Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON D4B-N. We hope that this OMRON D4B-N user guide will be useful to you.
Lastmanuals help download the user guide OMRON D4B-N.
Detailed instructions for use are in the User's Guide.
[. . . ] Safety Limit Switch
D4B-#N
· Snap-action or slow-action contact for accurate switching with safe operation via a direct opening mechanism with metal deposition between mating contacts. · Two sets of contacts: one (NC) for safety category circuit and the other (NO) for control circuit. · Contacts opened by direct opening mechanism (NC contacts only), thus preventing faulty operation due to factors such as metal deposition. · Wide standard operating temperature range: 40°C to 80°C (standard type). [. . . ] x 6. 6 resin roller
M5 x 12 Allen-head bolt 31. 5R Operating position indicator (see note) 40 to 42
Six, 5. 3-dia. mounting holes Four, M3. 5 x 10 cover mounting screws
Four, M3. 5 x 24. 5 head mounting screws
Two, caps
Cover
Three, Conduit
Two, 5 +0. 15/0-dia. holes (depth: 6)
Note: The lever can be set to any desired position by turning the operating position indicator.
Adjustable Roller Lever D4B-##16N
19 dia. x 7 resin roller
25 to 89R
Operating position indicator (see note)
40 to 42 M5 x 16 Allen-head bolts
Four, M3. 5 x 24. 5 head mounting screws
Six, 5. 3-dia. Mounting holes 66. 4
Four, M3. 5 x 10 Cover mounting screws
Two, caps
Cover
Two, 5 +0. 15/0-dia. holes (depth: 6) Three, Conduit
Note: The lever can be set to any desired position by turning the operating position indicator.
Adjustable Rod Lever D4B-##17N
3 dia. Operating position indicator (see note)
M5 x 12 40 to 42 Allen-head bolts
Four, M3. 5 x 24. 5 head mounting screws
Six, 5. 3-dia. mounting holes Four, M3. 5 x 10 cover mounting screws Two, caps Cover
Three, Conduit
Two, 5 +0. 15/0-dia. holes (depth: 6)
Note: The lever can be set to any desired position by turning the operating position indicator.
G-252
Safety Sensors / Components
Top Plunger D4B-##70N
safety limit switch, mechanical form lock
40 to 42
9. 2 dia. Stainless steel plunger
Four, M3. 5 x 19. 5 head mounting screws
Six, 5. 3-dia. mounting holes
Four, M3. 5 x 10 cover mounting screws
Two, caps
Cover Two, 5 +0. 15/0-dia. holes (depth: 6)
Three, Conduit
Top Roller Plunger D4B-##71N
safety limit switch, mechanical form lock
12. 7 dia. x 4. 8 stainless steel roller
9. 2 dia.
Four, M3. 5 x 19. 5 head mounting screws
40 to 42
Six, 5. 3-dia. mounting screws
Four, M3. 5 x 10 cover mounting screws
Two, caps Cover Two, 5 +0. 15/0-dia. holes (depth: 6)
Three, Conduit
Stainless steel coil spring
Coil Spring D4B-##81N
18. 2 dia. 40 to 42
The Switch can be actuated to all directions except to the axis center
(40) (see note) 6. 6 dia.
Seal cap Four, M3. 5 x 7 head mounting screws Six, 5. 3-dia. mounting holes
Four, M3. 5 x 10 cover mounting screws
Two, caps Cover
Three, Conduit
Two, 5 +0. 15/0-dia. holes (depth: 6) Note: Set the spring so that the dog comes in contact at a point 40 mm from the tip.
Plastic Rod D4B-##87N
Plastic rod The Switch can be actuated to all directions except to the axis center.
6. 6 dia. 201. 9±1. 2 40 to 42 Seal cap Four, M3. 5 x 7 head mounting screws Six, 5. 3-dia. mounting holes Four, M3. 5 x 10 cover mounting screws Two, caps Cover
Three, Conduit
Two, 5 +0. 15/0-dia. holes (depth: 6) Note: Set the spring so that the dog comes in contact at a point 40 mm from the tip.
D4B-@N
G-253
D4B-@N
(40) (see note)
Levers
Roller Lever D4B-0001N
mechanical form lock
Adjustable Roller Lever D4B-0006N
19 dia. x 7 nylon roller
26 20. 2 12. 8
Adjustable Rod Lever D4B-0007N
3 dia. [. . . ] Make sure that the lever engages with the operating position indicator plate securely so that the lever will not slip.
Changes in Head Mounting Position
By removing the screws on the four corners of the head, the head can be reset in any of four directions. Make sure that no foreign materials will penetrate through the head.
Note: Apply a tightening torque of 0. 78 to 0. 88 N·m to conduit models.
G-256
Safety Sensors / Components
CW, CCW or Two-way Operation
The head of Side Rotary Switches can be converted in seconds to CW, CCW, or two-way operation. The conversion procedure follows.
Operating position mark (arrow)
Correct
Crimp terminal
Incorrect
Crimp terminal
Head cover (Push and rotate)
Procedure
1. Dismount the head by loosening the four screws that secure it. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON D4B-N
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON D4B-N will begin.