User manual OMRON E2F DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E2F. We hope that this OMRON E2F user guide will be useful to you.

Lastmanuals help download the user guide OMRON E2F.


Mode d'emploi OMRON E2F
Download
Manual abstract: user guide OMRON E2FDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Cylindrical Proximity Sensor in Plastic Housing E2F · High quality full body plastic housing for high water proof requirements · Polyarylate housing for light chemical resistance Applications Detection of bottle caps Warm water cleaning High humidity environment Ordering Information Sensors Model Model Sensing distance Output specifications NO M8 DC 3-wire NPN 1. 5mm Operating status NC E2F-X1R5E2 E2F-X1R5Y2 E2F-X2E2 *1 E2F-X2Y2 *1 E2F-X5E2 *1 E2F-X5Y2 *1 *2 E2F-X10E2 *1 E2F-X10Y2 *1 *2 E2F-X1R5E1 E2F-X1R5Y1 E2F-X2E1 *1 E2F-X2Y1 *1 E2F-X5E1 *1 *1 E2F-X5Y1 *2 E2F-X10E1 *1 *1 E2F-X10Y1 *2 AC 2-wire Models DC 3-wire NPN Shielded M12 2mm AC 2-wire Models M18 5mm DC 3-wire NPN AC 2-wire Models DC 3-wire NPN AC 2-wire Models M30 10mm *1. A different frequency type is available. A short-circuit protection type is available. [. . . ] 170 g Indicator lamp Operating status (with sensing object approaching) Protective circuits Ambient humidity Temperature influence Voltage influence Ambient temperature Operating/Storage: -25° C to 70° C (with no icing or condensation) Insulation resistance 50 M min. (at 500 VDC) between current carry parts and case Dielectric strength Vibration resistance Shock resistance Protective structure Connection method Weight (Packed state) Case Material Sensing surface Clamping nut Accessories Polyallylate resin Instruction manual Polyarylate *1. The response frequencies are average values measured on condition that the distance between each sensing object is twice as large as the size of the sensing object and the sensing distance set is half of the maximum sensing distance. D-30 Inductive Sensors Characteristic data (typical) Sensing Distance vs. Sensing distance X (mm) 2. 5 #d E2F-X2 Sensing distance X (mm) 2. 4 2. 2 2 1. 8 1. 6 1. 4 1. 2 1 0. 8 X 2. 0 t=1mm #d X t=1mm 1. 5 Mild s Stainl (SUS 1. 0 Brass 0. 5 Alum 0. 6 0. 4 0. 2 0 5 10 15 Side length of sensin 0 5 10 15 Side length of sensin E2F-X5 Sensing distance X (mm) 7 6 5 4 #d E2F-X10 Sensing distance X (mm) 12 11 10 9 8 7 6 Stainless steel (SUS304) X t=1mm #d X t=1mm Mild steel 3 2 1 5 4 3 2 1 Brass Aluminum 0 5 10 15 Output Circuit Diagram Output Operating status Model Timing chart Sensing object Yes No Brown 100W Load 4. 7kW Main circuit 2. 2W *1 Black Output *2 Blue Tr +V Output circuit NO E2F-X1R5E1 E2F-X2E1 E2F-X5E1 E2F-X10E1 Load (between brown Operates and black leads) Reset Output voltage (between black and blue leads) Detection indicator H L ON OFF Yes No DC 3wire E2F-X1R5E2 E2F-X2E2 E2F-X5E2 E2F-X10E2 Sensing object NC Load (between brown Operates and black leads) Reset Output voltage (between black and blue leads) Detection indicator H L ON OFF Yes No Operates Reset ON OFF 0V *1. When connecting to the transistor circuit. NO AC 2wire Models NC E2F-X1R5Y1 E2F-X2Y1 E2F-X5Y1 E2F-X10Y1 Sensing object Load Detection indicator Brown Load Main circuit Blue E2F-X1R5Y2 E2F-X2Y2 E2F-X5Y2 E2F-X10Y2 Sensing object Load Detection indicator Yes No Operates Reset ON OFF E2F D-31 E2F 20 25 30 3 Side length of sensi 0 10 20 30 40 50 60 Side length of sensing object d (mm) Precautions Correct Use Design Effects of Surrounding Metal Provide a minimum distance as shown in the table below between the Sensor and the surrounding metal. l Mounting Do not apply excessive torque when tightening any nuts. Model E2F-X1R5 Tensile strength (torque) 0. 78 N·m 2 N·m d dia. m Effects of Surrounding Metal(Unit: mm) Model E2F-X1R5 18 30 Item l d 8 12 0 20 40 D m 4. 5 8 D n m l Maintenance and Inspection Do not use the AC 2-wire models (sensing surface is broken), where directly exposed to water. There is fear of an electric shock. n 12 18 27 45 Mutual Interference When installing two or more Sensors face-to-face or side-byside, ensure that the minimum distances given in the following table are maintained. A Mutual Interference (Unit: mm) Model E2F-X1R5 Item A 20 30 (20) 50 (30) 100(50) B B 15 20(12) 35 (18) 70(35) Note: Figures in parentheses are for an E2F used in combination with an E2F (i. e. , E2F-X@5) that is operating at a different frequency. D-32 Inductive Sensors Dimensions (Unit: mm) DC 3-wire Models E2F-X1R5E@ AC 2-wire Models E2F-X1R5Y@ 15 dia. 13 40 32 29 (see note) M8 x 1 4 Indicator Two, clamping nuts Two, washers M8 x 1 4 Indicator Two, clamping nuts Two, washers (see note) Note: Vinyl-insulated round cord, 3. 5 dia. , 3 cores (0. 12 dia. x 13); Standard length: 2m Note: Vinyl-insulated round cord, 3. 5 dia. , 3 cores (0. 12 dia. [. . . ] To convert millimeters into inches, multiply by 0. 03937. To convert grams into ounces, multiply by 0. 03527. D07E-EN-01 In the interest of product improvement, specifications are subject to change without notice. D-34 Inductive Sensors [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E2F

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E2F will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag