus for keypads and conventional devices · Burglary Control Module · Provides Isolated Burg 4-wire bus for keypads and conventional devices · Provides independent Burg battery connection and charger · Provides 12V power · Independent Burg Bell output · Power Supply includes either 4A or 7A @ 24V · Integrates with NAPCO ACM ­ Access Control Modules · RS-232 Printer Module for optional onsite parallel printer · Supports a maximum of 15 Keypads, mounted anywhere on the bus, fire MAGNUM ALERT RP1010 KEYPAD-FK1 or burg. Or, as few as 1 fire keypad required on fire system or equipment savings. ) · Addressable SLC Loop Isolator (optional use - for some fire applications requiring increased circuit integrity) · Dual Phone Line built in · 2 Onboard Serial Ports - One for internet reporting; One for highspeed local downloading · TCP/IP Internet reporting module · Regulated Auxiliary Power Supplies - Commercial Burglary or fire, 12V regulated 2A or 1. 75A version with plug in transfomer · Choice of two panel enclosures - Between the studs enclosure, recess or surface mount. Larger version, with reversible door, supports up to 32Ah at 24V. Dimensions: 24" x 14. 25" x 5. 2" (H x W x D) without cover. Removable battery shelves, accomodate pairs of 7Ah, 7. 5Ah and 8Ah batts. Smaller Enclosure ­ supports 16Ah at 24V. Dimensions: 16" x 14. 25" x 5. 2" (H x W x D) without cover. Points/Zones can come from any of the following initiating devices (in up to 8 partitionable areas): · Addressable SLC Loop (Burg or Fire) ­ supports up to (2) 126 point loops · Commercial RF Receiver ­ · Supports Commercial Wireless Fire devices · Wireless Smoke Detector · Wireless Heat Detector · Supports Commercial Wireless Burglary devices · Wireless PIR Sensor · Wireless Dual Technology Sensor · Wireless Glass break Sensor · Wireless 2-Point Window/Door Transmitter · Conventional 1- to 4-zone EZM Expansion modules on the 4-wire burg or fire bus or SLC loops · Conventional 2-wire or 4-wire smoke detector input module · Addressable SLC Fire Devices Supported: · Analog Smoke Detector · Heat Detector · Duct Detector · Pull Station · Conventional Zone Module · Short Circuit Isolator · Addressable SLC Burg Devices Supported: · 1 Zone Burg Input Module · 4 Zone Burg Input modules · PIR Motion Sensor · Dual Tech Microwave/PIR Sensor OUTPUTS Up to 96 outputs · Four on board Class B or 2 Class A NAC circuits, 2 amps each, total 6. 5 amps at 24V · Built in Wheelock and System Sensor NAC sync/strobe/horn protocol allows initial silence of audible appliances while maintaining visual notification, without the use of additional modules. Complete separation of fire and burg power, plus indep. battery connection and charger for indep. Burg Module, isolated 4-wire burg bus for burg keypads and devices, plus 12V power output for aux devices. Addressable SLC Fire Module, supports up to 128 addressable SLC fire devices. Addressable SLC Burg Module, supports up to 128 addressable SLC burg devices. Conventional 8-zone 2-wire fire input module. Plugs into GEM-C panel, for conventional 2-wire smokes or any conventional fire detection device. Fire Peripherals LCD Burglary Keypad for Combo. System, with 4-zone EZM built in (Requires MAGNUM ALERT RP1010 KEYPAD-BM or BM/PS Module. ) Addressable SLC 4 point input expansion module Addressable SLC 1 point input expansion module Addressable SLC Commercial Dual Tech Microwave/PIR, 40 x 40' Addressable SLC Commercial PIR, 50 x 50' Addressable SLC Commercial 1 point output module Gemini Commercial Wireless PIR, 50 x 50' Gemini Commercial Wireless Glassbreak, Acoustic 25' Gemini Commercial Wireless Dual Tech Microwave/PIR, 40 x 40' LCD Fire Red Keypad Gemini Commercial Wireless Smoke, Photoelectric Gemini Commercial Wireless Heat, 135º F Gemini Comml Wireless 2-input module converts any UL listed device into a UL wireless device (ex. , pull stations or sprinkler supervisories. ) Gemini Commercial Wireless 255 point RF Receiver (up to 4 per system, max. ) 8-point expansion module Parallel printer module 8 Form C Relay Output Module Internet Reporting Module RS232 Adapter for serial output from MAGNUM ALERT RP1010 KEYPAD Panel PGM Output Module, 8 open collector PGM outputs Merchantile Tamper Kit, for large panel enclosures, supervised. (Not necessary if housing is recess-mounted. ) Addressable Analog SLC Smoke, photoelectric, head** Addressable Analog SLC Heat, 135ºF, head** Addressable SLC Duct smoke detector, photoelectric Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indepent contact monitoring circuits, for pull stations, water flow and other dry contact alarm initiating devices. [. . . ] (Not necessary if housing is recess-mounted. ) Addressable Analog SLC Smoke, photoelectric, head** Addressable Analog SLC Heat, 135ºF, head** Addressable SLC Duct smoke detector, photoelectric Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indepent contact monitoring circuits, for pull stations, water flow and other dry contact alarm initiating devices. Addressable SLC 1-input conventional module, similar to usage above. Addressable SLC single module, for montoring of dry contacts, ie. , pull stations and conv. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO MAGNUM ALERT RP1010 KEYPAD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO MAGNUM ALERT RP1010 KEYPAD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag