User manual NILES IPOWER AC-6

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NILES IPOWER AC-6. We hope that this NILES IPOWER AC-6 user guide will be useful to you.

Lastmanuals help download the user guide NILES IPOWER AC-6.


Mode d'emploi NILES IPOWER AC-6
Download
Manual abstract: user guide NILES IPOWER AC-6

Detailed instructions for use are in the User's Guide.

[. . . ] I N S TA L L AT I O N & O P E R AT I O N G U I D E TM Intelligent Power Management Systems. AC-6+ 6 OUTLET POWER MANAGEMENT SYSTEM B LENDING H IGH F IDELITY AND A RCHITECTURE ® IMPORTANT SAFETY PRECAUTIONS Your iPOWERTM product represents the latest in power management and protection technology. However, like any electronic device, an inappropriately or improperly installed device may not perform as intended. By following a few common sense precautions, your iPOWERTM product will give you a lifetime of worry-free performance. The following safety precautions apply to all iPOWERTM products. [. . . ] Additionally, the Trigger feature of the AC-6+ will be disabled so that the Triggered outlets cannot be automatically powered on or off, regardless of whether there is 12 volts present at the 12 Volt Trigger Inputs. KEY TECHNOLOGIES UL 1449 Second Edition Listing The UL 1449 Second Edition procedure is considered to be the most rigorous and demanding series of tests for surge protection devices in the world. In order for a surge protection device to obtain this UL certification, it must pass a battery of "torture" tests ensuring that the product will meet a set of established safety and performance standards. Your AC-6+ is UL 1449 Second Edition listed. 6 UNIT DETAILS UNIT DETAILS 7 The AC-6+ features three pairs of premium quality, wall transformer-spaced outlets. One outlet is Always On, one outlet is Switched on by the power button, and two pairs are Triggered on via either of the 12V trigger inputs. Power Button turns on Switched outlets and puts Triggered outlets into standby mode for remote triggering. Switched LED indicates the status of the Switched outlets and that Triggered outlets are in standby mode. Ground OK LED indicates that the wall outlet wiring is properly grounded. Line OK LED indicates that the wall outlet is free of any problems such as a polarity inversion. Dual Zone 12V Input Triggers enable you to turn on your system from either of two components (includes unique 12V DC 200mA wall adapter for triggering a device). Bus Output Trigger enables the 12V inputs to automate turn-on of other iPOWER products or protected equipment whenever the 12V trigger input is used. 6 ft. industrial grade, high-current handling power cord with flat, 360º rotating plug. Patent pending i3TM power protection circuitry ensures protection time after time. If the AC line in your house is properly grounded, the GROUND OK light will illuminate. If the GROUND OK light does not illuminate, stop your installation. Check the AC connection and make sure that the unit is plugged in properly. If the GROUND OK light still fails to illuminate, have the AC outlet in the house checked by an electrician to diagnose the ground problem. 10 Placement PLANNING YOUR SYSTEM 11 It is recommended that the AC-6+ be placed in a location easily reached when manually operating the other controls in the system. There should be a clear line of sight between the operator and the unit to allow easy user feedback of system status. The AC-6+ should be placed on a flat, stable shelf or platform or, if desired, it can be wall mounted. See the following section for directions on wall mounting. IMPORTANT: Be sure to follow the "Safety Precautions" in the front of this manual to ensure proper product performance and safety. Wall Mounting Once you have decided where your AC-6+ should be placed, you may wish to permanently mount it in that location. Mounting screw slots are provided on all AC Series iPOWERTM products for such purposes. On the back of each unit you will find a series of L-shaped slots designed to accommodate mounting screws. The L-shape of the openings allows for both vertical and horizontal positioning of the unit. [. . . ] DO NOT operate your AC-6+ without a proper ground. The LINE OK indicator on the front panel of the AC-6+ does not light up. · This indicates that the wall outlet has a line problem such as polarity inversion. This is common, especially in older homes. DO NOT operate the AC-6+ with a line problem. Call your electrician to have the line repaired. TROUBLESHOOTING (continued) SYMPTOM Both the LINE OK indicator and the GROUND OK light on the front panel of the AC-6+ do not light up. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NILES IPOWER AC-6

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NILES IPOWER AC-6 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag