[. . . ] switching output, alarm output, . . . ) Output circuit User set PNP (open collector), NPN (open collector) or complementary (push-pull) Output current max. 100 mA Voltage drop < 2. 0 V Residual current < 100 µA Circuit protection Reversed power supply, overload, short-circuit (pulsed)
A-86
Standard Photoelectric Sensors
Item E3NT-L17 E3NT-L37 E3NT-L27 E3NT-L47
Model E3NT-LH17 E3NT-LH37
E3NT-L@7-20
E3NT-R
E3NT
Inputs Input circuit Input pulse duration Analog Output
User set functions (e. g. teach-in, trigger, test, . . . ) Voltage input +10 V . . . 1 ms Current output 3. . 21mA: · 3 mA correspond to distance < 0. 2 m · 4 . . . [. . . ] For the 2-point window evaluation mode, two switching points must be set. Teaching the switching points in the normal mode The sensor is set at the factory for both outputs to BGS, light on. Place the target object in front of the sensor at the desired position. Teach the switching point for output 1: · Beginning with the key, press it simultaneously with the ENTER key. Threshold level is obtained and the output/ LED is updated. point B Enter in m with /
Output 1 Switch. point B set
Setting of Switching point C Output 2 2. ) 0 . . . 2. 5 m in 1 cm increments
Ad-C
Enter
Set Switch. point C Enter in m with /
Output 2 Switch. point C set
Setting of Switching point D 1. ) Output 2 2. ) 0 . . . 2. 5 m in 1 cm increments
Ad-d
Enter 2 s
Enter
Set Switch. point D Enter in m with /
Output 2 Switch. point D set
5Et
1. ) In the 2-point window evaluation mode, two switching points (A/B and C/D) can be set for each output. In the foreground and background suppression modes, only one switching point (A and C) can be set for each output. Then, only these switching points, A and C, can be set in the TEACH menu path. B and D switching points are not available. 2. ) If connector pin 2 is set as an input, only the switching points for Output 1 can be set.
A-92
Standard Photoelectric Sensors
SET menu
Menu items
Normal operation
Enter 2 s Enter 2 s
5Et
Enter 2 s
Function Output 1
0ut1
Enter
Select function with /
Background suppression Foreground suppression Window evaluation
b65 F65 2-P b65 F65 2-P
Enter
Select function with /
light-on dark-on
L-on d-on
Enter
Function Output 2 1. )
0ut2
Enter
Select function with /
Background suppression Foreground suppression Window evaluation
Enter
Select function with /
light-on dark-on
L-on d-on
Enter
Switch-on delay 2. ) 5. ) Output 1 0 . . . 9999 ms in 1 ms decrements
tr-1
Enter
Set time in ms with /
Enter
Switch-on delay Output 1 parameterised
Switch-off delay 2. ) 3. ) Output 1 0 . . . 9999 ms in 1 ms decrements
tF-1
Enter
Set time in ms with /
Enter
Switch-off delay Output 1 parameterised
Switch-on delay 2. ) 5. ) Output 2 1. ) 0 . . . 9999 ms in 1 ms decrements
tr-2
Enter
Set time in ms with /
Enter
Switch-on delay Output 2 parameterised
Switch-off delay 2. ) 3. ) Output 2 1. ) 0 . . . 9999 ms in 1 ms decrements
tF-2
Enter
Set time in ms with /
Enter
Switch-off delay Output 2 parameterised
Distance display
di5P
Enter
Select function with /
Absolute Bar graph
Ab5 bAr oFF on
Enter
Key lock 4. )
Enter 2 s
L0CH 0Pt
Enter
Select function with /
Locking OFF Locking ON
Enter
1. ) 2. ) 3. ) 4. )
If connector pin 2 is set as an input, the switch-on/off delay function canonly be set for Output 1. A second switching output is not available. [. . . ] If this should not be possible, the reflecting surface should not be parallel to the sensor's optical axis, but should be rotated by at least 10°. Mirror-like objects can cause malfunction inside and outside the sensing range. Avoid mirror-like objects in or close to the optical axis.
Inspection and Maintenance
Cleaning Do not use any scratching or abrasive cleaning materials. The protective pane of the optical system might get damaged. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3NT
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.