User manual OMRON E3C-LDA DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3C-LDA. We hope that this OMRON E3C-LDA user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3C-LDA.


Mode d'emploi OMRON E3C-LDA
Download

You may also download the following manuals related to this product:

   OMRON E3C-LDA DATASHEET 3 (764 ko)
   OMRON E3C-LDA DATASHEET 2 (572 ko)

Manual abstract: user guide OMRON E3C-LDADATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Optimize for workpieces and improve inspection quality. · Drive the laser with an Amplifier the same size as a Digital Fiber Amplifier. Ordering Information Sensor Heads Sensing method Diffuse reflective Spot Line Area Coaxial retroreflective Spot (variable) (with MSR) Focus Model number E3C-LD11 E3C-LD21 E3C-LD31 Remarks Mounting a Beam Unit (sold separately) allows the use of line and area beams. This model number is for the set consisting of the E39-P11 mounted to the E3C-LD11. [. . . ] 150 mm) (at distances up to 1, 000 mm) Variable focal point mechanism (beam size adjustment) (See note 4. ), optical axis adjustment mechanism (axis adjustment) LDON indicator: Green; Operation indicator: Orange 3, 000 lx (incandescent lamp) Operating: -10°C to 55°C; Storage: -25°C to 70°C (with no icing or condensation) Operating/storage: 35% to 85% (with no condensation) 10 to 150 Hz with double amplitude of 0. 7 mm, in X, Y, and Z directions for 80 min each IEC 60529: IP40 Case and cover: Front surface filter: Approx. 85 g ABS Acrylic resin Case and cover: ABS Front surface filter: Glass Approx. These values apply when a E39-R12 Reflector is used. The reflected light from the object being measured may affect the sensing accuracy, so adjust the threshold value before use. The beam radius is the value for the middle measurement distance and indicates a typical value for the middle sensing distance. The radius is defined by light intensity of 1/e2 (13. 5%) of the central light intensity. Light will extend beyond the main beam and may be affected by conditions surrounding the object being measured. The E3C-LR12 has a fixed beam size (the focus point cannot be changed). 2 E3C-LDA Series Photoelectric Sensors with Separate Digital Amplifiers (Laser-type Amplifier Units) Amplifier Units Type External-input models E3C-LDA7 E3C-LDA9 Twin-output models E3C-LDA11 E3C-LDA41 E3C-LDA6 E3C-LDA8 ATC-output models E3CLDA11AT E3CLDA41AT E3C-LDA6AT E3C-LDA8AT Analog-output models E3C-LDA11AN E3C-LDA41AN Model NPN output E3C-LDA21 Item Supply voltage Power consumption ConON/OFF output trol output Analog output PNP output E3C-LDA51 12 to 24 VDC ±10%, ripple (p-p) 10% max. at power supply voltage of 24 VDC) Load power supply voltage: 26. 4 VDC max. ; NPN/PNP (depends on model) open collector Load current: 50 mA max. ; residual voltage: 1 V max. --Control output Voltage output: 1 to 5 VDC (connected load 10 k min. ) Temperature characteristics 0. 3% F. S. /°C Response time/Repeat accuracy Super-high-speed mode: 100 µs/ 4. 0% F. S. 100 µs for operation and reset ReSuper-high-speed sponse mode time High-speed mode Standard mode High-resolution mode Functions Differential detection Timer function 80 µs for operation and reset 1 ms for operation and reset 4 ms for operation and reset 250 µs for operation and reset Switchable between single edge and double edge detection mode. Single edge: Can be set to 250 µs, 500 µs, 1 ms, 10 ms, or 100 ms. Double edge: Can be set to 500 µs, 1 ms, 2 ms, 20 ms, or 200 ms. Select from OFF-delay, ON-delay, or one-shot timer. 1 ms to 5 s (1 to 20 ms set in 1-ms increments, 20 to 200 ms set in 10-ms increments, 200 ms to 1 s set in 100-ms increments, and 1 to 5 s set in 1-s increments) Negative values can be displayed. Settings can be returned to defaults as required. [. . . ] × 2 conductors und (cross-sectional area of conductor: 0. 15 mm2) Standard length: 2 m Reflector E39-R12/-R14 30 12 Amplifier Unit E39-R13 E3C-LDA11 76 10 45 37 24 17. 2 32 This document provides information mainly for selecting suitable models. Please read the Instruction Sheet carefully for information that the user must understand and accept before purchase, including information on warranty, limitations of liability, and precautions. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. To convert grams into ounces, multiply by 0. 03527. Cat. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3C-LDA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3C-LDA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag