Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NILFISK OZ 1. We hope that this NILFISK OZ 1 user guide will be useful to you.
Lastmanuals help download the user guide NILFISK OZ 1.
You may also download the following manuals related to this product:
NILFISK OZ 1 BROCHURE (777 ko)
NILFISK OZ 1 QUICK GUIDE (872 ko)
Manual abstract: user guide NILFISK OZ 1
Detailed instructions for use are in the User's Guide.
[. . . ] Ensure that all air flowing into the machine is clean. If the machine is not working as it should, has been dropped, damaged, left outdoors or flooded with water, return it to a service center. The appliance is not to be used by children or persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge, unless they have been given supervision or instruction. Supervised children shall not play with the appliance. [. . . ] Ozone treatment should be the final step in room maintenance. The air flowing into the machine must be clean and dry. Keep the filter at the fresh air intake clean.
TIME GUIDELINES:
This NIlfisk OZ 1 unit will control biological contamination and odor in areas up to 1133 m3. Many variables determine the actual length of time it takes to complete the decontamination with ozone. Some of the variables: l Type of odor causing contaminant, for example: mold, smoke, animal urine l Location in the space and size of the contaminated area l Size and configuration of the space l What types of articles are in the space -- furniture, carpet, hard floor, empty space Ozone has a half-life of about 15 minutes in open areas (can be hours in closed areas) and this increases with lower temperature and lower humidity. Use the following times as a basic guideline: Hotel room - 60 minutes Automobile - 20 to 30 minutes Fire and flood restoration: 12 to 72 hours It is always best to repeat the process if treatment did not resolve the problem rather than treating an area for longer than you believe it will take. Wait two hours after the treatment has ended before entering the space to ventilate. Allow the space to ventilate for one hour (minimum) before re-inhabiting the space.
NOTE: Ozone is a toxic gas. Follow all safety precautions
DO NOT INHALE FUMES
4
OPERATION: For buildings:
1. Make certain all people, pets, and plants are out of area. Ensure that the filter in front of the clean air intake is installed and is clean. Place the Nilfisk OZ 1 on a shelf, cabinet, or tabletop as high as possible in the area to be treated. Ozone is slightly heavier than air, so it will naturally drift down. If the treatment area is large or is divided into different spaces, the use of fans to gently move the ozone around can be helpful. Plug the power cord into a power outlet. Timer Operation: Momentarily pressing the UP timer button for one second will increase the time setting by one minute at a time. Press the button for 1-3 seconds to change the time value by two minutes per second. Hold the button for longer than 3 seconds and the time setting will change in 20 minutes increments. The maximum time setting is 29:59 hours. After reaching the maximum time, if you continue to press the UP bottom, the timer will wrap back to 00:00 and then continue increasing. When the time is being decreased and it reaches 00:00, it will wrap to 29:59 and continue decreasing. Output Volume: Select the desired power level: 25%; 50%; 75% 100%. [. . . ] When treatment is complete, ventilate the car completely. Figure 1: Figure 2:
HOSE
CLAMP
FOAM
CAUTION: BE SURE TO KEEP THE AIR INTAKE FILTER CLEAN
6
3
OZ-1
4 2 5 7
1 6
8 9 20 10
7
12 11
D
13
14
G: IN E E RN T US OPL TS WAO NO ND PEPLAN
, OU LS AR IMA AN
LF NI
ISK
15
11A
16 11 18 17 19
March 2008
OZ-1
PART LIST 220 - 240V
ITEM 1 2 3 4 5 6 7 8 9 10 11 11A 12 13 14 15 16 17 18 19 20 QTY 1 1 1 1 1 1 1 1 1 1 1 1 3 1 1 1 1 1 1 1 1 1 PART No. 600701032 600701033 600701014 600701036 600701028 600701015 600701021 600701016 600701019 600701018 600701038 600701026 600701025 600701017 600701023 600701020 600701034 600701024 600701037 600701035 600400100 600701039 DESCRIPTION Power cord and retainer, EU Power cord and retainer, UK Fan kit Fan guards and filter kit Replacement filter kit (4 per kit) Control board with timer display kit Bezel and gasket kit Touch pad Circuit breaker Safety switch kit Machine body, empty Electrode chamber, complete Electrode pair Transformer kit Bottom plate kit Terminal block kit Label kit Wiring loom, 33mm total Wiring Connectors kit Hardware kit Hose and foam kit Fuse and holder kit
15. 04. 2008 8
TROUBLESHOOTING: CAUTION:
ALWAYS UNPLUG THE MACHINE BEFORE YOU DO ANY TROUBLESHOOTING IF THIS OCCURS -- CHECK THIS NO POWER Make sure the power cord is plugged into an operational outlet. Look at the circuit breaker on the bottom of the machine, to make sure it has not tripped. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE NILFISK OZ 1
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NILFISK OZ 1 will begin.