User manual OMRON 3G3JV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON 3G3JV. We hope that this OMRON 3G3JV user guide will be useful to you.

Lastmanuals help download the user guide OMRON 3G3JV.


Mode d'emploi OMRON 3G3JV
Download
Manual abstract: user guide OMRON 3G3JV

Detailed instructions for use are in the User's Guide.

[. . . ] Simple, Compact Inverters 3G3JV Series Note: Do not use this document to operate the Unit. OMRON Corporation FA Systems Division H. Q. 66 Matsumoto Mishima-city, Shizuoka 411-8511 Japan Tel:(81)55-977-9181 Fax:(81)55-977-9045 Regional Headquarters Authorized Distributor: OMRON EUROPE B. V. Wegalaan 67-69, NL-2132 JD Hoofddorp The Netherlands Tel:(31)2356-81-300/Fax:(31)2356-81-388 OMRON ELECTRONICS LLC 1 East Commerce Drive, Schaumburg, IL 60173 U. S. A. [. . . ] 3G3JV-A2j: 3 phase 200 to 230 V AC 3G3JV A2j: 3-phase 3G3JV-ABj: 3-phase 200 to 240 V AC 3G3JV-A4j: 3-phase 380 to 460 V AC The maximum output voltage corresponds to the input power supply voltage for the Inverter. Connect the DC reactor for suppressing harmonics to terminals +1 and +2. When driving the Inverter with DC power, input the DC power to terminals +1 and ­. (Terminal +1 is a positive terminal. ) Note 25 Specifications Control Circuit Terminals Symbol Input p S1 S2 S3 S4 S5 SC FS FR FC Output MA MB MC AM AC Name Forward/Stop Multi-function input 1 (S2) Multi-function input 2 (S3) Multi-function input 3 (S4) Multi-function input 4 (S5) Sequence input common Frequency reference power supply Frequency reference input Frequency reference common Multi-function contact output (Normally open) Multi-function contact output (Normally closed) Multi-function contact output common Analog monitor output Analog monitor output common Function Forward at ON. Set by parameter n36 (Reverse/Stop) Set by parameter n37 (Fault reset) Set by parameter n38 (External fault: Normally open) Set by parameter n39 (Multistep reference 1) Common for S1 through S5 DC power supply for frequency reference use Input terminal for frequency reference use Common for frequency reference use Set by parameter n40 (during u g) running) Signal level Photocoupler p 8 mA at 24 V DC ( A (see note 2) 20 mA at 12 V DC 0 to 10 V DC (Input impedance = 20 k) ( pu peda ce 0 ) Relay output a at C 1 A max. at 250 V AC C Common for MA and MB use Set by parameter n44 (Output frequency) Common for AM use 2 mA max. Functions in parentheses are default settings. The input method is set to NPN by default, so use the GND common for wiring. An external power supply is not required. When a power supply is used and a common on the plus side is used for wiring, set SW7 to PNP and use a 24-V DC (±10%) power supply. 26 Dimensions Dimensions 3G3JV-A2001 to 3G3JV-A2007 (0. 1 to 0. 75 kW) 3-phase 200-V AC Input 3G3JV-AB001 to 3G3JV-AB004 (0. 1 to 0. 4 kW) Single-phase 200-V AC Input 3G3JV-A2015 to 3G3JV-A2022 (1. 5 to 2. 2 kW) 3-phase 200-V AC Input 3G3JV-AB007 to 3G3JV-AB015 (0. 75 to 1. 5 kW) Single-phase 200-V AC Input 3G3JV-A4002 to 3G3JV-A4022 (0. 2 to 2. 2 kW) 3-phase 400-V AC Input Two, 5-dia. holes t Rated voltage Model 3G3JV3G3JV A2001 A2002 A2004 A2007 Dimensions (mm) D t 3 3 5 5 3 3 5 70 70 102 122 70 70 112 Weight (kg) Rated voltage Model 3G3JV3G3JV A2015 A2022 AB007 AB015 A4002 A4004 A4007 A4015 A4022 Dimensions (mm) D 129 154 129 154 81 99 129 154 154 Weight (kg) 3-phase 200 V AC p Approx. 0. 9 3-phase 200 V AC p Single-phase 200 V AC gp 3-phase 400 V AC p Approx. 1. 5 Single-phase 200 V AC gp AB001 AB002 AB004 3G3JV-A2037 (3. 7 kW) 3-phase 200-V AC Input 3G3JV-A4037 (3. 7 kW) 3-phase 400-V AC Input Rated voltage Model 3G3JV3G3JV A2037 A4037 Dimensions (mm) D 161 161 Weight (kg) 3-phase 200 V AC 3-phase 400 V AC Approx. 2. 1 27 Standard Connections Standard Connections DC reactor (optional) Noise Filter 3-phase 200 V AC Single-phase 200 V AC (see note 1) 3-phase 400 V AC Forward/Stop Multi-function input 1 (S2) Multi-function input 2 (S3) Multi-function contact output NO NC Common Multi-function input 3 (S4) Multi-function input 4 (S5) Sequence input common Frequency reference power supply 20 mA at +12 V FREQ adjuster (2 k, 1/4 W min. ) Frequency reference input Frequency reference common Analog monitor output Analog monitor output common Note: 1. Connect single-phase 200 V AC to terminals R/L1 and S/L2 of the 3G3JV-ABj. The braking resistor cannot be connected because no braking transistor is incorporated. Input Method Selection Switches SW7 and SW8, both of which are located above the control circuit terminals, are used for input method selection. Remove the front cover and optional cover to use these switches. Selector Control circuit terminal block Sequence Input Method Selection By using SW7, NPN or PNP input can be selected as shown below. 24 V (Factory setting) S1 to 5 24 V DC (±10%) S1 to 5 Frequency Reference Input Method Selection By using SW8, frequency reference voltage or current input can be selected. Parameter settings are required together with the selection of the frequency reference input method. Frequency reference input method Voltage input Current input V (OFF) I (ON) SW8 setting Frequency reference selection (parameter n03) Set value 2 Set value 3 or 4 28 Protective and Diagnostic Functions Fault Detection (Fatal Error) The Inverter will detect the following faults if the Inverter or motor burns or the internal circuitry of the Inverter malfunctions. When the Inverter detects a fault, the fault code will be displayed on the Digital Operator, the fault contact output will operate, and the Inverter output will be shut off causing the motor to coast to a stop. The stopping method can be selected for some faults, and the selected stopping method will be used with these faults. If a fault has occurred, refer to the following table to identify and correct the cause of the fault. Use one of the following methods to reset the fault after restarting the Inverter. [. . . ] The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products. · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. · Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON 3G3JV

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON 3G3JV will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag