User manual NEC DSX-40 HARDWARE MANUAL

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NEC DSX-40. We hope that this NEC DSX-40 user guide will be useful to you.

Lastmanuals help download the user guide NEC DSX-40.


Mode d'emploi NEC DSX-40
Download

You may also download the following manuals related to this product:

   NEC DSX-40 QUICK START GUIDE (375 ko)

Manual abstract: user guide NEC DSX-40HARDWARE MANUAL

Detailed instructions for use are in the User's Guide.

[. . . ] Empowered by Innovation Components Installation Optional Equipment Specifications and Parts DSX-40 Hardware Manual P/N 1093097 Rev 1, October 2006 Printed in U. S. A. 01. 01. 09 For additional resources, visit our Technical Support site on the web at http://www. necdsx. com. This manual has been developed by NEC Unified Solutions, Inc. It is intended for the use of its customers and service personnel, and should be read in its entirety before attempting to install or program the system. Any comments or suggestions for improving this manual would be appreciated. Forward your remarks to: NEC Unified Solutions, Inc. [. . . ] For each 66M1-50 block, punch down the Installation Cable in standard color-code order. Lines 1-8 To make your own cables, see Making Your Own Cables (page 33). 25-PAIR CABLE RJ61X BLOCK TERM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50 COLOR CODE WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU BLU-BLK BLK-ORN ORN-BLK BLK-GRN GRN-BLK BLK-BRN BRN-BLK BLK-SLT SLT-BLK YEL-BLU BLU-YEL YEL-ORN ORN-YEL YEL-GRN GRN-YEL YEL-BRN BRN-YEL YEL-SLT SLT-YEL VIO-BLU BLU-VIO VIO-ORN ORN-VIO VIO-GRN GRN-VIO VIO-BRN BRN-VIO VIO-SLT SLT-VIO FUNCTION 1 1 2 2 3 3 4 4 5 5 6 6 7 7 8 8 T R T R T R T R T R T R T R T R RJ61X Installation 1 10 93 09 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 DSX-40 Hardware Manual 7 - 10 2 NC NC 1 2 NC 8 1 RJ61X Plug Figure 10: Punch Down for Lines Installation 31 Connecting Extensions and Lines Securing the Cables Securing the Ground Wires and Station Cables After you have punched down your cables, route them down the side of the cabinet and secure them with the strain relief. Figure 11: Securing the Cables Securing the AC Power Cord Snap in the provided power cord strain relief and install the cord as shown below. Figure 12: Installing the AC Power Cord and Strain Relief 32 Installation 1093097 - 11 10930 97 - 14 DSX-40 Hardware Manual Connecting Extensions and Lines Making Your Own Cables Making Your Own Installation Cables The following products should help if you make your own cables. The connector is generally referred to as a RJ45 connector wired in an RJ61X configuration. Check with your local supplier for other comparable products. Suttle SE-266-8K 8 Position Modular Plug (requires an SE-166 or SE-166-6 modular crimping tool). Hubbell BRFT4P Snap-On 8 Position Modular Plug (does not require a special crimping tool). To 66 Block WHT-BLU (1T) To CPU Mod Jack RJ61X Pin 1 2 3 4 5 6 7 8 80000 - 18C Installation Port Designation 4T 3T 2T 1R 1T 2R 3R 4R BLU-WHT (1R) WHT-ORN (2T) ORN-WHT (2R) WHT-GRN (3T) GRN-WHT (3R) WHT-BRN (4T) Latch faces up Note reversal BRN-WHT (4R) Figure 13: 8-Pin (RJ61X) Jack Pinouts Connecting Extensions A fully expanded DSX-40 can connect up to 26 extensions. The basic Main Equipment Cabinet provides 8 digital station ports and 2 analog station ports built in. The configuration of the remaining 16 station ports depends on the combination of 8-Port Digital Station and 8-Port Analog Station Cards installed. See Installing Expansion Cards (page 25) for more. Using Figure 9: Punch Down for Extensions (page 30) as a guide, plug the installation cable plugs into the appropriate jacks on the Main Equipment Cabinet. Install a modular jack for each extension within 6 feet of the telephone's location. For each extension, run one-pair 24 AWG station cable from the station block to the modular jack. - To make adds, moves, and changes easier, be sure to leave a service loop in your station cable. Terminate the station cable WHT/BLU - BLU/WHT leads to the RED and GRN lugs in the modular jack. Install bridging clips as required. DSX-40 Hardware Manual Installation 33 Connecting Extensions and Lines 1093097 - 12 25-PAIR CABLE RJ61X BLOCK TERM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 COLOR CODE WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU FUNCTION 300 300 301 301 302 302 303 303 304 304 305 305 306 306 307 307 308 308 309 309 310 T R T R T R T R T R T R T R T R T R T R T RJ61X 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 ESIU ESIU YEL YEL BLU-WHT BLK WHT-BLU RED RED GRN GRN BLU-WHT BLK WHT-BLU 1 2 625 Modular Jack 625 Modular Jack 3 Station Block 1 25-PAIR CABLE RJ61X BLOCK TERM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 COLOR CODE WHT-BLU BLU-WHT WHT-ORN ORN-WHT WHT-GRN GRN-WHT WHT-BRN BRN-WHT WHT-SLT SLT-WHT RED-BLU BLU-RED RED-ORN ORN-RED RED-GRN GRN-RED RED-BRN BRN-RED RED-SLT SLT-RED BLK-BLU FUNCTION 324 T 324 R 325 T 325 R NC NC NC NC Door 1T Door 1R Relay 1T Relay 1R Door 2T Door 2R Relay 2T Relay 2R NC NC NC NC 310 T RJ61X 5 4 3 6 2 7 1 8 5 4 3 6 2 7 1 8 5 4 3 6 2 DSS Console 301 SLIU DSX Keyset 300 1 YEL BLU-WHT BLK WHT-BLU RED GRN 2 625 Modular Jack 3 Station Block 2 DTH-1-1 324 Figure 14: Connecting Extensions 34 Installation DSX-40 Hardware Manual Connecting Extensions and Lines Connecting Lines A fully expanded DSX-40 can connect up to 8 analog loop-start lines with built-in Caller ID. The basic Main Equipment Cabinet provides 4 lines. By adding a 4-Port Line Card you can connect the system to 8 lines. See Installing Expansion Cards (page 25) for more. Using Figure 10: Punch Down for Lines (page 31) as a guide, plug the installation cable plugs into the appropriate jacks on the Main Equipment Cabinet. For each line, run one pair cross-connect wire between the line block and the CPE (customer side) of the telco's RJ21X. Install bridging clips as required. Installation One-Pair Cross Connect 1093097 - 13 Line Block Telco RJ21X 25-Pair Cable to Central Office 25-Pair Installation Cable (P/N 808920) Figure 15: Installing Analog Lines DSX-40 Hardware Manual Installation 35 Setting Up the Telephone and DSS Console Setting Up the Telephone and DSS Console Installing the DSX Keyset Handset and Line Cord. When installing the handset, plug the handset cord into the handset jack on the bottom of the telephone. The handset cord routes through the lower channel on the right side of the telephone base. The line cord does not use a channel and drapes down from the telephone line cord jack or connects to the telephone legs. Figure 16: Installing the Handset and Line Cord Installing the DSX Keyset Optional Headset When installing an optional headset, plug the headset cord in the headset jack on the bottom of the telephone. [. . . ] In places where shocks or vibrations are frequent or strong. In places where water or other fluids come in contact with the main equipment. In areas near high-frequency machines or electric welders. Near computers, telexes, microwaves, air conditioners, etc. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NEC DSX-40

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NEC DSX-40 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag