[. . . ] of sensing distance at 23°C within temperature range of -40°C to 85°C ±10% max. of sensing distance at 23°C within temperature range of -25°C to70°C ±1% max. of Sensing distance in rated voltage range ±15%. [. . . ] Operation indicator (red), operation setting indicator (green) Operating/Storage: 35% to 95%RH (with no condensation) 50 M min. (at 500 VDC) between energized parts and case 1, 000 VAC for 1 min between energized parts and case 10 to 55 Hz, 1. 5 mm double amplitude for 2 hours each in X, Y, and Z directions IEC60529 IP67 Teflon resin coating (base: brass) * Teflon resin * Instruction manual
* Teflon is a registered trademark of Dupont Company and Mitsui Dupont Chemical Company for their fluoride resin.
E2EQ
D-173
Characteristic data (typical)
Sensing Distance vs. Sensing Object E2EQ-X4X1(-M1J)
Sensing distance X (mm)
5
E2EQ-X8X1(-M1J)
Sensing distance X (mm)
10
E2EQ-X15X1(-M1J)
Sensing distance X (mm)
20
#d
X
#d
X
t=1mm Mild steel
t=1mm Mild steel
#d
X
t=1mm Mild steel
4 Stainless steel (SUS304) 3 Brass 2 Copper 1
8
16
6 Stainless steel (SUS304) 4
12 Stainless steel (SUS304) 8 Brass Aluminum 4 Copper
Brass Copper
2
0
5
10
15
20
25
30
35
0
10
20
30
40
50
0
10
20
30
40
50
60
70
80
Side length of sensing object d (mm)
Side length of sensing object d (mm)
Side length of sensing object d (mm)
E2EQ-X3D1(-M1GJ)
Sensing distance X (mm) 4. 0 3. 5 3. 0 2. 5 2. 0 Aluminum 1. 5 1. 0 0. 5 Brass
E2EQ-X7D1(-M1GJ)
Sensing distance X (mm) 10 9 8 Mild steel 7 6 5 4 Brass 3 Copper 2 1 Aluminum Copper Stainless steel (SUS304)
E2EQ-X10D1(-M1GJ)
Sensing distance X (mm) 14
#d
X
t=1mm
Mild steel Stainless steel (SUS304)
#d
X
t=1mm
#d
12 10 8 6
X
t=1mm
Mild steel
Stainless steel (SUS304)
Brass 4 2 Aluminum Copper
0
5
10
15 20 25 30 35 Side length of sensing object d (mm)
0
5
10
15 20 25 30 35 40 45 Side length of sensing object d (mm)
0
5
10
15
20 25 30 35 40 45 50 55 Side length of sensing object d (mm)
D-174
Inductive Sensors
Output Circuit Diagram
Extended-distance type
Model Operating status Timing chart Output circuit
4
Brown Load
+V
Setting point Non-sensing zone Unstable sensing zone Stable sensing zone
Main circuit
3
E2EQ-X4X1 E2EQ-X8X1 E2EQ-X15X1 E2EQ-X4X1-M1J E2EQ-X8X1-M1J E2EQ-X15X1-M1J
Blue
0V
Sensing object
NO
(%)
100 Rated sensing distance
80(TYP)
0 Lit Not lit Lit Not lit ON OFF Green indicator Red indicator Control output
Note: 1. The load can be connected to either the +V or the 0-V line. Since there is no polarity, there is no need to pay attention to the brown or blue polarity.
Wiring
1 2 3 4
Note: Terminals B and C are not used.
Standard
Model Operating status Timing chart Output circuit
Brown
Setting point Non-sensing zone Unstable sensing zone Stable sensing zone Main circuit
1
Main circuit
Load
+V
E2EQ-X3D1 E2EQ-X7D1 E2EQ-X10D1 E2EQ-X3D1-M1GJ E2EQ-X7D1-M1GJ E2EQ-X10D1-M1GJ
Sensing object (%) 100 80(TYP) 0
4
Blue
0V
NO
Rated sensing distance
Lit Green indicator Not lit Lit Red indicator Not lit ON Control output OFF
Note: The Load can be connected to either the +V or the 0-V line. Wiring A B C Note: Terminals B and C are not used. D
Connecting Plug-in models
Model E2EQ-X#X1-M1J E2EQ-X#D1-M1GJ
Connector relay type E2EQ-X#X1-M1J
Connection
Main circuit
1 2 3 4
Sensor I/O Connectors XS2F-D42#-#C0-A
1 2 3 4
Connector relay type E2EQ-X#D1-M1GJ
Brown not connected Blue (+) Black (-) Main circuit
1 2 3 4
Sensor I/O Connectors XS2F-D42#-#A0-A
1 2 3 4
Brown (+)
Blue (-)
E2EQ
D-175
E2EQ
Precautions
Correct Use
Design Effects of Surrounding Metal Provide a minimum distance between the Sensor and the surrounding metal as shown in the table below. Mounting Do not tighten the nut with excessive force. A washer must be used with the nut.
Shielded Model
l
d dia. m
Model E2EQ-X4X1(-M1J) E2EQ-X8X1(-M1J) E2EQ-X15X1(-M1J) E2EQ-X3D11(-M1GJ) E2EQ-X7D1(-M1GJ) E2EQ-X10D1(-M1GJ) 0 Item l 2. 4 3. 6 6
D
n m
l
Part B Part A
Effects of Surrounding Metal (Unit: mm)
d 18 27 45 12 18 30 0 D 2. 4 3. 6 6 m 12 24 45 8 20 40 n 18 27 45 18 27 45
Note: 1 . The table below shows the tightening torques for part A and part B nuts. In the previous examples, the nut is on the sensor head side (part B) and hence the tightening torque for part B applies. If this nut is in part A, the tightening torque for part A applies instead. The table below shows the value of tightening torques when using toothed washers. Torque Model E2EQ-X4X1(-M1J) E2EQ-X8X1(-M1J) E2EQ-X15A(-M1J) E2EQ-X3D1(-M1GJ) E2EQ-X7D1(-M1GJ) E2EQ-X10D1(-M1GJ) 24 15 Nm --Length (mm) Part A Torque 30 Nm 70 Nm 180 Nm Part B Torque
---
Mutual Interference If more than one Proximity Sensor is installed face to face or in parallel, make sure that the distances between two Units adjacent to each other are the same as or larger than the corresponding values shown in the following table.
29 26 39 Nm 78 Nm
B A
Mutual Interference(Unit: mm)
Model E2EQ-X4X1(-M1J) E2EQ-X8X1(-M1J) E2EQ-X15X1(-M1J) E2EQ-X3D1(-M1GJ) E2EQ-X7D1(-M1GJ) E2EQ-X10D1(-M1GJ) Item A 30 60 110 30 50 100 B 20 35 90 20 35 70
D-176
Inductive Sensors
Dimensions (Unit: mm)
Pre-wired Models Extended-distance type E2EQ-X4X1
38 33 4 10 2 9
21 dia. 17
*1 M12 x 1 Indicator *2 Two, clamping nuts Toothed washer *1: Vinyl-insulated round cable (flame-resistant), 4 dia. [. . . ] 36
42 38 10
M18 x 1
4
*1 Indicator *2 Two, clamping nuts (Teflon coating) Two, toothed washer
M30 x 1. 5 5
*1 Indicator *2 Two, clamping nuts (Teflon coating) Two, toothed washer
*1: Vinyl-insulated round cable (flame-resistant), 6 dia. , 2 conductors (conducting cross-sectional area: 0. 5 mm2/insulator diameter: 1. 9 mm Standard length: 2m Cable extension (through a single metal conduit): 200m max. *2: Operation indicator (red) and setting indicator (green).
*1: Vinyl-insulated round cable (flame-resistant), 6 dia. , 2 conductors (conducting cross-sectional area: 0. 5 mm2/insulator diameter: 1. 9 mm Standard length: 2m Cable extension (through a single metal conduit): 200m max. To convert millimeters into inches, multiply by 0. 03937. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E2EQ
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.