User manual NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION. We hope that this NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION user guide will be useful to you.

Lastmanuals help download the user guide NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION.


Mode d'emploi NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION
Download
Manual abstract: user guide NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION

Detailed instructions for use are in the User's Guide.

[. . . ] Remote Control Buttons Button Function Power ON ­ Press and release. Power OFF ­ Press & Hold for 2 seconds. CHECKS dispenser ­ Places dispenser's formula on remote's screen, checks dispenser's battery, displays if in BAT LOW state. TO SEND a saved formula ­ Press a PROG button, then press SEND. * HOME SCREEN shows day & time. [. . . ] (d) Press UP or DOWN arrows until correct number displays. Leave a zero in the left-hand column where appropriate (i. e. (e) When current day and time display (i. e. WED 18:30), press the ENTER button to save and exit. To exit without saving changes, press CLOCK again to display the CLOCK day and time (also called the Home Screen). HRS ( )( ) ml. - Mude uma fórmula HRS CHANGE a Formula - Formel Verändern - Changez une formule HRS HRS - Cambie una fórmula HRS - Cambi una formula 2 Sec. ml. oz. DELETE an Event - Einen Fall löschen -Supprimer un événement -Suprimir un acontecimiento -Cancellare un evento -Suprimir um evento Home Screen HRS HRS HRS 2 Sec. x 8888888:88DAYS . oz. CHECK Dispenser - Überprüfen des Dispensers - Vérifiez Le Distributeur - Compruebe El Dispensador - Controlli L'Erogatore - Verifique O Distribuidor HRS DAYS m) (1. 2 4 ft. f sight o line Hidden Prime Buttons ml. oz. PRIME Pump - Produkt Ausaugen - Amorcez la pompe - Prepare la bomba - Inneschi la pompa - Apronte a bomba 3. Making sure that the remote is powered on, has a clear lineof-sight, is within 4 ft. (1. 2 m) of the dispenser, AND displays the HOME screen, point the remote directly at the dispenser and either: (a) Press SEND to send the last program displayed on the screen, or (b) Press any PROG button that has a saved formula, then press SEND. A new remote contains the factory pre-set formula as the PROG 1 button. SET displays to indicate that programming is successful. Customized Programming Create custom formulas by reviewing a formula, adding or deleting events in the formula, then saving the revised formula to a PROG button. To add or delete events, you must first make the displayed formula "editable" by pressing the RIGHT ARROW and underscoring the DAY, TIME or DOSAGE. PROG 1 holds the factory pre-set formula. To avoid overwriting the factory pre-set, save additional custom formulas to the PROG 2 and PROG 3 buttons. A formula can be temporarily modified and sent to a dispenser without being saved. The temporary formula remains in the remote until another formula is used or the remote is powered off. NOTE · You can only edit or delete the event that you are currently viewing on the remote's screen. · Because each event is unique, each must be separately edited or deleted. Programming Navigation Buttons UP ARROW Increases / Moves Value Forward ENTER / SAVE LEFT ARROW Moves underscore back RIGHT ARROW Underscores next item 6. 2. 3 Review, Save and Exit Options DOWN ARROW Decreases / Moves Value Backward 6. 2 Create Custom Formulas 4. Troubleshooting 4. 1 COM BAD displays instead of SET The formula was NOT successfully downloaded. The most likely reasons are: · The remote is too far from the dispenser. [. . . ] NEW MON 09:00 8 OZ (or whichever is the first event in the current program). Press REVIEW to see all events in that formula. Pressing REVIEW will not show days that have no events programmed. 6. With DOSAGE still underscored, press ENTER to save that event. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual NOVA CONTROLS PROFLOWPROGRAMMINGINSTALLATION will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag