[. . . ] Detection of large corrugated cardboard Just by installing the sensor on one side, only the boxes to be detected shall be sensed. Detection of cars in multi-story parking lot
10m
E3G-L73 E3G-R13
E3G-R13 E3G-L73
A-120
Standard Photoelectric Sensors
Ordering Information
Sensors
Sensor type Shape Connection method Pre-wired Connector type Sensing distance Timer function
Red light Infrared light
Retroreflective Models (with M. S. R. Function)
---
10m
Terminal block Pre-wired Connector type
[500mm]*
Model NPN/PNP selector Relay contact output E3G-R13-G --E3G-R17-G E3G-MR19-G --E3G-L73 E3G-L77 --E3G-MR19T-G --E3G-ML79-G
ON or OFF delay 0 to 5 s (adjustable) ---
Distancesetting
White paper 300 ¥ 300 mm
Terminal block
0. 2 to 2 m
ON or OFF delay 0 to 5 s (adjustable)
E3G-ML79T-G
* Values in parentheses indicate the minimum required distance between the sensor and reflector.
Accessories (Order Separately)
Reflectors
Shape Sensing distance (typical) 10 m (500 mm) * 6 m (100 mm) * Model E39-R2 E39-R1S Quantity 1 1 Remarks -----
* Values in parentheses indicate the minimum required distance between the sensor and reflector.
Terminal Protection Cover for Side-pullout Cable
Shape Model Quantity Applicable type Remarks
E39-L129-G
1
E3G-MR19(T)-G Provided with rubber bushing and cap for E3G-ML79(T)-G pullout prevention in horizontal direction
Mounting Brackets
Shape Model E39-L131 E39-L132 E39-L135 E39-L136 Quantity 1 E3G-R1# E3G-L7# 1 1 E3G-MR19(T)-G E3G-ML79(T)-G 1 --Rear-mounting use Cable pulled out downwards Applicable type Remarks ---
Sensor I/O Connectors
Cable Shape Cable length 2m 5m 3-wire type Model XS2F-D421-DC0-A XS2F-D421-GC0-A XS2F-D422-DC0-A XS2F-D422-GC0-A
Straight
Standard cable
L-shaped
2m 5m
E3G
A-121
E3G
Rating/Performance
Sensor type Item Model Sensing distance Setting distance Standard sensing object Hysteresis (typical) Directional angle Reflectivity characteristics (black/white error) Light source (wave length) Spot size Power supply voltage Current/Power consumption Retroreflective Models (M. S. R. function) Distance-setting E3G-R13-G E3G-R17-G E3G-MR19-G E3G-MR19T-G E3G-L73 E3G-L77 E3G-ML79-G E3G-ML79T-G 10 m (500 mm) * (When using the E39-R2) 0. 2 to 2 m (White paper 300 x 300 mm) --0. 5 to 1. 2 m (White paper 300 x 300 mm) Opaque: 80 dia. [. . . ] Press the TEACH button with the background. The teaching indicator (red) will turn ON. (Set to L-ON or D-ON mode. )
TEACH
Procedure
Operation Move the sensing object and press the TEACH button with the background. If the teaching is successful, the teaching indicator (green) will turn ON. If the teaching is not successful, the teaching indicator (red) will flash. When the teaching is successful, the setting is complete. (Use the operation mode selector to set L-ON/D-ON. ) When the teaching is not successful, change the work position and setting distance again, and restart the setting from step "3".
4
Note: Perform normal one-point teaching with the background.
5
Normal two-point teaching
Procedure 1 2 3 Operation Set the mode selector to TEACH . Set the NORMAL/ZONE mode selector to NORMAL . Press the TEACH button with a sensing object. The teaching indicator (red) will turn ON.
E3G
A-127
Zone teaching
Procedure 1 2 3 4 Operation Set the mode selector to TEACH . Set the NORMAL/ZONE mode selector to ZONE . Press the TEACH button with the background. The teaching indicator (red) will turn ON and the teaching indicator (green) will then turn ON. (Set to L-ON or D-ON mode. )
Maximum distance setting (in normal mode) If you want to set the maximum distance of the sensor, set a maximum distance as depicted in the following procedure.
Procedure 1 2 3 Operation Set the mode selector to TEACH . Set the NORMAL/ZONE mode selector to NORMAL . The teaching indicator (red) will turn ON. In 3 s, the teaching indicator (green) will turn ON. When the teaching indicator (green) turns ON, the setting is complete. (Set to L-ON/ D-ON. )
Note: Perform zone teaching with the background.
4
Precautions
Correct Use
E3G-R/MR Design Power Supply A full-wave rectification power supply can be used with the E3G-MR19(T)-G. Wiring Considerations The tensile strength of the cable during operation should not exceed the values shown below.
Model E3G-R13-G E3G-MR19(T)-G E3G-R17-G Tensile strength 50 N max. 10 N max.
E3G-L/ML Design Power Supply A full-wave rectification power supply can be used with the E3G-ML79(T)-G. Wiring Considerations The tensile strength of the cable during operation should not exceed the values shown below.
Model E3G-L73 E3G-ML79(T)-G E3G-L77 Tensile strength 50 N max. [. . . ] lens 18 68. 5 67. 8 30 29 12. 8 Emitter 13. 7 21 43 Vinyl-insulated round cable with three conductors, 6 dia. (17 x 0. 16 dia. ); standard length: 2 m 37 43 8 8 7 10 M12 connector 10. 5 dia. 25 25
Terminal block E3G-ML79-G E3G-ML79T-G
Operation indicator Operation mode Indicators M2. 6 (Orange) selector Stability indicator (Green) Teaching indicator (Red and green)
TEACH button
OFF-delay adjuster * ON-delay adjuster * M2. 6 nut Two, 4. 5 dia. mounting holes
E3G-ML79-G does not equipped ON-delay adjuster and OFF-delay adjuster.
Mounting Holes
2-M4
14 Receiver
14 dia. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3G
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.