User manual NAPCO MAGNUM FIRE ALERT 6000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAPCO MAGNUM FIRE ALERT 6000. We hope that this NAPCO MAGNUM FIRE ALERT 6000 user guide will be useful to you.

Lastmanuals help download the user guide NAPCO MAGNUM FIRE ALERT 6000.


Mode d'emploi NAPCO MAGNUM FIRE ALERT 6000
Download
Manual abstract: user guide NAPCO MAGNUM FIRE ALERT 6000

Detailed instructions for use are in the User's Guide.

[. . . ] Secure MSDE/MSSQL technology and open database information sharing with CA ExchangeDB Import and Export features. Scalable, flexible architecture of robust enterprise-class software provides an easy to use and easy to install solution for any size facility with unsurpassed down load speeds. Interoperability for all the functions required in today's increasingly stringent security environment in one easy-to-use graphical workstation interface. · · · · More Information Continental Access reserves the right to modify these specifications at any time. Changes and updates to this document will be made available as they are released. [. . . ] The operator shall be able to print a report of this list directly from the Badgeholders IN screen to any printer on the system or it can be generated automatically in response to an event or input. T. The system shall enable the administrator. To determine the time schedules and access groups that will be contained within a particular Access Control Panel. ARCHITECTURAL AND ENGINEERING SPECIFICATION, v 2. 7 27 b. To determine the exact counts of badges, access groups and time schedules that will be contained within a particular Access Control Panel. To determine the presence of any Time Schedules or Access Groups that will no longer be used by the system. The system shall accommodate various badge data formats, simultaneously, by allowing the system operator to enter into the system, the information about the data contained within a particular badge. The system shall support multiple badge formats, simultaneously. The Badge Format function shall support American Banking Association (ABA), FIPS 201-1, PIV II, CHUID TWIC and Wiegand data formats. The system software shall have the capacity to download a minimum of ten (10) user defined badge formats to each panel. These formats will allow for the use of several card technologies, simultaneously. Alternately, the system shall support 100, 000 system facility codes per panel with Facility Code/Badge Concatenation. Photo/Map: If the Photo/Maps option is enabled, the system should automatically display each user's photo and/or map. Each alert record will provide the following information: a. Class, Description, Location, Date, Priority, Operator that acknowledged the alert and the time it was acknowledged either through the ACS software or the ACS stand alone map software directly on the Map. Alarm Description: Each alarm point may be defined with a plain text description of up to 40 characters. Alarm Enabling: Alarm points will be enabled during user-definable time schedules and they can be manually silenced from any workstation. Additional Alarms: The system shall also generate alarms for the following: a. Enclosure tampering Access Control Panel communication loss/restore Alarm tampering (supervised) Alarms shall be capable of utilizing events generated by the ACS software. 11. Alarm supervision: When using supervised alarm points, the system shall monitor for "OPEN", SHORT", and "GROUND FAULT" in addition to NORMAL/ABNORMAL conditions. Alarm points will have the capability to output an ASCII text command for CCTV switched interface. This command/output will be user-definable and transmitted on alarm points going into abnormal state, returning to a normal state, or both, and for specified reader events as well. The system operator will be able to choose to assign a floor plan to each alert/ event. [. . . ] The contractor shall furnish audiovisual equipment and other training materials and supplies as necessary. Where the contractor presents portions of the course by audiovisual material, copies of the audiovisual material shall be delivered to the owner on the same media as that used during the training session. Up to ____ hours of training shall be provided for in the base contract. 3. 3. General: The contractor shall perform pre-delivery testing, site testing, and adjustment of the completed ACS. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAPCO MAGNUM FIRE ALERT 6000

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAPCO MAGNUM FIRE ALERT 6000 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag