User manual OMRON E3F2-Z DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3F2-Z. We hope that this OMRON E3F2-Z user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3F2-Z.


Mode d'emploi OMRON E3F2-Z
Download
Manual abstract: user guide OMRON E3F2-ZDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Cylindrical M18 photoelectric sensor for AC power supply E3F2-@Z · 24 to 240 VAC power supply · UL and CSA approved Selection Guide Housing material: Plastic Sensing method Throughbeam Retroreflective Non-polarizing (without MSR function) Appearance Connection method axial pre-wired Sensing distance 3m 0. 1 - 2 m (with reflector E39-R1) 0. 1 m Model Light-ON E3F2-3Z1 Dark-ON E3F2-3Z2 pre-wired axial pre-wired axial E3F2-R2Z1-E E3F2-R2Z2-E Diffuse reflective Fixed sensing distance Wide-beam characteristics E3F2-DS10Z1-N E3F2-DS10Z2-N Note: Standard cable length is 2 m. Models provided with a 5 m long cable are available. When ordering, specify the cable length by adding the length of the cable (e. g. [. . . ] Operating: -25 to 55 °C / Storage: -30 to 70 °C (with no icing or condensation) Operating: 35% to 85% / Storage: 35% to 95% (without condensation) 20 M min. at 500 V DC between energized parts and case 1500 VAC, 50 / 60 Hz for 1 min between energized parts and case 10 to 55 Hz, 1. 5 mm double amplitude for 2 hrs each direction (X, Y, Z) 500 m/sqr (approx. 50 g) for each direction (X, Y, Z) IP67 *4; NEMA 1, 2, 4; IP69k after DIN 40050 part 9 Infrared LED (880 nm) Light incident/power indicator for light source (red) Fixed 2 m, 5 m pre-wired cable (PVC dia. 4 mm (14 / 0. 15) *5) Light-ON or Dark-ON (fixed) None 110 g (pre-wired 2 m cable) Plastic (case: ABS; lens: PMMA) For stable sensing distance in detail, please refer to "Engineering Data" Typical sensing distance corresponds to 80 % of the max. The enclosure rating IP67 of OMRON internal standards correspond to stricter test requirements than the standard IEC 60529 (refer to chapter "Precautions") For other cable materials (e. g. PUR) please contact your OMRON sales representative. 2 Standard Photoelectric Sensors Engineering Data (Typical) Operating Range (typical) Through-beam Models (axial) E3F2-3Z# 300 typical sensing distance: 3. 8 m Retroreflective Models (axial) E3F2-R2Z# (non polarizing) and reflectors 300 typical sensing distances: E39-R1: 3. 4 m E39-R7: 3. 9 m E39-R8: 5. 2 m Diffuse reflective Models (axial) E3F2-DS10Z-# (wide-beam type) 30 200 200 20 Distance Y (mm) Distance Y (mm) 100 100 Distance Y (mm) 10 0 0 0 white paper (50 x 50 mm) ­100 ­100 ­10 ­200 Y ­300 0 1 2 3 X 4 5 ­200 Y ­300 0 1 2 3 4 5 6 X 7 8 Reflector ­20 Y X ­30 0 20 40 60 80 100 120 140 Object Distance X (m) Distance X (m) Distance X (mm) Excess Gain Ratio vs. Distance (typical) Through-beam Models (axial) E3F2-3Z# 100 Retroreflective Models (axial) E3F2-R2Z# (non polarizing) and reflectors 100 Diffuse reflective Models (axial) E3F2-DS10Z-# (wide-beam type) 100 Sensing object: 50 x 50 mm Excess gain Excess gain Excess gain 10 10 10 reflector E39-R1 White paper (90% reflectivity) 1 Grey paper (18% reflectivity) 1 1 reflector E39-R7 reflector E39-R8 0. 1 0 1 2 3 4 5 6 7 0. 1 0 1 2 3 4 5 6 7 0. 1 0 50 100 150 200 Distance X (m) Distance X (m) Distance X (mm) Operation Model Output transistor status Timing chart Connection method Output circuit Through-beam emitter Brown Power indicator (red) E3F2-3LZ ­ ­ ­ Main circuit 24 to 240 VAC Blue Incident Interrupted E3F2-3Z1 E3F2-R2Z1 E3F2-DS10Z1-N ON when light is incident. (Light-ON) Output indicator (red) Output transistor Load (relay) ON OFF ON OFF Operate Release ­ Light indicator Red Main circuit Brown 200 mA max. Black 24 to 240 VAC Blue Load Incident Interrupted E3F2-3Z2 E3F2-R2Z2 E3F2-DS10Z2-N ON when light is interrupted. (DarkON) Output indicator (red) Output transistor Load (relay) ON OFF ON OFF Operate Release ­ E3F2-@Z 3 Dimensions Cable type Without potentiometer E3F2-3Z# E3F2-R2Z# E3F2-DS10Z#-N 8 90 67. 3 62 M18 x 1 6g 24 5 dia. 3. 1 Light indicator 16. 8 dia. 22 3. 1 optical zone Precautions The E3F2 Photoelectric Sensor is not a safety component for ensuring the safety of people which is defined in EC directive (91/368/ EEC) and covered by separate European standards or by any other regulations or standards. When using the photoelectric sensor in the vicinity of an inverter motor, ensure to connect the protective earth ground wire of the motor to earth. Failure to ground the motor may result in malfunction of the sensor. When you use the photoelectric sensor at temperatures exceeding 45 °C, the load current must be within the described values as shown in the figure below. 200 Degree of protection The E3F2 photoelectric sensors have a degree of protection rated with IP67. [. . . ] Do not connect the black wire to the brown wire without a load. Direct connection of these wires may damage the photoelectric sensor (AC switching type). Brown Operating temperature (°C) Installation Do not exceed a torque of · 2. 0 Nm ( 20 kgf cm) when tightening mounting nuts for plastic models · 20. 0 Nm (200 kgf cm) when tightening mounting nuts for metal models Load Sensor Black 24 to 240 VAC Blue Cat. E43E-EN-01 In the interest of product improvement, specifications are subject to change without notice. OMRON EUROPE B. V. Wegalaan 67-69, NL-2132 JD, Hoofddorp, The Netherlands Phone: +31 23 568 13 00 Fax: +31 23 568 13 88 www. eu. omron. com E3F2-@Z 4 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3F2-Z

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3F2-Z will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag