User manual OMRON D40A-G9SX-NS BROCHURE

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON D40A-G9SX-NS. We hope that this OMRON D40A-G9SX-NS user guide will be useful to you.

Lastmanuals help download the user guide OMRON D40A-G9SX-NS.


Mode d'emploi OMRON D40A-G9SX-NS
Download

You may also download the following manuals related to this product:

   OMRON D40A-G9SX-NS DATASHEET (78 ko)

Manual abstract: user guide OMRON D40A-G9SX-NSBROCHURE

Detailed instructions for use are in the User's Guide.

[. . . ] Compact Non-Contact Door Switch/Flexible Safety Unit D40A/G9SX-NS CSM_D40A_G9SX-NS_DS_E_3_2 Electronic Detection Mechanism for Better Stability in Non-contact Door Switch Operation Be sure to read the "Safety Precautions" on page 24 and the "Precautions for All Safety Door Switches". Features Easy-to-see 2-Color Indicators Switch status is easy to see at a glance with these red/yellow LED indicators. Mount from Either Side Mount from whichever side provides the easiest wiring path to enable mounting to all types of doors. Red: Open door detected. Yellow: Closed door detected. Not lit: Power OFF or failure Swinging doors Sliding doors Small Actuator An actuator that is smaller than the switch saves space, even inside the door. Even when mounted with an L-bracket, the actuator's height will not hinder installation or operation. Compact Switch Actuator Connect Up to 30 Switches to a Single Controller Reduce costs by connecting up to 30 Switches to a single Controller. Up to 30 Switches 1 D40A/G9SX-NS Solves Conventional Switch Issues to Provide Stable Detection Issue 1 The Switch does not accurately detect the door when it is closed slowly, resulting in an error. Conventional switch Door closed slowly. An error can occur if the door is closed slowly with conventional switches. Solution 1 Conventional Switches Slow The D40A does not use reed switches and provides stable detection with electronic switches. Slow If the switching timing of reed switch contacts 1 and 2 varies too much, the Controller detects an error and turns OFF the output to maintain safety. Note: The figure is intended only as an illustration. Detects slow rotating operation. Magnet Magnet Reed switch contacts Reed switch contacts Stable Detection with the D40A's New System Error Issue 2 It is nearly impossible to tell which door is open in a multi-door application. If an error occurs. . . The system cannot be started because the Controller has turned OFF the output even though all doors appear to be closed. [. . . ] Replace with a new product. T1 flashes 1. Error in the wiring of safety input 1 2. Incorrect setting of cross fault detection input 3. Failure of the circuit of safety input 1 3. Error in the wiring of safety input 2 2. Incorrect setting of cross fault detection input 3. Failure of the circuit of safety input 2 3. Error in the wiring of Non-contact Door Switch input 2. Error in the wiring of Non-contact Door Switch inputs in series connections. Failure of the internal circuits of Non-contact Door Switch inputs 4. Failure of the Non-contact Door Switch 1. Error in the wiring of feedback/reset input. Failure of the circuit of feedback/ reset input 1. Improper feedback signals from Expansion Unit 2. Abnormal supply voltage to Expansion Unit 3. Failure of the circuit of safety relay contact outputs 1. Error in the wiring of instantaneous safety outputs 2. Failure of the circuit of instantaneous safety outputs 3. Error in the wiring of the logical AND connection output 4. Failure of the circuit of the logical AND connection output 5. Error in the wiring of the auxiliary monitor output 6. Impermissible high ambient temperature 1. [. . . ] Input the contactor's NC signal between T31 and T32 (manual reset) or between T31 and T33 (auto reset). Refer to "Application Examples" on page 22. The A2 terminal must be grounded. Approved Standards D40A-@/G9SX-NS@/G9SX-NSA@ · Approved by TÜV SÜD EN 50178 EN 1088 IEC/EN 60204-1 EN 954-1 Cat. 3 IEC/EN 61508 SIL3 IEC/EN 60947-5-2 IEC/EN 60947-5-3 PDF-M · Approved by UL UL 508 · CAN/CSA C22. 2 No. 14 · KOSHA certification 27 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON D40A-G9SX-NS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON D40A-G9SX-NS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag