User manual NAVMAN DIESEL MULTI FLOW SENSORS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NAVMAN DIESEL MULTI FLOW SENSORS. We hope that this NAVMAN DIESEL MULTI FLOW SENSORS user guide will be useful to you.

Lastmanuals help download the user guide NAVMAN DIESEL MULTI FLOW SENSORS.


Mode d'emploi NAVMAN DIESEL MULTI FLOW SENSORS
Download
Manual abstract: user guide NAVMAN DIESEL MULTI FLOW SENSORS

Detailed instructions for use are in the User's Guide.

[. . . ] DIESEL FUEL FLOW SENSORS Installation and Operation Manual English . . . . . . . . . . . . . . . . . . . . 73 www. navman. com NAVMAN FCC Statement Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a normal installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. [. . . ] 8 Setup the Navman instrument to use the fuel flow sensors and tachometer, as described in the instrument's installation and operation manual. Take the boat on a test run and check that the sensors are performing correctly. 2 3 4 6 7 If you are unsure where a part should be installed, mount and wire the part temporarily, without cutting holes in the boat. After the sea trials have been completed, install and wire the part permanently. 7-1 Twin engine installations If the boat has twin engines then a second diesel flow sensor kit can be fitted and connected to the same Navman instrument. To install the kits, fit a kit to each engine, following the instructions above for each engine and tank. At the display unit, connect the sensor cables from the two kits in parallel (see section 7-7-2). The sensors need to be identified as port and starboard in the display unit. You may find more instructions included in the display head manual. 22 NAVMAN Diesel fuel flow sensor kit Installation and Operation Manual 7-2 Notes on pipes, fittings and installation This section discusses fuel pipes terminology and the fittings and tape used to join the pipes. 7-2-1 Pipe Diesel fuel lines are often solid copper pipe. Copper pipes are rated by their diameter: Usually fuel lines will be called by their outside diameter (OD) - this is also typical of refrigeration pipe fittings. However, domestic copper water pipe is commonly measured by its inside diameter (ID). So ½ inch refrigeration pipe is a different size from ½ inch water pipe - make sure you know what size your boat fuel piping is before you purchase fittings to install the sensors. Push the flare nut along the pipe before flaring the pipe!!Then flare the end of the pipe using the flaring tool. Inspect the inside face of the flared pipe - it must be smooth and scratch-free. If it is not, cut it off and try again. 7-2-3 Flexible Hoses. Flexible hoses can make installation a lot easier, but modern recommendations are that only one short length of flexible hose should be used - on the final link from the pipework fixed to the boat to the engine, to allow for flexing and vibration. In many countries a boat licensed to carry paying passengers has stringent codes of installation practice to comply with - frequently these require fixed, rigid fuel piping until the last section. If your boat has to meet such inspections, then check carefully before attempting to use flexible hoses. At the very least you may have to use metal braided flexible hose to meet fire regulations. There are also recommendations that the fittings on the end of the flexible hose should be professionally hydraulically crimped on. Failing that, there are recommendations on specific forms of field fitted hose fittings. Check the use of flexible hoses against Coast Guard recommendations, ABYC guidelines or with a marine surveyor before deciding to use flexible hose on your boat. 7-2-2 Flare Nuts Flare nuts are often used to connect a sensor to a solid copper fuel line. There are two different systems of flare fittings: 45 degree flare: 45 degree fittings are more common, and are in standard use for refrigeration pipe work. 37½ degree flare: 37½ degree fittings are more common for hydraulic systems. JIC fittings are 37½ degree flare. [. . . ] #604-842, 2F, 1118-15, Janglim1-Dong, Saha-Gu, Busan, Korea. Ph: +82 51 293 8589 Fax: +82 51 265 8984 e-mail: info@kumhomarine. com web: www. kumhomarine. com Maldives Maizan Electronics Pte. Mobile: +960 78 24 44 Ph: +960 32 32 11 Fax: +960 32 57 07 e-mail: ahmed@maizan. com. mv Singapore and Malaysia, Brunei, Indonesia and Phillipines RIQ PTE Ltd. Blk 3007, 81 Ubi Road 1, #02-440, Singapore 408701. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NAVMAN DIESEL MULTI FLOW SENSORS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NAVMAN DIESEL MULTI FLOW SENSORS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag