[. . . ] 100 to 240 VAC (45 to 264 VAC), 50/60 Hz 50/60 Hz AC Limit switches D5C-1A@0
Touch Switch
D5C
1
Model Dielectric strength
DC D5C-1D@0
AC D5C-1A@0
1, 000 VAC, 50/60 Hz for 1 min between current-car- 2, 000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal rying metal parts and non-current-carrying metal parts parts 1, 000 VAC Level 3 (IEC947-5-1) Class II 175 D (IEC335) 10 to 55 Hz, 1. 5-mm double amplitude 1, 000 m/s2 min. Operating: 25°C to 70°C (with no icing) 95% max. 120 g (in case of D5C-1ASO)
Rated insulation voltage (Ui) Pollution degree (operating environment) Protection against electric shock Proof tracking index (PTI) Switch category Vibration resistance Shock resistance Ambient temperature Ambient humidity Weight
Output Circuit
D5C-1D@0 (DC Model)
Brown (Red) 4. 7 k Switch main circuit 2. 2 12 to 24 VDC
Load Black (White) Blue (Black)
D5C-1A@0 (AC Model)
Switch main circuit
Brown (White) Load 100 to 240 VAC Blue (Black)
Note: Color in ( ) denotes the old model.
Nomenclature
D5C-1DS0
Coil spring actuator (Stainless steel) LED operation indicator O ring Contactor Sensitivity adjuster Caution label
O ring
Actuator Case
Lead wire Washer Filled with glass epoxy Mounting nut
2
Touch Switch D5C
Engineering Data
Typical Examples
Temperature Characteristics of DC Models
D5C-1D@0 (24 VDC)
200
Temperature Characteristics of AC Models
D5C-1A@0 (100 VAC)
200 With sensitivity adjuster set to minimum sensitivity
Sensitivity (pF)
With sensitivity adjuster set to minimum sensitivity
100
Sensitivity (pF)
150
150
100 With sensitivity adjuster set to maximum sensitivity 50
50
With sensitivity adjuster set to maximum sensitivity
0
-40
-25
0
40
70 80
0
-40
-25
0
40
70 80
Temperature (°C)
Temperature (°C)
Voltage Characteristics of DC Model
D5C-1D@0 (at 25°C)
200
Voltage Characteristics of AC Model
D5C-1A@0 (at 25°C)
200 With sensitivity adjuster set to minimum sensitivity 150
150
With sensitivity adjuster set to minimum sensitivity
Sensitivity (pF)
Sensitivity (pF)
With sensitivity adjuster set to maximum sensitivity
100
100
50
50 With sensitivity adjuster set to maximum sensitivity 0 45 100 200 300
0
10
20
30
Voltage (V)
Voltage (V)
Touch Switch
D5C
3
Limit switches
Dimensions
Note: 1. All units are in millimeters unless otherwise indicated. [. . . ] However, limit the overtravel to within 20 mm from the free position. The force that pushes the actuator must not exceed 1. 96 N. Vinyl insulated round cord (oil- and shock-resistant type) 4 dia. , two cores × 0. 3 mm2. Use after removing the caution label.
Plunger D5C-1AP0
24 52 Overtravel 4 4 Caution label (see note 3) 4 dia. dia.
29 dia.
(See note 1)
M18 x 1 Two internal lock washers
LED Operation indicator Two clamping nuts (Width: 24; thickness: 4)
(See note 2)
Note: 1. The overtravel of the stainless steel plunger is within 3. 5 mm. Do not apply a force greater than 9. 8 N to the plunger. Vinyl insulated round cord (oil- and shock-resistant type) 4 dia. , two cores × 0. 3 mm2. Use after removing the caution label.
Free-attachment D5C-1AA0
(104) 76 28 Lock nut M4 x 0. 7 (see note 1) 14 4 52 4 Caution label (see note 3) 71 (3, 000)
4 dia. LED Operation indicator M18 x 1 Two internal Two clamping nuts lock washers (Width: 24; thickness: 4) 7. 1 dia. Limit the total length of actuator wire to 1 m or less. When mounting the Switch to a metal plate, do not exceed an area of 200 cm2. Vinyl insulated round cord (oil- and shock-resistant type) 4 dia. , two cores × 0. 3 mm2. Use after removing the caution label.
Touch Switch
D5C
5
Limit switches
Self-locking Two flat nut washers
Application Examples
Detection of Incorrectly Set Work Detection of Fine Wire or Thin Plate
Wire Press D5C D5C
Detection of Loose Screws
D5C 1. 0 mm
Steel plate
D5C
D5C
1. 0 mm
Precautions
Refer to the "Precautions for All Switches" in the separate Technical information about Basic Switches or Limit Switches.
CAUTION
Make sure that the antenna does not come into contact with the human body, otherwise an electric shock may be received.
Contact with Non-grounded Conductor The sensing object is equivalently grounded through capacitor C.
Nongrounded conductor 30 pF min. Generally, the conductor will be detectable if the ambient humidity is 60% to 70% and the surface area of the conductor is approximately 300 x 500 mm. D5C
Correct Use
Grounding of Antenna and Sensing Object (Size of Sensing Object)
Grounded Object
If the sensing object is the following grounded conductor, its size will not affect the operation of the D5C. Check for the presence of insulators sticking to the sensing object or the corrosion of the sensing object, however, so that the ground resistance will not exceed 3 k.
C: 30 pF min.
Conditions of Sensing Object
The detection of conductors (e. g. , iron, stainless steel, aluminum, and brass objects) poses no particular problem. A conductor coated with paint cannot be detected, however, because there is no electrical continuity between the antenna and the conductor. Non-conductive objects (e. g. , plastic, ceramic, glass, and cloth objects) can be detected by grounding them indirectly.
Contact with Grounded Conductor The sensing object is equivalently grounded through ground resistor R.
Grounded conductor 3 k max. D5C
Antenna
Shape and Extension
If a metal plate is used as an antenna by connecting it to the built-in or separated antenna of the D5C, the surface area of the metal plate must be 200 cm2 maximum (Fig. The antenna can be extended, provided that the total length of the antenna is 1 m maximum (Fig. 2) and that the bottom of the antenna is at least 10 cm (Fig. [. . . ] If the antenna is not tightened securely, the built-in contact may break. If an appropriate antenna is mounted to a free attachment model, hold the nut on the outer side with a wrench so that the nut will not move. Then tighten the nut on the inner side within a torque range of 0. 78 and 1. 18 N·m.
Wrench
The lead wire colors of the D5C have been changed in compliance with the latest applicable JIS standards. Colors in parentheses are previous ones.
Direction of turn
Antenna
Mounting
Do not tighten the nuts with excessive force. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON D5C
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.