User manual OMRON DEVICENET SAFETY 03-2008

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON DEVICENET SAFETY. We hope that this OMRON DEVICENET SAFETY user guide will be useful to you.

Lastmanuals help download the user guide OMRON DEVICENET SAFETY.


Mode d'emploi OMRON DEVICENET SAFETY
Download

You may also download the following manuals related to this product:

   OMRON DEVICENET SAFETY 04-2005 (1647 ko)
   OMRON DEVICENET SAFETY CONFIGURATION MANUAL 05-2005 (7692 ko)
   OMRON DEVICENET SAFETY SYSTEM CONFIGURATION 07-2009 (11715 ko)

Manual abstract: user guide OMRON DEVICENET SAFETY03-2008

Detailed instructions for use are in the User's Guide.

[. . . ] Z904-E1-04 DeviceNet Safety DST1-series Safety I/O Terminals OPERATION MANUAL DST1-series Safety I/O Terminals Operation Manual Revised March 2008 iv Notice: OMRON products are manufactured for use according to proper procedures by a qualified operator and only for the purposes described in this manual. The following conventions are used to indicate and classify precautions in this manual. Always heed the information provided with them. Failure to heed precautions can result in injury to people or damage to property. !DANGER !WARNING Indicates an imminently hazardous situation which, if not avoided, is likely to result in serious injury or may result in death. [. . . ] Goes into RUN Mode when safety I/O communications are started. Selecting this mode and executing the following operations causes startup in RUN Mode from that point onwards. · Locking the configuration · Turning OFF the power after changing to RUN Mode Safety I/O communications are not possible in this mode. 1972/01/01 After Establishing Safety I/O Connection --- Threshold Run Hours 0 to 429, 496, 729 hours --S Last Maintenance date Execution Mode (DST1XD0808SL-1 only) 1972/01/01 to 2038/01/19 After Establishing Safety I/O Connection Auto Execution IMPORTANT If the power is turned OFF in Idle Mode, the next operation will not start in RUN Mode even if Auto Execution is set as the execution mode and the configuration is locked. The power must be turned OFF in RUN Mode. IMPORTANT Safety I/O communications cannot be used when Auto Execution is set as the execution mode. To use safety I/O communications, set After Establishing Safety I/O Connection as the execution mode. 31 Editing Device Parameters Section 3-1 3-1-3 S Safety Input Parameters Value 0 to 126 ms (in increments of 6 ms) 0 to 126 ms (in increments of 6 ms) Not Used Test Pulse from Test Output Description Sets the OFF/ON delay time. Default 0 ms Parameter name Off On Delay S Off On Delay Sets the ON/OFF delay time. 0 ms S Safety Input Channel Mode The safety input is not used. (External input device not connected. ) Specifies connecting a device with a contact output in combination with a test output. When this mode is selected, select the test output to use for the test source and then set the test output mode to Pulse Test Output. When these settings are made, contact between the input signal line and the power supply (plus) and short circuits with other input signal lines can be detected. Specifies connecting a safety device with a semiconductor output, such as a light curtain. Not Used Used as Safety Input Used as Standard Input Safety Input Test Source Not used Test Output 0 Test Output 1 Test Output 2 Test Output 3 S Dual Channel Safety Input Mode Single Channel S Specifies connecting a standard device (i. e. , a non-safety device). If the channel mode of a safety input is set to Test Not Used Pulse from Test Out, the test output is selected for use in combination with the safety input. Set the channel mode of the test output selected here to Pulse Test Output. If Single Dual Channel Channel is selected, the safety input that would be Equivalent paired for the dual channel parameter will also be set to Single Channel Mode. Specifies using the Dual Channel Equivalent Mode with a paired safety input. Specifies using Dual Channel Complementary Mode with a paired safety input. Sets the time to monitor the logic discrepancy in the dual channel input logic. Input logic, however, will not be evaluated when this value is set to 0 ms. S Dual Channel Safety Input Discrepancy Time Dual Channel Equivalent Dual Channel Complementary 0 to 65, 530 ms (in increments of 10 ms) 32 characters max. 0 ms --- I/O Comment Sets an I/O comment for the safety input. None The I/O comment set here is used as the I/O tag in the NE1A-series Logic Editor. Sets the operating mode for the maintenance counter. Sets the threshold value for the maintenance counter. [. . . ] The setting can be read for a specified number of points. Write Sets either hold or 10 hex clear as the output status after a communications error for an output (1 to 4) specified by the instance ID. The setting can be read for a specified number of points. 1 byte 00 hex: Clear 01 hex: Hold 09 hex 01 to 04 hex 05 hex 1 byte 00 hex: Clear 01 hex: Hold Note The default setting is for all outputs to be cleared (0). Writing Maintenance Information Explicit message Maintenance Counter Save Read /write Save Function Command Service Class Instance Attribute Data size Code ID ID ID Records the maintenance counter in the Slave's memory 16 hex 95 hex 01 hex Response 113 DeviceNet Explicit Messages Appendix 1 A-1-3 Using Explicit Messages The following example shows how to use explicit messages with the DST1-series Safety I/O Terminals using a CS1W-DRM21 DeviceNet Unit (Master). Example: Reading the Monitor Status for the Operation Time Monitor Example Conditions DeviceNet Unit node address: 05 Unit number: 0 Unit address: FE hex (or 10 hex) DST1 node address: 11 Ladder program DeviceNet Unit CMND C S D Sends explicit message DeviceNet Network DST1 Input 1 Input 2 Discrepancy Error ON Input 1 OFF ON Input 2 OFF Discrepancy time Error Normal Input Flag ON OFF 114 DeviceNet Explicit Messages Command Details · [CMND S D C] S: D01000 D (first response word): D02000 C: D00000 Contents of S Address D01000 D01001 D01002 D01003 D01004 Contents 2801 hex 0B0E hex 003D hex 0001 hex 6E** hex Meaning Command code DST1 node address: 11 Service code: 0E hex Class ID: 003D hex Instance ID: 0001 hex Attribute ID: 6E [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON DEVICENET SAFETY

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON DEVICENET SAFETY will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag