Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON CS1D DUPLEX SYSTEM. We hope that this OMRON CS1D DUPLEX SYSTEM user guide will be useful to you.
Lastmanuals help download the user guide OMRON CS1D DUPLEX SYSTEM.
Manual abstract: user guide OMRON CS1D DUPLEX SYSTEM10-2009
Detailed instructions for use are in the User's Guide.
[. . . ] W405-E1-09
SYSMAC CS Series
CS1D-CPU_H CPU Units CS1D-CPU_S CPU Units CS1D-DPL01/02D Duplex Unit CS1D-PA/PD_ Power Supply Unit
CS1D Duplex System
OPERATION MANUAL
CS1D-CPUS CPU Units CS1D-DPL01/02D Duplex Unit CS1D-PA/PD@ Power Supply Unit CS1D Duplex System
Operation Manual
Revised October 2009
iv
Notice:
OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. [. . . ] ON while file data is being accessed in the right CPU Unit. Read-only ON when a Memory Card has been detected in the right Read-only CPU Unit. OFF when a Memory Card has not been detected.
File Memory Operation Flag
A34213
Accessing File Data Flag Memory Card Detected Flag
A34214 A34215
Other File Memory Information
Name Number of Items to Transfer Address A346 to A347 Description These words contain the number of words or fields remaining to be transferred (8-digit hexadecimal). For binary files (. IOM), the value is decremented for each word that is read. For text (. TXT) or CSV (. CSV) data, the value is decremented for each field that is read. Access Read-only
EM File Memory Starting Bank
A344
Contains the starting bank number of EM file memory (bank Read-only number of the first formatted bank). This number is read when starting to write data from a Memory Card. If the largest bank number for which there is an EM file for simple backup (BACKUPE@. IOM, where represents consecutive bank numbers) is the same as the largest bank number supported by the CPU Unit, the EM Area will be formatted as file memory using the value in A344. If the maximum bank numbers are different, the EM Area will be returned to it's unformatted (not file memory) status. The system automatically deleted the remainder of an EM Read-only file memory file that was being updated when a power interruption occurred. The system automatically deleted the remainder of a Mem- Read-only ory Card file that was being updated when a power interruption occurred. If a write for a simple backup operation fails, A397 will con- Read-only tain the Memory Card capacity that would have been required to complete the write operation. (This indicates that the Memory Card did not have the specified capacity when the write operation was started. ) 0001 to FFFF hex: Write error (value indicates required capacity from 1 to 65, 535 Kbytes). A397 will be cleared to 0000 hex when the write is completed successfully for a simple backup operation.
File Deletion Flags
A39506
A39507
Simple Backup Write Capacity A397
288
Auxiliary Area
Name Program Replacement End Code Address A65000 to A65007 Description
Section 8-11
Access
Replacement Error Flag
A65014
Normal End (i. e. , when A65014 is OFF) Read-only 01 hex: Program file (. OBJ) replaced. Error End (i. e. , when A65014 is ON) 00 hex: Fatal error 01 hex: Memory error 11 hex: Write-protected 12 hex: Program replacement password error 21 hex: No Memory Card 22 hex: No such file 23 hex: Specified file exceeds capacity (memory error). 31 hex: One of the following in progress: File memory operation User program write Operating mode change ON when the Replacement Start Bit (A65015) has been Read/write turned ON to replace the program, but there is an error. If the Replacement Start Bit is turned ON again, the Replacement Error Flag will be turned OFF. Program replacement starts when the Replacement Start Bit Read/write is turned ON if the Program Password (A651) is valid (A5A5 hex). Do not turn OFF the Replacement Start Bit during program replacement. When the power is turned ON or program replacement is completed, the Replacement Start Bit will be turned OFF, regardless of whether replacement was completed normally or in error. It is possible to confirm if program replacement is being executed by reading the Replacement Start Bit using a Programming Device, PT, or host computer. Store the password to replace a program. [. . . ] Page 394: Changed information on online Unit replacement. Page 407: Added new subsection with information on online Unit replacement without a Programming Device. Page 455: Added information on A09911 to table. Page 491: Added information on 009A to table. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON CS1D DUPLEX SYSTEM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON CS1D DUPLEX SYSTEM will begin.