User manual NAPCO MAGNUM ALERT RP1016 LCD KEYPAD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO MAGNUM ALERT RP1016 LCD KEYPAD. We hope that this NAPCO MAGNUM ALERT RP1016 LCD KEYPAD user guide will be useful to you.

Lastmanuals help download the user guide NAPCO MAGNUM ALERT RP1016 LCD KEYPAD.


Mode d'emploi NAPCO MAGNUM ALERT RP1016 LCD KEYPAD
Download
Manual abstract: user guide NAPCO MAGNUM ALERT RP1016 LCD KEYPAD

Detailed instructions for use are in the User's Guide.

[. . . ] These detection devices are divided among separate areas known as "zones", set up throughout your premises. Each zone number corresponds to a Zone light on your Keypad's gray display area. When a zone's red light is ON (or lit), it indicates that one or more detection device(s) assigned to that area are active o r open. For example, if Zone 1 is the front door, and it is open, the Zone 1 light will be on. If zone 2 is a motion detector, and the re is movement in that area, Zone light 2 will turn ON. [. . . ] 7 Oi218a page 7 Tuesday, September 16, 1997 08:28 Disarming Your System / Silencing an Alarm Disarming Your System when Returning 1 2 ARMED READY SYSTEM FIRE AC Enter your premises through the Entry/Exit door. The keypad will sound a steady tone to remind you to disarm the system before your Entry Delay time expires. The Red Armed light will go out, indicating that the system has been disarmed. Note: If you make a mistake entering your code, press the Alarm Indication If the Red Armed light is flashing rapidly, an alarm occurred while you were away. For your own protection, leave immediately and call authorities from a neighbor's phone . Silencing an Alarm In the event that the system goes into alarm due to a violated burglary zone, the bell or siren will sound and the keypad sounder will also activate. To silence the system, enter your User code. The zone light of the is pressed to reset the alarm memory. zone which went into alarm will continue to flash until ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 Silencing a Fire Alarm In the event that the Fire alarm activates due to an violated smoke or fire detector, the bell or siren will sound a distinct pulsating tone. The Red FIRE light on the keypad will be flashing, and the keypad sounder will emit a pulsing tone. If a Fire Alarm does occur: 1 2 3 4 If a fire is in progress, evacuate the premises immediately!Call the Fire Department from an outside phone. If there is no evidence of a fire, enter your User Code. Refer to the following table to determine the cause of the trouble. will scroll to the next, and then exit the If there is more than one trouble to be viewed, pressing 'SYSTEM mode if there are no additional troubles to view. ARMED READY SYSTEM FIRE AC , 'SYSTEM Keypad Beeps or Zone light ON Flashes 1 Beep 1 System Trouble Condition AC Power Failure Action This trouble will occur if AC power is not present. Make sure system transformer is plugged into AC receptacle and check circuit breaker, otherwise call installing company for service. If there has been a recent power failure, the battery may be partially depleted and must be recharged by the control panel. If the trouble does not go away in 24 hours, call installing company for service. The system was not able to report to central station. If this is due to a temporary interruption in the telephone service, the trouble can be cleared when the service is restored by pressing Otherwise, call installing company for service. If telephone service has been temporarily interrupted, the trouble will clear it is when restored. Otherwise, call installing company for service. There is a problem with the Bell or Siren. Call installing company for service. ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 1 Beep 2 Low Battery 1 Beep 3 Communication Failure 1 Beep 4 Telephone Line Cut . 2 Beeps 1 Bell/Siren Trouble 12 Oi218a page 12 Tuesday, September 16, 1997 08:28 9System Troubles 'SYSTEM Keypad Beeps or Flashes 2 Beeps 2 Beeps 2 Beeps ARMED READY SYSTEM FIRE AC Zone light System Trouble ON Condition 2 Fire Trouble 3 4 1-6 Action 3 Beeps ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5 ZONE 6 4 Beeps 1-6 5 Beeps 1-4 6 Beeps 1-4 7 Beeps 1-6 A problem has been detected in the Fire Circuit. [. . . ] Any action for breach of warranty, including but not limited to any implied warranty of merchantab ility, must be brought within the six months following the end of the warranty period. IN NO CASE SHALL NAPCO BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE OR FAULT. In case of defect, contact the security professional who installed and maintains your security system. In order to exercise the warranty, the product must be returned by the security professional, shipping costs prepaid and insured to NAPCO. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO MAGNUM ALERT RP1016 LCD KEYPAD

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO MAGNUM ALERT RP1016 LCD KEYPAD will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag