User manual NAPCO MAGNUM ALERT RP1016 KEYPAD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO MAGNUM ALERT RP1016 KEYPAD. We hope that this NAPCO MAGNUM ALERT RP1016 KEYPAD user guide will be useful to you.

Lastmanuals help download the user guide NAPCO MAGNUM ALERT RP1016 KEYPAD.


Mode d'emploi NAPCO MAGNUM ALERT RP1016 KEYPAD
Download
Manual abstract: user guide NAPCO MAGNUM ALERT RP1016 KEYPAD

Detailed instructions for use are in the User's Guide.

[. . . ] Monitors AC, battery trouble, tamper and ground fault on Napco bus or provides universal FACP support. Regulated Auxiliary Power Supplies Commercial fire, 12V regulated 2A models; or 1. 75A version with plug-in transformer Firewolf Advanced Analog Addressable Commercial Fire Devices support auto-drift compensation and maintenance alert function Gemini-C New UL Commercial Wireless Line with supervised tamper & automatic, continuously supervised signal strength (requires no manual test activation). Firewolf Menu-Driven Custom Alpha Keypads Same familiar Napco ezprogramming and usage. [. . . ] (CSFM, FM, MEA listings pending. ) Napco CommercialTM Firewolf-Series Components for 32 to 255 Point 24V Commercial Fire Systems: SYSTEM · Main Control board supports up to two (2) Addressable Fire SLCs (addressable Signaling Line Circuit controllers). (Note: Only 1 SLC is accomodated within the Medium panel enclosure. *) · Fire 4-wire bus for keypads and non-SLC (conventional) devices, including 12V devices · Power Supply includes either 4A or 7A @ 24V · RS-232 Printer Module for optional onsite parallel printer · Supports up to 7 fire keypads, GEMC-FK1, mounted anywhere on the bus. (As few as one keypad required on system for equipment savings. ) · Easy-to-use Gemini-style menu-driven operation with backlit custom alphanumeric display and functionality for Reset, Acknowledge, Silence (with disable). · Full Keyswitch Support · Synch module built in on each NAC (System Sensor & Wheelock protocols) · Dual Phone Line built in · 2 On board serial ports - one for internet reporting; one for high-speed local downloading · TCP/IP Internet reporting module · Regulated Auxiliary Power Supplies - Commercial fire, 12V regulated 2A or 1. 75A version with plug in transfomer · Addressable SLC Loop Isolator (optional use - for some fire applications requiring increased circuit integrity, e. g. , meets Class A, Style 7 loop requirements. · Choice of two enclosures - Between the studs enclosures, recess or surface mount ­ · Larger version supports up to 32 AH at 24V. Dimensions: 24" x 14. 25" x 5. 2" (H x W x D) without cover. Removable battery shelves, accommodate pairs of 7Ah, 7. 5Ah and 8Ah batteries, etc. · Medium Enclosure ­ supports 16 AH at 24V. Houses up to 16Ah battery backup. GEMC-FW-128KT GEMC-FW-32KT Conventional Fire System Peripherals GEMC-FK1 GEMC-F8ZCPIM GEMC-EZM8 GEMC-NL-MOD GEMC-WL-SMK GEMC-WL-HEAT GEMC-WL-WD2 GEMC-REVC GEMC-FW-SLC FWC-FSLC-SMK FWC-FSLC-HEAT FWC-FSLC-DUCT FWC-FSLC-EZM2 FWC-FSLC-EZM1 FWC-FSLC-CZM FWC-FSLC-RM2 FWC-FSLC-ISO FWC-FSLC-SOM1 FWC-FSLC-PULL FWC-FSLC-PROG2 FWC-FSLC-SMK6B LCD Fire Red Keypad (Menu-driven operation, functionality for Reset, Acknowledge, Silence (with disable). Conventional 8-zone 2-wire fire input module. Plugs into motherboard, for conventional 2-wire smoke detectors or any conventional fire detection device. 8-point expansion module Internet Reporting Module Gemini Comml Wireless Smoke, Photoelectric Gemini Comml Wireless Heat, 135º F Gemini Comml Wireless 2-input module Gemini Commercial Wireless 255 point RF Receiver (Up to 4 per system, max. ) Addressable SLC Fire Module, supports up to 128 addressable SLC fire devices, below. Addressable Analog SLC Smoke, photoelectric, head** Addressable Analog SLC Heat, 135ºF, head** Addressable SLC Duct smoke detector, photoelectric Addressable SLC 2-zone conventional expansion module. Uses one address on SLC loop, but yields 2 indep. contact monitoring circuits, for pull stations, water flow and other dry contact alarm initiating devices. Addressable SLC 1-input conventional module, similar to usage above. [. . . ] Addressable SLC 1-input conventional module, similar to usage above. Addressable SLC single module, for montoring of dry contacts, ie. , pull stations and conv. smokes Addressable SLC 2-output module (requires 1 SLC address) Addressable SLC Short Circuit Module (Optional: For special applications, meets Class A, Style 7 loop reqts. ) Addressable SLC Fire supervised output module. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO MAGNUM ALERT RP1016 KEYPAD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO MAGNUM ALERT RP1016 KEYPAD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag