User manual OMRON E2Q5 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E2Q5. We hope that this OMRON E2Q5 user guide will be useful to you.

Lastmanuals help download the user guide OMRON E2Q5.


Mode d'emploi OMRON E2Q5
Download
Manual abstract: user guide OMRON E2Q5DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Long Distance Square Inductive Proximity Sensor E2Q5 Square Proximity Sensor · M12 Plug-in connection · Integrated short circuit and reverse polarity protection · Active face positioning: Y-axis 15°, X-axis 90° incremets Ordering Information Sensing distance 20 mm shielded 40 mm non-shielded Connection Active face NPN PNP NPN PNP Output NO E2Q5-N20E1-M1 E2Q5-N20F1-M1 E2Q5-N40ME1-M1 E2Q5-N40MF1-M1 NO + NC E2Q5-N20E3- M1 E2Q5-N20F3- M1 E2Q5-N40ME3- M1 E2Q5-N40MF3- M1 E2Q5 Plug-in connector Changable E2Q5 D-1 Rating/performance shielded non-shielded E2Q5-N20 ## -M1 E2Q5-N40M # 3- M1 20 mm ± 10% 40 mm ± 10% 60 x 60 x 1 mm 120 x 120 x 1 mm 0 to 16, 2 mm 0 to 32, 4 mm 150 Hz Ferrous metals 15% max. of sensing distance Sn 10 to 30 VDC 20 mA max. [. . . ] If the load and Sensor are connected to independent power supplies respectively, be sure to turn ON the Sensor before supplying power to the load. Power OFF The Proximity Sensor may output a pulse signal when it is turned OFF. Therefore, it is recommended that the load be turned OFF before turning OFF the Proximity Sensor. Power Supply Transformer When using a DC power supply, make sure that the DC power supply has an insulated transformer. Do not use a DC power supply with an auto-transformer. Sensing Object The sensing distance of the Proximity Sensor vary with the metal coating on sensing objects. Wiring Power Supply Voltage and Output Load Power Supply Voltage Make sure that the power supply to the Sensor is within the rated voltage range. If a voltage exceeding the rated voltage range is supplied to the Sensor, it may explode or burn. Load Short-circuiting Do not short-circuit the load, otherwise the Sensor may be damaged. Connection without Load Do not connect the power supply to the Sensor with no load connected, otherwise the internal elements may explode or burn. E2Q5 Wiring Operating Environment Do not use the Sensor in locations with explosive or flammable gas. High-tension cables Wiring through Metal Conduit: If there is power or high-tension line near the cable of the Proximity Sensor, wire the cable through an independent metal conduit to prevent against Proximity Sensor damage or malfunction. Correct Use Design Effects of Surrounding Metal Provide a minimum distance between the Sensor and the surrounding metal as shown in the table below. B A C Effects of Surrounding Metal (Unit: mm) Model E2Q5-N20 # #-M1 E2Q5-N40M # #-M1 Length A 45 120 B 0 300 C 0 40 E2Q5 D-5 Mounting Mounting the Sensor The Proximity Sensor must be subjected to excessive shock with a hammer when it is installed, otherwise the Proximity Sensor may be damaged or lose its water-resistivity. Environment Water Resistivity Do not use the Proximity Sensor underwater, outdoors or in the rain. Operating Environment Be sure to use the Proximity Sensor within its operating ambient temperature range and do not use the Proximity Sensor outdoors so that its reliability and life expectancy can be maintained. Although the Proximity Sensor is water resistive, a cover to protect the Proximity Sensor from water or water-soluble machining oil is recommended so that its reliability and life expectancy can be maintained. Do not use the Proximity Sensor in an environment with chemical gas (e. g. , strong alkaline or acid gasses including nitric, chromic and concentrated sulfuric acid gases). Inrush Current A load that has a large inrush current (e. g. , a lamp or motor) will damage the Proximity Snesor, in this case connect the load to the Proximity Sensor through a Relay Maintenance and Inspection Periodically perform the following checks to ensure stable operation of the Proximity Sensor over a long period of time. [. . . ] To convert grams into ounces, multiply by 0. 03527. E47E-EN-01 In the interest of product improvement, specifications are subject to change without notice. D-6 Inductive Sensors [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E2Q5

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E2Q5 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag