User manual OMRON E3FR DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3FR. We hope that this OMRON E3FR user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3FR.


Mode d'emploi OMRON E3FR
Download
Manual abstract: user guide OMRON E3FRDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Adjuster Blank: with volume adjuster/L-on/D-on by wire H: without volume adjuster/L-on/D-on by wire 7. Emitter/ Receiver L: emitter D: receiver 8. Kind of connection Blank: standard 2 m cable or M12 connector M1J: pre-wired with 30 cm cable and M12 plug connector (4 pin) M3J: pre-wired with 30 cm cable and M8 plug connector (4 pin) M5J: pre-wired with 30 cm cable and M8 plug connector (3 pin) M1TJ: pre-wired with 30cm cable and Twist&Click M12 plug connector (4 pin) 9. Cable length Blank: M12 connector Number: cable length 4 Standard Photoelectric Sensors Mounting and dismounting Mounting Step 1 2. 5 to 2. 9 mm dia 20. 1 to 20. 2 mm Insert the snap holder into the mounting hole from the front Verify the correct position (a clicking sound can be heard) Step 2 Insert the sensor into the snap holder from the back Verify the correct position (a clicking sound can be heard) Dismounting Step 1 Apply soft pressure to the sensor lens in the indicated areas (e. g. [. . . ] Do not use it for such a purpose. Precautions for Correct Use Do not use the Sensor in any atmosphere or environment that exceeds the ratings. Do not install the Sensor in the following locations. (1) Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity (3) Locations subject to corrosive gas (4) Locations where the Sensor may receive direct vibration or shock !Caution Do not use the product with voltage in excess of the rated voltage. Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explostion may result. Connecting and Mounting (1) The maximum power supply voltage is 30 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. (3) Use an extension cable with a minimum thickness of 0. 3 mm2 and less than 100 m long. (4) Do not pull on the cable with excessive force. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. (6) Mount the Sensor either using the bracket (sold separately) or on a flat surface. (7) Be sure to turn OFF the power supply before inserting or removing the connector. When cleaning the product, do not apply a high-pressure spray of water to one part of the product. Otherwise, parts may become damaged and the degree of protection may be degraded. High-temperature environments may result in burn injury. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Sensor. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. Operating Environment Do not use the Sensor in an environment where explosive or flammable gas is present. Power Supply If a commercial switching regulator is used, ground the FG (frame ground) terminal. Connecting Connectors Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0. 39 to 0. 49 N·m for M12 connectors. Power Supply Reset Time The Sensor will be able to detect objects 100 ms after the power supply is tuned ON. Start using the Sensor 100 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. Turning OFF the Power Supply Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line. Load Do not use a load that exceeds the rated load. Rotation Torque for Sensitivity Adjustment Adjust with a torque of 0. 05 N·m or less. Load Short-circuit Protection This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. [. . . ] CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3FR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3FR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag