[. . . ] W462-E1-06
SYSMAC CP Series CP1L-L_0D_ CP1L-M_0D_
CP1L CPU Unit
OPERATION MANUAL
CP1L-L10D@-@ CP1L-L14D@-@ CP1L-L20D@-@ CP1L-M30D@-@ CP1L-M40D@-@ CP1L-M60D@-@
CP1L CPU Unit
Operation Manual
Revised March 2009
iv
Notice:
OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property.
!DANGER
!WARNING
!Caution
Indicates an imminently hazardous situation which, if not avoided, will result in death or serious injury. [. . . ] The FAL Error Flag (A402. 15) or FALS Error Flag (A401. 06) is turned ON. The corresponding error code is written to A400. The error code and time of occurrence are stored in the Error Log. The error indicator on the front of the CPU Unit will flash or light. If FAL(006) has been executed, the CPU Unit will continue operating. If FALS(007) has been executed, the CPU Unit will stop operating. (Program execution will stop. )
413
Failure Diagnosis Functions
Operation of FAL(006)
A FAL 002 #0000
Section 6-8
When execution condition A goes ON, an error with FAL number 002 is generated, A402. 15 (FAL Error Flag) is turned ON, and A360. 02 (FAL Number 002 Flag) is turned ON. Errors generated by FAL(006) can be cleared by executing FAL(006) with FAL number 00 or performing the error read/clear operation from the CX-Programmer. Operation of FALS(007)
B FALS 003 #0000
When execution condition B goes ON, an error with FALS number 003 is generated, and A401. 06 (FALS Error Flag) is turned ON. Errors generated by FAL(006) can be cleared by eliminating the cause of the error and performing the error read/clear operation from the CX-Programmer.
6-8-2
Failure Point Detection: FPD(269)
FPD(269) performs time monitoring and logic diagnosis. The time monitoring function generates a non-fatal error if the diagnostic output isn't turned ON within the specified monitoring time. The logic diagnosis function indicates which input is preventing the diagnostic output from being turned ON.
Time Monitoring Function
FPD(269) starts timing when it is executed and turns ON the Carry Flag if the diagnostic output isn't turned ON within the specified monitoring time. The Carry Flag can be programmed as the execution condition for an error processing block. Also, FPD(269) can be programmed to generate a non-fatal FAL error with the desired FAL number. When an FAL error is generated, a preset message will be registered and can be displayed on the CX-Programmer. FPD(269) can be set to output the results of logic diagnosis (the address of the bit preventing the diagnostic output from being turned ON) just before the message. The teaching function can be used to automatically determine the actual time required for the diagnostic output to go ON and set the monitoring time.
Logic Diagnosis Function
FPD(269) determines which input bit is causing the diagnostic output to remain OFF and outputs the result. The output can be set to bit address output (PLC memory address) or message output (ASCII). If bit address output is selected, the PLC memory address of the bit can be transferred to an Index Register and the Index Register can be indirectly addressed in later processing.
414
Failure Diagnosis Functions
Section 6-8
If the message output is selected, an error message can be displayed on the CX-Programmer at the same time as a FAL error is generated for time monitoring.
FPD(269) execution condition A
FPD #0004 &100
Carry Flag (ON for timeout) Control data (FAL 004, bit address output for failure) Monitoring time (0. 1-s units): 10 s First register word of diagnostics output
D01000
Error-processing block
C (Diagnostic output) Logic diagnosis execution condition B
Time Monitoring Monitors whether output C goes ON with 10 seconds after input A. If C doesn't go ON within 10 seconds, a failure is detected and the Carry Flag is turned ON. The Carry Flag executes the error-processing block. Also, an FAL error (non-fatal error) with FAL number 004 is generated. [. . . ] tion 1-1 Search Direction CW
Origin Input Signal (Y CPU Units) 1-6 1-7 Proximity Input Signal Search High Speed NC 0 pps (disabled)
NC (line driver) NO (line driver) NC NO 0 pps : 100, 000 pps
2 hex 3 hex
At start of operation At start of operation
268 261 and 260
04 to 07 00 to 15
0 hex 1 hex 0000 0001 hex : 0001 86A0 hex 000F 4240 hex
1-8
Search Proximity Speed
0 pps (disabled)
1 pps : 100, 000 pps
At start of operation
263 and 262
00 to 15
0000 0001 hex : 0001 86A0 hex 000F 4240 hex
1-9
Search Compensation Value
0 pps
-2, 147, 483, 648 : 0 : +2, 147, 483, 647
At start of operation
265 and 264
00 to 15
8000 0000 hex : 0000 0000 hex : 7FFF FFFF hex
1-10
Search Accelera- 0 (disabled) tion Ratio
1 (pulses/4 ms) : 65, 535 (pulses/4 ms) 1 (pulses/4 ms) : 65, 535 (pulses/4 ms) 0 ms : 9, 999 ms
At start of operation
266
00 to 15
0001 hex : FFFF hex 0001 hex : FFFF hex 0000 hex : 270F hex
1-11
Search Decelera- 0 (disabled) tion Ratio
At start of operation
267
00 to 15
1-12
Positioning Moni- 0 ms tor Time
At start of operation
269
00 to 15
757
PLC Setup
Appendix G
Origin Return Settings
Name 1 Speed Default 0 pps (disabled) 1 pps : 100, 000 pps Settings When setting is read by CPU Unit At start of operation Internal address 271 and 270 Bits 00 to 15 Settings 0000 0001 hex : 0001 86A0 hex 000F 4240 hex At start of operation 272 00 to 15 0001Hex : FFFF hex At start of operation 273 00 to 15 0001 hex : FFFF hex
2
Acceleration Ratio
0 (disabled)
1 (pulses/4 ms) : 65535 (pulses/4 ms)
3
Deceleration Ratio
0 (disabled)
1 (pulses/4 ms) : 65535 (pulses/4 ms)
758
PLC Setup
Appendix G
Pulse Output 1 Settings
Base Settings
Name 1 Default Hold Undefined Search Only Always NC 0 pps (disabled) NC NO 4 Search/Return Initial Speed 0 pps : 100, 000 pps At start of operation 277 and 276 When power is turned ON At start of operation 274 286 Settings When setting is read by CPU Unit At start of operation Internal address 286 Bits 12 to 15 04 to 07 00 to 03 00 to 15 Settings 0 hex 1 hex 0 hex 1 hex 0 hex 1 hex 0000 0001 hex : 0001 86A0 hex 000F 4240 hex When power is turned ON 274 12 to 15 0 hex 1 hex Undefined Origin (oper- Hold ation for limit signal turning ON) Limited Input Signal Operation Limit Input Signal Search Only
2 3
5
Speed Curve
Trapezium
Trapezium S-shaped
759
PLC Setup
Appendix G
Define Origin Operation Settings: Origin Search Settings
Name 1 Default Settings Do not use. CW CCW 1-2 Detection Method Method 0 Method 0 Method 1 Method 2 1-3 1-4 Search Operation Inverse 1 Operation Mode Mode 0 Inverse 1 Inverse 2 Mode 0 Mode 1 Mode 2 1-5 Origin Input Sig- NC nal (X/XA CPU Units) NC NO Unit version 1. 0 and earlier: At start of operation Unit version 1. 1 and later: When power is turned ON At start of operation 286 08 to 11 At start of operation 275 At start of operation 275 04 to 07 00 to 03 At start of operation 275 When setting is read by CPU Unit When power is turned ON At start of operation Internal address 274 275 Bits 00 to 03 12 to 15 08 to 11 Settings 0 hex 1 hex 0 hex 1 hex 0 hex 1 hex 2 hex 0 hex 1 hex 0 hex 1 hex 2 hex 0 hex 1 hex Use define origin opera- Do not use. tion 1-1 Search Direction CW
Origin Input Signal (Y CPU Units) 1-6 1-7 Proximity Input Signal Search High Speed NC 0 pps (disabled)
NC (line driver) NO (line driver) NC NO 0 pps : 100, 000 pps
2 hex 3 hex
At start of operation At start of operation
286 279 and 278
04 to 07 00 to 15
0 hex 1 hex 0000 0001 hex : 0001 86A0 hex 000F 4240 hex
1-8
Search Proximity Speed
0 pps (disabled)
1 pps : 100, 000 pps
At start of operation
281 and 280
00 to 15
0000 0001 hex : 0001 86A0 hex 000F 4240 hex
1-9
Search Compensation Value
0 pps
-2, 147, 483, 648 : 0 : +2, 147, 483, 647
At start of operation
283 and 282
00 to 15
8000 0000 hex : 0000 0000 hex : 7FFF FFFF hex
1-10
Search Accelera- 0 (disabled) tion Ratio
1 (pulses/4 ms) : 65, 535 (pulses/4 ms) 1 (pulses/4 ms) : 65, 535 (pulses/4 ms) 0 ms : 9, 999 ms
At start of operation
284
00 to 15
0001 hex : FFFF hex 0001 hex : FFFF hex 0000 hex : 270F hex
1-11
Search Decelera- 0 (disabled) tion Ratio
At start of operation
285
00 to 15
1-12
Positioning Moni- 0 ms tor Time
At start of operation
287
00 to 15
760
PLC Setup
Appendix G
Origin Return Settings
Name 1 Speed Default 0 pps (disabled) 1 pps : 100, 000 pps Settings When setting is read by CPU Unit At start of operation Internal address 289 and 288 Bits 00 to 15 Settings 0000 0001 hex : 0001 86A0 hex 000F 4240 hex At start of operation 290 00 to 15 0001Hex : FFFF hex At start of operation 291 00 to 15 0001 hex : FFFF hex
2
Acceleration Ratio
0 (disabled)
1 (pulses/4 ms) : 65535 (pulses/4 ms)
3
Deceleration Ratio
0 (disabled)
1 (pulses/4 ms) : 65535 (pulses/4 ms)
Inverter Positioning 0
Basic Settings
Name 1 2 Default Use Do not use Gain 0: 10 (0. 1 incre- 0: 10 (0. 1 increments) ments) 1 (0. 1 increments) : 65, 535 (0. 1 increments) 3 In-position range 0: 1 0: 1 1 : 65, 535 4 Min. output value 0: 1 0: 1 1 : 65, 535 5 Max. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CP1L CPU UNIT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.