User manual OMRON E3NT DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3NT. We hope that this OMRON E3NT user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3NT.


Mode d'emploi OMRON E3NT
Download
Manual abstract: user guide OMRON E3NTDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] switching output, alarm output, . . . ) Output circuit User set PNP (open collector), NPN (open collector) or complementary (push-pull) Output current max. 100 mA Voltage drop < 2. 0 V Residual current < 100 µA Circuit protection Reversed power supply, overload, short-circuit (pulsed) A-86 Standard Photoelectric Sensors Item E3NT-L17 E3NT-L37 E3NT-L27 E3NT-L47 Model E3NT-LH17 E3NT-LH37 E3NT-L@7-20 E3NT-R E3NT Inputs Input circuit Input pulse duration Analog Output User set functions (e. g. teach-in, trigger, test, . . . ) Voltage input +10 V . . . 1 ms Current output 3. . 21mA: · 3 mA correspond to distance < 0. 2 m · 4 . . . [. . . ] For the 2-point window evaluation mode, two switching points must be set. Teaching the switching points in the normal mode The sensor is set at the factory for both outputs to BGS, light on. Place the target object in front of the sensor at the desired position. Teach the switching point for output 1: · Beginning with the key, press it simultaneously with the ENTER key. Threshold level is obtained and the output/ LED is updated. point B Enter in m with / Output 1 Switch. point B set Setting of Switching point C Output 2 2. ) 0 . . . 2. 5 m in 1 cm increments Ad-C Enter Set Switch. point C Enter in m with / Output 2 Switch. point C set Setting of Switching point D 1. ) Output 2 2. ) 0 . . . 2. 5 m in 1 cm increments Ad-d Enter 2 s Enter Set Switch. point D Enter in m with / Output 2 Switch. point D set 5Et 1. ) In the 2-point window evaluation mode, two switching points (A/B and C/D) can be set for each output. In the foreground and background suppression modes, only one switching point (A and C) can be set for each output. Then, only these switching points, A and C, can be set in the TEACH menu path. B and D switching points are not available. 2. ) If connector pin 2 is set as an input, only the switching points for Output 1 can be set. A-92 Standard Photoelectric Sensors SET menu Menu items Normal operation Enter 2 s Enter 2 s 5Et Enter 2 s Function Output 1 0ut1 Enter Select function with / Background suppression Foreground suppression Window evaluation b65 F65 2-P b65 F65 2-P Enter Select function with / light-on dark-on L-on d-on Enter Function Output 2 1. ) 0ut2 Enter Select function with / Background suppression Foreground suppression Window evaluation Enter Select function with / light-on dark-on L-on d-on Enter Switch-on delay 2. ) 5. ) Output 1 0 . . . 9999 ms in 1 ms decrements tr-1 Enter Set time in ms with / Enter Switch-on delay Output 1 parameterised Switch-off delay 2. ) 3. ) Output 1 0 . . . 9999 ms in 1 ms decrements tF-1 Enter Set time in ms with / Enter Switch-off delay Output 1 parameterised Switch-on delay 2. ) 5. ) Output 2 1. ) 0 . . . 9999 ms in 1 ms decrements tr-2 Enter Set time in ms with / Enter Switch-on delay Output 2 parameterised Switch-off delay 2. ) 3. ) Output 2 1. ) 0 . . . 9999 ms in 1 ms decrements tF-2 Enter Set time in ms with / Enter Switch-off delay Output 2 parameterised Distance display di5P Enter Select function with / Absolute Bar graph Ab5 bAr oFF on Enter Key lock 4. ) Enter 2 s L0CH 0Pt Enter Select function with / Locking OFF Locking ON Enter 1. ) 2. ) 3. ) 4. ) If connector pin 2 is set as an input, the switch-on/off delay function canonly be set for Output 1. A second switching output is not available. [. . . ] If this should not be possible, the reflecting surface should not be parallel to the sensor's optical axis, but should be rotated by at least 10°. Mirror-like objects can cause malfunction inside and outside the sensing range. Avoid mirror-like objects in or close to the optical axis. Inspection and Maintenance Cleaning Do not use any scratching or abrasive cleaning materials. The protective pane of the optical system might get damaged. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3NT

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3NT will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag