[. . . ] Cables and Connectors
Communi cations Cables
Thin Cables, Connector Type: M icro-size (Standard M 12)
Model number DCA1-5CN DCA1-5CN DCA1-5CN DCA1-5CN DCN2-1 W1 F1 H1 W5 Description Cable with shielded connectors at both ends Cable with shielded connector (female socket) at one end Cable with shielded connector (male plug) at one end Cable with shielded connectors at both ends (Mini-size end: plug (male); Micro-size end: socket (female)) Shielded T-branch connector (one branch line)
Available M odels
Model number DRT2-HD16C DRT2-HD16C-1 DRT2-ID08C DRT2-ID08C-1 DRT2-OD08C DRT2-OD08C-1 16 inputs, NPN 16 inputs, PNP 8 inputs, NPN 8 inputs, PNP 8 outputs, NPN 8 outputs, PNP Specification
Smart Slaves
Achieving remote maintenance with
the smallest environment-resistive slaves in the industry.
24. 3 Two, 5. 3 dia. or M5 mounting holes 26. 6
35 35 35 35 41 41 41 41 2 2 2 2
Thick Cables, Connector Type: M ini-size
DCA2-5CN DCA2-5CN DCA1-5CN DCN3-11 DCN3-12 W1 F1 H1 Cable with shielded connectors at both ends Cable with shielded connector (female socket) at one end Cable with shielded connector (male plug) at one end Shielded T-branch connector (one branch line) Shielded T-branch connector (one branch line) An M12 connector is used for the branch line.
Dimensions (mm)
Environment-resistive Terminals with 8 or 16 Inputs
DRT2-HD16C DRT2-HD16C-1 DRT2-ID08C DRT2-ID08C-1
37. 7 27. 3
A B A B A B A B
60
2
1 2
3 4
5 6
7 8
Connectors with Terminat ing Resistance
DRS2-1 DRS2-2 DRS3-1 Micro-size connector with terminating resistance (male plug) Micro-size connector with terminating resistance (female socket) Mini-size connector with terminating resistance (male plug)
175
Cables for Connected Devices and Internal and I/ O Power Supplies
Cables for Internal and I/ O Power Supplies
Model number XS4W-D421-1 XS4F-D421-1 XS4H-D421-1 XS4R-D424-5 T -A -A -A Description Cable with connectors at both ends (plug and socket) Cable with connector at one end (female socket) Cable with connector at one end (male plug) T-joint
Mounting Hole Dimensions
165±0. 2
Environment-resistive Terminals with 8 Outputs
DRT2-OD08C DRT2-OD08C-1
60
Model number XS2H-D421- 80-A XS2W-D42 - 81-A XS2G-D4
Description Cable with connector at one end (female socket) Cable with connectors at both ends (plug and socket) Connector plug (male) for custom cable assembly (Crimp and solder models available. )
175
43. 9
27. 3
Mounting Hole Dimensions
Two, 5. 3 dia. [. . . ] Conforms to IEC61000-4-4: 2 kV (power lines) 10 to 150 Hz, 0. 7-mm double amplitude 200 m/s
2
Output Specifications
Item Model number Internal I/O common processing Number of I/O points Rated output current I/O power supply voltage Residual voltage Leakage current I/O power supply voltage ON delay time OFF delay time Number of points per common DRT2-OD08C NPN 8 outputs 1. 5 A per point, 8. 0 A per common 20. 4 to 26. 4 VDC (24 VDC 15% to +10%) 1. 2 V max. (1. 5 A DC between each output terminal and G) 1. 2 V max. (1. 5 A DC between each output terminal and V) Specification DRT2-OD08C-1 PNP
500 VAC (between isolated circuits) 20 M min. (between isolated circuits) 10 to 55°C 25% to 85% No corrosive gases 20 to 65°C IP67 Mounting using M5 screws (front and back) 100 N 30 N Round connectors (for communications, power supply, and I/O): 0. 39 to 0. 49 N·m DRT2-HD16C(-1)/ID08C(-1): 340 g DRT2-OD08C(-1): 390 g
Smart Functions
The Terminals provide smart functions that improve remote maintenance. A variety of information can be collected for maintenance systems without influencing control systems and productivity.
Control System M aintenance System
0. 1 mA max. 20. 4 to 26. 4 VDC (24 VDC 15% to +10%) 0. 5 ms max. 8 points per common
List of Functions
Easy-to-view Display
Configurator
: Supported
Model Input
: Not supported
Output
PLC
Maintenance is required for cylinder 23A in inspection line A!
2
Environment-resistive Terminals
Function Contact operation counter Unit conduction time monitor Naming slaves and connected devices Communications power voltage monitor I/O power status monitor Communications error history monitor Input filter Sensor inrush current prevention Sensor power short-circuit protection External load short-circuit protection Sensor disconnection detection
Note: Add the current consumption of the input devices to determine the required power supply capacity.
Input Specifications
Item Model number Internal I/O common processing Number of I/O points ON voltage OFF voltage OFF current Input current Sensor power supply voltage DRT2-ID08C NPN 8 inputs 9 VDC min. (between each input terminal and V) 9 VDC min. (between each input terminal and G) 5 VDC min. (between each input terminal and V) 5 VDC min. (between each input terminal and G) DRT2-ID08C-1 PNP Specification DRT2-HD16C NPN 16 inputs 9 VDC min. (between each input terminal and V) 9 VDC min. [. . . ] Notification of any short-circuits that are detected is provided as part of status information. This enables stable operation.
V Input 9 Input 11 2 3G
2
1
2 1 Input 13 V Input 15 2 3G 4
2 NC 2 NC V1
1
V
2 NC 2
1
V G
2 NC 2 NC V1
1
V
3G
3G
Input 3
1 V 4
NC
3
3
G
Input 2
1 V
4 1 Input 6 V Input 10
1 V
Input 14
Input 1 V
4
1
Input 3
4
4
Input 5
V1
Input 7
1 V
4
Output 1
1 V
4
1
4
Output 3
Output 5
1 V
4
Output 7
Blue Brown (Black) (White) Two-wire sensor (e. g. , limit switch)
35 41 2 2 35 41 2 35 41 2 35 41
Blue Black Brown Blue Black (Black) (White) (Red) (Black) (White) Three-wire sensor with Three-wire sensor with NPN NPN output (e. g. , output (e. g. , photoelectric photoelectric sensor or sensor or proximity sensor) proximity sensor)
CAN L 4 G3 4
Blue Brown (Black) (White) Two-wire sensor (e. g. , limit switch)
Blue Black Brown (Black) (White) (Red) Three-wire sensor with NPN output (e. g. , photoelectric sensor or proximity sensor)
I/O power supply Solenoid valve, etc. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON DRT2-HD16C
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.