[. . . ] (at 500 VDC) between power supply section, electrode section, and contact section 2, 000 VAC 50/60 Hz for 1 min between power source section, electrode section, and contact section Vibration of 10 to 55 Hz and acceleration of 50 m/s2 for 5 min. 10 times each in X, Y, and Z directions 100 m/s2 3 times each in 6 directions on 3 axes Overvoltage Category II, Pollution Degree 2 EN61010-1 EN61326 Industrial applications Operating resistance Reset resistance Response time Cable length Control output Indicators Ambient temperature Ambient humidity Elevation Insulation resistance Dielectric strength Vibration resistance Shock resistance Installation environment Safety standards EMC 2 Conductive Level Controller 61F-D21T-V1 Cat. N149-E1-03A Connections Operation Diagram PWR E2-E3 E1-E3 A2 OFF RY:SW1 ON E3 E2 E1 14 E1 E2 E3 11 Wiring Diagram 24 VAC/DC 100-240 VAC A1 Control 12 output Automatic Water Supply and Drainage Control 1. Drainage (RY-SW1 ON) P Pump OFF Pump ON E1 Indicator OFF E1 Indicator ON Pump ON E2 E3 Indicator ON E2 E3 Indicator OFF P Pump OFF The pump stops when the water level reaches E1 (indicator OFF) and starts when the water level drops below E2 (indicator ON). The pump starts when the water level reaches E1 (indicator ON) and stops when the water level drops below E2 (indicator OFF). Cat. [. . . ] Recommended torque: 0. 49 N·m Assured torque: 0. 59 N·m · When using the product, ensure that the wiring is correct before turning on the power. · Use a power-supply voltage that is within the range of specifications. · Use the control source and power supply or power lines that provide inputs with appropriate specifications. · Do not install near heat-generating devices (coils, or devices that use coils). · Be sure to confirm terminal numbers for correct wiring. Double-check materials such as connection charts and circuit diagrams. · Properly ground the grounding terminal. Ensure that the common electrode terminal has been properly grounded. Doing so can alleviate effects from noise. · If electrodes make contact with liquid, purchase and use a separator to prevent such contact. · Keep appropriate distance from devices that generate highfrequency noise (e. g. , high-frequency welders, electronic sewing machines). · Do not turn a setting volume beyond the scope of movement. · Do not connect anything to unused terminals. · Use SELV power supply with over load protection function for DC power supply. The insulation of SELV power supply must be a double or reinforced between input and output. and 42. 4 V at peak, or use the power supply of 60 V DC max. Recommended power supply: type S8VS-06024@ (OMRON made) Precautions for Correct Use For Proper Use 1. Make sure to use setting values appropriate for the controlled object. Failure to do so can cause unintended operation, and may result in accident or corruption of the product. When discarding, properly dispose of the product as industrial waste. Only use this product within a board whose structure allows no possibility for fire to escape. To avoid damage to the exterior of the product, do not use organic solvents (thinner, benzene) or agents with strong alkalinity or acidity. About Installation 1. [. . . ] Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON 61F-D21T-V1

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON 61F-D21T-V1 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag