User manual NILFISK AUTO BOOSTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NILFISK AUTO BOOSTER. We hope that this NILFISK AUTO BOOSTER user guide will be useful to you.

Lastmanuals help download the user guide NILFISK AUTO BOOSTER.


Mode d'emploi NILFISK AUTO BOOSTER
Download

You may also download the following manuals related to this product:

   NILFISK AUTO BOOSTER OPERATING INSTRUCTIONS (6502 ko)

Manual abstract: user guide NILFISK AUTO BOOSTER

Detailed instructions for use are in the User's Guide.

[. . . ] AUTO BOOSTER E User manual Betriebsanleitung 107319149 f AUTO BOOSTER E Index 1 2 Safety precautions and warnings Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 2. 1 Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 2. 2 Operation elements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 3. 1 3. 2 3. 3 3. 4 3. 5 3. 6 3. 7 3. 8 Temperature conditions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] The coin selector is now tought to recognize and accept the Token as valid payment, and the value assigned to the Token depends on the chosen Teach Channel (see 4. 1. 4). Tokens and national coins can be used simultaneously, when their blocking switches are OFF. 15 AUTO BOOSTER E 4. 1. 4 Setting coin value on timer Locate the Timer board inside the AUTO BOOSTER's electric box. On the "Minimum Price" switches choose the minimum price to be paid for the AUTO BOOSTER to operate. On the "Time Setting" switches choose the time value you want to assign to the minimum price. Minimum price setting: Use pins to set minimum price to activate machine. Time setting: Use pins to set time value of coin/token. See coin table and example following. Factory programming interface. Interface and power supply to coiner. Interface to power supply and AUTO BOOSTER control. 16 AUTO BOOSTER E See below tables for European and Scandinavian coin selectors: EMP 8. 000. 00 v5/E/I/T Settings for EU Coin Selector Coin type Currency Pulses SW no. 0, 50 1, 00 2, 00 EUR EUR EUR 1 2 4 Select time value in Sec's for selected "minimum price" 1, 00 2, 00 5, 00 CHF CHF CHF 2 4 10 SW no. / minimum price) 3 40 4 80 5 160 6 320 7 640 8 1280 Price 1 0, 50 2 1, 00 3 2, 00 Timer T220 Pirce Setting: Select minimum price (basis for time setting) Minimum price switch 4 4, 00 5 8, 00 6 16, 00 7 32, 00 8 64, 00 0, 50 1, 00 2, 00 GBP GBP GBP 1 2 4 , CHF, £ , CHF, £ , CHF, £ , CHF, £ , CHF, £ , CHF, £ Example of setting in -country: Owner wants 2, 5 to be inserted before machine can start: Flip SW1 & SW3 (0, 50 + 2, 00 ) on "Minimum price switch". Owner wants to assign 10 minutes to the minimum price 2, 5 : Flip SW3, SW4, SW5 & SW6 (40+80+160+320=600 sec's = 10 minutes) on "Time Setting Switch". All other coin values will be adjusted proportionally by the timer - i. e. Owner also wants to use a token with an assigned value of 3 : As 1 corresponds to 2 impulses, 3 equals 6 impulses - so owner teaches "TK13C" to recognize the token (see how in sect. 4. 1. 3). TK11 TK12 TK13 TK14 TK15 TK16 A B C D E F 2 4 6 8 10 12 1 2 3 4 5 6 Minimum price setting: Use pins to set minimum price Time setting: Use pins to set time value of minimum price. 17 AUTO BOOSTER E EMP 8. 000. 00 v5/E/I/T Settings for Scandinavian Coin Selector Coin type Currency Pulses SW no. 5, 00 10, 00 20, 00 NOK NOK NOK 1 2 4 Price 1 0, 50 2 1, 00 3 2, 00 Timer T220 Pirce Setting: Select minimum price (basis for time setting) Minimum price switch 4 4, 00 5 8, 00 6 16, 00 7 32, 00 8 64, 00 Select time value in Sec's for selected "minimum price" 5, 00 10, 00 20, 00 DKK DKK DKK 2 4 10 SW no. / minimum price) 3 40 4 80 5 160 6 320 7 640 8 1280 5, 00 10, 00 SEK SEK 1 2 Example of setting in Norway: Owner wants 5 NOK to be inserted before machine can start: Flip SW2 & SW4 (1, 00 NOK + 4, 00 NOK on "Minimum price switch". Owner wants to assign 2 minutes 30 sec's to the minimum price of 5, 00 NOK. Flip SW1, SW2, SW3 & SW4 (10+20+40+80 = 150 sec's = 2 min. 30 sec's) on "Time Setting Switch". All other coin values will be adjusted proportionally by the timer - i. e. 10 NOK will be 300 sec's, or 5 minutes. Owner also wants to use a token with an assigned value of 50 NOK: As 5 NOK corresponds to 1 impulse, 50 NOK equals 10 impulses - so owner teaches "TK15E" to recognize the token (see how in sect. 4. 1. 3). TK11 TK12 TK13 TK14 TK15 TK16 A B C D E F 1 2 4 8 10 12 5 10 20 40 50 60 DKK, NOK, SEK DKK, NOK, SEK DKK, NOK, SEK DKK, NOK, SEK DKK, NOK, SEK DKK, NOK, SEK 4. 1. 5 Maintenance The EMP 800 is an extraordinarily robust coin selector and operates relatively maintenance free. However, it should be cleaned at regular intervals especially if it is operating in an environment with high levels of dust, smoke or nicotine. The cleaning intervals are of course dependent on the level of air borne contaminants. Modest use with minimum contaminant levels indicates the need to clean the top of the coin path once a year. [. . . ] · Repair leak. Working pressure too low > Nozzle worn > Wrong spray lance > Nozzle partly clogged up No detergent > Detergent container empty > Filter in container clogged up Too much detergent Working pressure fluctuating > Wrong dosing > Air in the system > Detergent container empty > Water inlet filter clogged up No working pressure > Nozzle clogged up > Pre-nozzle clogged up > No inlet water > Water inlet filter clogged up Machine starts and stops 34 > Leaky hose/ pipeline/spray handle AUTO BOOSTER E Symptom Reason > Water shortage Action · Check the water supply open ?Check and clean the water inlet filter (see sect. 5. 4). 6. 2 Error messages If your AUTO BOOSTER does not heat the water although heating has been chosen for the actual program step, the reason may be that the fuel container is empty or that one of the overheat melting fuses has blown/cut out. The two fuses are located at the top of the boiler and MUST ONLY be exchanged by an Nilfisk-ALTO service technician. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NILFISK AUTO BOOSTER

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NILFISK AUTO BOOSTER will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag