User manual OMRON E3H2 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3H2. We hope that this OMRON E3H2 user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3H2.


Mode d'emploi OMRON E3H2
Download
Manual abstract: user guide OMRON E3H2DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] a) E3H2-T4 Receiver Default setting (wire left open):DARK-ON Connected to plus (+): LIGHT-ON Connected to common (-): DARK-ON b) E3H2-R2 Default setting (wire left open):DARK-ON Connected to plus (+): LIGHT-ON Connected to common (-): TEACH*1 c) E3H2-DS30 Default setting (wire left open):LIGHT-ON Connected to plus (+): DARK-ON Connected to common (-): TEACH*1 d) E3H2-DS10 Default setting (wire left open):LIGHT-ON Connected to plus (+): DARK-ON Connected to common (-): LIGHT-ON For E3H2-T2 the operation mode is fixed and models with lighton and dark-on operation are available. *1 In case the remote teach operation is required when the white wire is connected to plus (+), add a 2. 2 k resistor between the white wire and (+) to avoid a short circuit. E3H2-R2 a) standard mode To teach the retro-reflective model E3H2-R, place the sensor with the lens facing the reflector. For remote teach connect the white wire (Pin 2) for 2-5 seconds to common (-). The threshold is now set to 50% of the received light level. for semi-transparent models) To teach the retro-reflective model E3H2-R in high sensitivity mode, place the sensor with the lens facing the reflector. [. . . ] fixed for E3H2-T2B2@ 100 mA max. 3 Load (Relay) 0V Blue Connector Pin Arrangement 4 1 3 Through-beam emitter Power indicator (yellow) Photoelectric Sensor Main Circuit 3 Brown 1 Connector Pin Arrangement 10 to 30 VDC Blue 4 1 3 E3H2 7 NPN Output Model E3H2-T4C@ E3H2-R2C@ E3H2-D@C@ Operation Timing charts mode Light ON Light Incident Light Interrupted Operation indicator ON (yellow) OFF ON Output transistor Load (e. g. relay) OFF Operate Reset Mode selector switch For throughbeam and retroreflective: connect the white wire (Pin 2) to the brown wire (Pin 1). For diffuse-reflective: open (do not connect) the white wire (Pin 2). For throughbeam and retroreflective: open (do not connect) the white wire (Pin 2). For diffuse-reflective: connect the white wire (Pin 2) to the brown wire (Pin 1) Through-beam emitter Power indicator (yellow) Photoelectric Sensor Main Circuit 3 Output circuit Through-beam receiver, retro-reflective, diffuse-reflective Operation indicator (Yellow) Photoelectric Sensor Main Circuit Brown 1 10 to 30 VDC Load (Relay) (Control output) 4 100 mA max. Black Blue ZD 3 Dark ON 0V Mode Selection / Teach 2 White Light Incident Light Interrupted Operation indicator ON (yellow) OFF ON Output transistor Load (e. g. relay) OFF Operate Reset Connector Pin Arrangement 1 2 3 4 Brown 1 Connector Pin Arrangement 1 2 3 4 10 to 30 VDC Blue E3H2-T2C@ Light ON Light Incident Light Interrupted Operation indicator ON (yellow) OFF ON Output transistor OFF Load (e. g. - fixed for E3H2-T2C1@ Through-beam receiver Operation indicator (Yellow) Photoelectric Sensor Main Circuit Brown 1 10 to 30 VDC Load (Relay) (Control output) 4 100 mA max. Black Blue Dark ON Light Incident Light Interrupted Operation indicator ON (yellow) OFF Output transistor Load (e. g. Otherwise, parts may become damaged and the degree of protection may be degraded. High-temperature environments may result in burn injury. Precautions for Safe Use The following precautions must be observed to ensure safe operation of the Sensor. Cleaning Never use thinner or other solvents. Otherwise, the Sensor surface may be dissolved. Operating Environment Do not use the Sensor in an environment where explosive or flammable gas is present. Power Supply If a commercial switching regulator is used, ground the FG (frame ground) terminal. Connecting Connectors Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0. 4 to 0. 5 N·m for M12 connectors and 0. 3 Nm for M8 connectors. Power Supply Reset Time The Sensor will be able to detect objects 150 ms after the power supply is tuned ON. Start using the Sensor 150 ms or more after turning ON the power supply. If the load and the Sensor are connected to separate power supplies, be sure to turn ON the Sensor first. Turning OFF the Power Supply Output pulses may be generated even when the power supply is OFF. Therefore, it is recommended to first turn OFF the power supply for the load or the load line. Load Do not use a load that exceeds the rated load. Environements with Cleaners and Disinfectants Do not use the Sensor in environments subject to cleaners and disifectants. They may reduce the degree of protection. Load Short-circuit Protection This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. Modifications Do not attempt to disassemble, repair, or modify the Sensor. Water Resistance Do not use the Sensor in water, rainfall, or outdoors. Outdoor Use Do not use the Sensor in locations subject to direct sunlight. Cleaning Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded. Surface Temperature Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the surrounding temperature and the power supply voltage. Use caution when operating or washing the Sensor. 10 Miniature Photoelectric Sensors E3H2 11 WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. [. . . ] CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3H2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3H2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag