User manual OMRON E2FM DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E2FM. We hope that this OMRON E2FM user guide will be useful to you.

Lastmanuals help download the user guide OMRON E2FM.


Mode d'emploi OMRON E2FM
Download
Manual abstract: user guide OMRON E2FMDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. E2FM A-3 DC 3-Wire (E2FM-X@B@) Size Shielded Item Set distance Differential travel Sensing object Standard sensing object Power supply voltage (operating voltage range) Current consumption Output configuration Control output Indicators Operation mode (with sensing object approaching) Protection circuits Ambient temperature range Ambient humidity range Temperature influence Voltage influence Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Case Sensing surface Materials (thickness) Clamping nuts Toothed washer Accessories Switching capacity Residual voltage Model E2FM-X1R5B1-M1 1. 5 mm±10% 0 to 1. 05 mm E2FM-X2B1-M1 2 mm±10% 0 to 1. 4 mm Sensing distance M8 M12 Shielded E2FM-X5B1-M1 5 mm±10% 0 to 3. 5 mm E2FM-X10B1-M1 10 mm±10% 0 to 7 mm M18 M30 15% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page 5. ) Iron, 8 × 8 × 1 mm Iron, 12 × 12 × 1 mm 100 Hz Iron, 30 × 30 × 1 mm 100 Hz Iron, 54 × 54 × 1 mm 50 Hz Response frequency * 200 Hz 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. (Load current: 200 mA, Cable length: 2 m) Operation indicator (yellow LED) NO Reversed power supply polarity protection, Surge suppressor, Load short-circuit protection, and Reversed output polarity protection (except the E2FM-X1R5B1-M1) Operating/Storage: -25 to 70° C (with no icing or condensation) Operating/Storage: 35% to 95% (with no condensation) ±20% max. [. . . ] Applying a voltage that is higher than the operating voltage range may result in explosion or fire. Incorrect Wiring Be sure that the power supply polarity and other wiring is correct. Incorrect wiring may cause explosion or fire. Connection without a Load If the power supply is connected directly without a load, the internal elements may explode or burn. Be sure to insert a load when connecting the power supply. Mutual Interference When installing two or more Sensors face-to-face or side-byside, ensure that the minimum distances given in the following table are maintained. (Unit: mm) Model E2FM-X2@ E2FM-X5@ Item A 35 40 65 110 B 30 35 60 100 E2FM-X1R5@ A B E2FM-X10@ Precautions for Correct Use Do not use the Sensor under ambient conditions that exceed the ratings to ensure maximum lifetime: 1. Please do not use the Sensor in the following locations. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) *1. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) E2FM-X5D1-M1GJ E2FM-X5D1-M1GJ-T 56 42 36 29 dia. E2FM-X10D1-M1GJ E2FM-X10D1-M1GJ-T 63. 5 49 43 42 dia. 5 10 4 10 M12 × 1 M12 × 1 24 M18 × 1 Two clamping nuts Toothed washer Indicator *2 *1 36 M30 × 1. 5 *1. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) Two clamping nuts Toothed washer *1 Indicator *2 *1. vinyl-insulated round cable (flame retardant), Standard length; 300 mm *2. Operation indicator (red/green) Setting indicator (green) M12 Connector Models E2FM-X1R5B1-M1 53. 5 34. 5 30 25 15 dia. 21 dia. E2FM-X2B1-M1 53 39 33 4 7 4 5 13 M8 × 1 Toothed washer Two clamping M12 × 1 nuts Four operation indicators (yellow) 17 M12 × 1 Two clamping nuts M12 × 1 Four operation indicators (yellow) Toothed washer E2FM-X5B1-M1 E2FM-X10B1-M1 63. 5 49 56 42 36 4 10 42 dia. 43 5 10 29 dia. M12 × 1 24 M18 × 1 Two clamping nuts Toothed washer Four operation indicators (yellow) M12 × 1 36 M30 × 1. 5 Two clamping nuts Four operation indicators (yellow) Toothed washer Mounting Hole Dimensions Dimension F (mm) F M8 8. 5 +0. 5 dia. 0 A-8 Inductive Proximity Sensor READ AND UNDERSTAND THIS DOCUMENT Please read and understand this document before using the products. Please consult your OMRON representative if you have any questions or comments. PERFORMANCE DATA Performance data given in this document is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. E2FM WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. [. . . ] At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this document. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E2FM

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E2FM will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag