[. . . ] · The mounting direction of the head can be changed to allow the Operation Key to be inserted from four directions. · Metric conduit types available
Model Number Structure
Model Number Legend
Switch D4BL 1 2 3 4
5
2. Built-in Switch (with Safety Switch and Lock Monitor Switch Contacts) C: 1NC/1NO (slow-action) + 1NC (slow-action) D: 2NC (slow-action) + 1NC (slow-action) 3. Head Mounting Direction R: Four mounting directions possible (right-side mounting at shipping)
5. [. . . ] Orange: Lights when the solenoid turns ON. Green: Lights when the door opens.
(Power supply side)
2. Orange: Lights when the solenoid turns ON. Green: Lights when power turns ON.
(Power supply side)
E1 (+) 11 12 31 32 11 12 31 32
E1 (+)
Solenoid
23 24 E2 (-) 23 24
Solenoid
E2 (-)
LED (orange)
LED (orange)
LED (green)
LED (green)
Auxiliary circuit (monitor circuit)
Safety circuit
(Ground side)
Auxiliary circuit (monitor circuit)
Safety circuit
(Ground side)
3. Orange: Lights when the solenoid turns ON. Green: Lights when door closes.
(Power supply side)
4. Orange: Lights when the solenoid turns ON. Green: Lights when power turns ON.
(Power supply side)
E1 (+) 11 12 31 32 11 12 31 32
E1 (+)
Solenoid
21 22
LED (orange)
Solenoid
E2 (-) 21 22
LED (orange)
E2 (-)
LED (green)
LED (green)
Auxiliary circuit (monitor circuit)
Safety circuit
(Ground side)
Auxiliary circuit (monitor circuit)
Safety circuit
(Ground side)
F3SL
G-189
D4BL
Nomenclature
D4BL-#C##-#
Operation Key Lock plate Auxiliary release key Lock monitor switch Solenoid Rotating drum Operation plunger Seal ring (NBR) Auxiliary plunger Seal packing (NBR) Rotating lever
D4BL-#D##-#
Operation Key Lock plate Auxiliary release key Lock monitor switch Solenoid Rotating drum Operation plunger Seal ring (NBR) Auxiliary plunger Seal packing (NBR) Rotating lever
Safety switch
Safety switch
Seal packing (NBR) Conduit opening Conduit opening (Pull out (Pull out horizontally) vertically)
Seal packing (NBR)
Conduit opening Connection (Pull out terminal M3. 5 horizontally)
Ground terminal M3. 5
Connection terminal M3. 5
Ground terminal M3. 5
Conduit opening (Pull out vertically)
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated. Unless otherwise specified, a tolerance of ±0. 4 mm applies to all dimensions.
Switches
D4BL-####-#
(116. 5) Red 15 10 7 Lock protection cap Four, 5. 3 dia. mounting holes Four, M4 cover clamping screws Cover Four, M3. 5 head clamping screws 31. 5 17
34. 2
37. 5
(123. 5) 74±0. 1
86+1 0
6. 8 Conduit opening
100±0. 1 112+1 0
Indicators
5. 5
16 39. 6
46. 3
Conduit opening
Operating Characteristics D4BL-#### Key insertion force 19. 61 N max. Movement before being locked 15 mm max.
G-190
Safety Sensors / Components
Operation Keys
Horizontal Mounting D4BL-K1
Red
Vertical Mounting D4BL-K2
Red
78. 7 40. 7 12
53. 7
20±0. 15
Long mounting hole
7. 3 15
13
5. 3 x 7. 3 long mounting hole
25. 8 15. 6
25. 8 15. 6 Two, 2. 65R
36 11. 8 5. 6 5. 3 5. 3 2. 6 7. 5
40±0. 15 52. 4
36
20
5. 3 11. 9 7. 5 20
11. 8 4 dia. 2. 6
Adjustable Mounting (Horizontal) D4BL-K3
Red 40 12 20
26 40 Red
30±0. 15
(80. 7) 36 11. 8 30 5. 6 2. 6 19. 5±0. 1 (37. 8)
5. 3 dia. 4 dia.
17. 5
34. 6
M4 Allen-head bolt
F3SL
G-191
D4BL
With Operation Key Inserted
Horizontal Mounting D4BL + D4BL-K1
Red Horizontal direction Operation Key insertion radius R 1200 53. 5 min. (20±0. 15) (41) Vertical direction Operation Key insertion radius R 1000
(35)
Vertical Mounting D4BL + D4BL-K2
Red 54. 5 min. (41) (13) (41) Horizontal direction Operation Key insertion radius R 1200 54. 5 min. 58 max.
Vertical direction Operation Key insertion radius R 1000
(40±0. 15)
(35)
Adjustable Mounting (Horizontal) D4BL + D4BL-K3
Red Horizontal direction Operation Key insertion radius R 250 81. 5 min. (41) Vertical direction Operation Key insertion radius R 1000
(30±0. 15)
(35)
Note: 1. Unless otherwise specified, a tolerance of ±0. 4 mm applies to all dimensions. In the above diagrams, the Operation Key is inserted from the front.
G-192
Safety Sensors / Components
Precautions
Do not insert the Operation Key to the Switch with the door open. Before using the machine, be sure to remove the shock-absorbing damper, which is provided before shipping. Otherwise the machine may start operating and injury may be caused. [. . . ] Tighten the connector to a torque of 1. 77 to 2. 16 N·m. Connect the indicator unit after connecting the seven-conductor cable.
Cable Connection Example
1. Connect the wires to the terminals in the order shown below for wiring efficiency.
Tighten each wired terminal clockwise to a torque of 0. 59 to 0. 78 N·m.
Twist the wire two or three times and make sure that no bare wire exists outside the terminal when tightening the terminal.
Terminal no. E1 E2 31 12 23 (21) 24 (22)
Lp (mm) 30±2 35±2 45±2 55±2 65±2 70±2 90±2
Lv (mm) 80±2 75±2 60±2 50±2 45±2 35±2 50±2
a (mm)
2. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON D4BL
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.