[. . . ] Cylindrical Proximity Sensor
E2AG
· Highest value-performance ratio for standard applications · Shielded and unshielded models with standard sensing range
Ordering information
Appearance
M8 Shielded M12 M18 M30 Unshielded M8 M12 M18 M30
Sensing distance
1. 5 mm 2 mm 5 mm 10 mm 2 mm 5 mm 10 mm 18 mm
Output
Type Operation mode NO
E2AG-S08KS01-WP-B1 E2AG-M12KS02-WP-B1 E2AG-M18KS05-WS-B1 E2AG-M30KS10-WS-B1 E2AG-S08KN02-WP-B1
Operation mode NC
E2AG-S08KS01-WP-B2 E2AG-M12KS02-WP-B2 E2AG-M18KS05-WS-B2 E2AG-M30KS10-WS-B2 E2AG-S08KN02-WP-B2 E2AG-M12KN05-WP-B2 E2AG-M18KN10-WS-B2 E2AG-M30KN18-WS-B2
PNP
PNP
E2AG-M12KN05-WP-B1 E2AG-M18KN10-WS-B1 E2AG-M30KN18-WS-B1
Note: Add the cable length to the model number (example: E2AG-M12KS02-WP-B1 2M).
E2AG
1
Model Number Legend
E2AG-Housing shape and material M: Cylindrical, metric threaded, brass S: Cylindrical, metric threaded, stainless steel (only M8) 2. [. . . ] Cable length Numeral: Cable length
eg. , E2AG-M 12 K N 05-WP-B 1-2M Cable length: 2 m NO DC, 3 wire, PNP pre-wired, PVC, dia 4 mm Sensing distance 3 mm Unshielded Standard length M12 Cylindrical, brass
eg. , E2AG-S 08 K S 01-WP-B 1-2M Cable length: 2 m NO DC, 3 wire, PNP pre-wired, PVC, dia 4 mm Sensing distance 1. 5 mm Shielded Standard length M8 Cylindrical, stainless steel
2
Cylindrical Proximity Sensor
Specifications
Item Shielded
E2AGS08KS01-@-B1 E2AGS08KS01-@-B2 Sensing distance Detectable object Standard sensing object Response frequency*1 Power supply voltage (operating voltage range) Current consumption Control output Load current Residual voltage 1. 5 mm ±10%
M8 Unshielded
E2AGS08KN02-@-B1 E2AGS08KN02-@-B2 2 mm ±10%
Shielded
M12 Unshielded
E2AGM12KN05-@-B1 E2AGM12KN05-@-B2 5 mm ±10%
Shielded
M18 Unshielded
E2AGM18KN10-@-B1 E2AGM18KN10-@-B2 10 mm ±10%
Shielded
M30 Unshielded
E2AGM30KN18-@-B1 E2AGM30KN18-@-B2 18 mm ±10%
E2AGM12KS02-@-B1 E2AGM12KS02-@-B2
E2AGM18KS05-@-B1 E2AGM18KS05-@-B2
E2AGM30KS10-@-B1 E2AGM30KS10-@-B2
Differential travel 10% max. of sensing distance Ferrous metal (The sensing distance decrease with non-ferrous metal. Refer to Engineering Data on pages 4 and 5) Iron 8×8×1 mm 1 kHz Iron 12×12×1 mm 0. 4 kHz 0. 8 kHz Iron 15×15×1 mm 0. 1 kHz Iron 18×18×1 mm 0. 5 kHz Iron 30×30×1 mm 0. 1 kHz 0. 1 kHz Iron 54×54×1 mm 0. 1 kHz
12 to 24 VDC. (under load current of 200 mA with cable length of 2 m) Operation indicator (yellow)
Indicator
Operation mode B1 Models: NO B2 Models: NC (with sensing object approaching) Refer to the timing charts under Output Circurt Diagrams of page 7 for details. Protection circuits Ambient temperature range Ambient humidity range Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Weight Materials Case Sensing surface Reverse polarity protection, Surge suppressor, Load short-circurt protection Operating / Storage: -25~+70°C (with no icing or condensation) Operating / Storage: 35~95% RH ±10% max. of sensing distance in rated voltage range ±15% 50 M min. (at 500 VDC) between current carry parts and case 1, 000 VAC, 50/60 Hz for 1 minute between current carry parts and case 10~55 Hz 0. 75 mm double amplitude for 2 hours each in X, Y, and Z directions 500 m/s² 10 times each in X, Y, and Z directions IEC 60529 IP67 Pre-wired models (Standard cable length: 2 m) Approx. 55 g Stainless steel (SUS303) PBT Approx. 190 g 1, 000 m/s² 10 times each in X, Y, and Z directions
*1.
The response frequency is an average value. Measurement conditions are as follows:standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance.
E2AG
3
Engineering data (typical)
Sensing Area
DC 3-wire models/shielded
Distance X (mm)
DC 3-wire models/unshielded
Distance X (mm)
E2AG-M30KS10-@-C/B@ E2G-M30KS10-?-C/B?
E2AG-M30KN18-@-C/B@
E2G-M18KS05 E2AG-M18KS05 -?-C/B?-@-C/B@
E2G-M12KS02 E2AG-M12KS02 -?-C/B?-@-C/B@
E2AG-M18KN10-@-C/B@ E2AG-M12KN05 -@-C/B@ E2AG-S08KN02 -@-C/B@
E2AGE2GS08KS01 -@-C/B@ -?-C/B?
Distance Y (mm)
Distance Y (mm)
Influence of sensing object size and material
DC 3-wire models/shielded
E2AG-S08KS01-@-C/B@
Distance X (mm) Distance X (mm)
E2AG-M12KS02-@-C/B@
Iron Stainless steel
Iron Stainless steel
Brass Brass Aluminum Aluminum
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2AG-M18KS05-@-C/B@
Distance X (mm) Distance X (mm)
E2AG-M30KS10-@-C/B@
Iron
Iron Stainless steel
Stainless steel
Brass Aluminum
Brass Aluminum
Side length of sensing object d (mm)
Side length of sensing object d (mm)
4
Cylindrical Proximity Sensor
DC 3-wire models/unshielded
E2AG-S08KN02-@-C/B@
Distance X (mm) Distance X (mm)
E2AG-M12KN05-@-C/B@
Iron Stainless steel
Iron Stainless steel
Brass Aluminum Copper
Brass Aluminum
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2AG-M18KN10-@-C/B@
Distance X (mm) Distance X (mm)
E2AG-M30KN18-@-C/B@
Iron
Iron Stainless steel
Stainless steel
Brass Aluminum
Brass Aluminum
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2AG
5
Dimensions
Pre-wired models (shielded)
(All units are millimeters unless particular indicated. )
Pre-wired models (unshielded)
Fig. [. . . ] The load short-circuit protection function operates when the power supply is connected with the correct polarity and the power is within the rated voltage range.
E2AG
7
Cat. E61E-EN-01
In the interest of product improvement, specifications are subject to change without notice.
8
Cylindrical Proximity Sensor [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E2AG
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.