Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3NT-R. We hope that this OMRON E3NT-R user guide will be useful to you.
Lastmanuals help download the user guide OMRON E3NT-R.
Detailed instructions for use are in the User's Guide.
[. . . ] E29E-EN-01A
Retro-Reflective Sensor E3NT-R
Photoelectric Sensor
OPERATION MANUAL
Table of Contents
SECTION 1: Important Precautions . 3
1-1 1-2 1-3 1-4 1-5 1-6 Using the operating instructions . Use in accordance with the intended purpose . Use that is not in accordance with the intended purpose Warranty and liability . [. . . ] Deactivation of the sensor display reduces the sensor's current consumption by approximately 20 mA.
4-3-9 Reset
Reset returns the sensor to the factory default settings.
4-4 Inputs/Outputs
In total, the sensor can be operated with a maximum of three inputs/outputs. The functions of the inputs/outputs are user determined. Connector pin 4 is always defined as output (OUT). Connector pin 2 can be set as alarm output (ALARM), as test input (TEST). Connector pin 5 can be set as test input (TEST) or OFF.
4-4-1 Input: Test input TEST
Connector pins 2 or 5 can be set as test input. The emitter is deactivated if a signal in the operating voltage range is applied to this input. Depending on the absence of a detection object the sensor alters it's output, because no light is emitted.
18
SECTION 4: Function
4-4-2 Outputs
4-4-2-1 Switching output OUT
When a measured object is detected, the switching output OUT (Connector pin 4, fixed) switch in accordance with the sensor's output function settings.
4-4-2-2
Alarm output ALARM
Connector pin 2 can be set as the alarm output. The alarm output is switched on if the intensity of reflected light from the reflector is too low. In this case, the sensor may be covered with dust. Please clean the sensor and check the alarm output again. This condition is indicated by the red LED too.
4-4 Inputs/Outputs
19
20
SECTION 4: Function
SECTION 5: Transport
5-1 Packaging / Transportation damage
· · · · During transportation, please ensure that the sensor is not damaged by other objects. For transportation, only ever use the sensor's original packaging sealed properly. Keep the sensor's original packaging for later use. Report transportation damage immediately in writing to the haulage contractor and OMRON.
5-2
· ·
Storage
For storage keep the sensor in original packaging that has been sealed properly. Protect the sensor against dust and moisture.
5-3
· · ·
Scope of delivery
The sensor's scope of delivery consists of: Retro-reflective Sensor E3NT-R Short-form instruction sheet CD-ROM containing the S3 software, this operation manual, the S3 software manual and the Acrobat Reader software.
5-1 Packaging / Transportation damage
21
22
SECTION 5: Transport
SECTION 6: Mechanical installation of the sensor
6-1 Safety notes
Assembly, electrical connection and maintenance must only be carried out by instructed, trained and authorized specialist personnel in accordance with applicable regulations, after de-energizing the power supply and with the machine switched off. The machine must be safeguarded against reactivation. Conversions and changes and tampering in the interior of the sensor, the data interface and the alignment tool are forbidden. During assembly, do not knock the sensor or drop it. The ambient conditions at the assembly location must conform to the technical data (see SECTION 3: Specification).
6-2 Sensor assembly
For installation the following points should be considered: · · · · · · · The sensor is protected as far as possible against vibration and shock. The sensor is protected as far as possible against extraneous incident light. The sensor is protected as far as possible against damage and soiling. The sensor is installed in a way so that the electrical connection is possible. [. . . ] and keys.
For switching to the next main menu point: Press the Enter To skip a menu path, you can also press the Enter
key for 4 seconds.
9-1 Setting the sensor using the push buttons
Status LED
31
9-1-3 SET menu path
All function parameters of the sensor are defined in the SET menu path. The Status LED is on.
Menu items Normal operation Enter 2 s
Function of switching output
Enter
Select function with /
light-on
Enter
dark-on
Switch-on delay of switching output in ms (regarding to setting of delay function in OPT menu) Switch-off delay of switching output in ms (regarding to setting of delay function in OPT menu) minimum pulse width / constant pulse width of switching output in ms (regarding to setting of delay function in OPT menu)
Enter
Set time in ms with /
Enter
Switch-on delay parameterized
Enter
Set time in ms with /
Enter
Switch-off delay of switching output in ms (regarding to setting of delay function in OPT menu)
Enter
Set time in ms with /
Enter
Minimum pulse width / constant pulse width parameterized
Key lock Enter 2s
Enter
Select function with /
Locking OFF Locking ON
Enter
Remarks 1. If the delay-function is set to , , off" in the OPTIONS menu path, the switch-on/off delay parameters do not appear in the SET menu path. The On-delay-setting and the Off-delay-setting are only available if the switch-on/off delay in the OPTIONS menu path is set to "on-1". [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3NT-R
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3NT-R will begin.