[. . . ] Communication Unit For Digital Type Sensor
E3X-DRT21-S (DeviceNet)
User's Manual
Cat. Z223-E1-03
Introduction
This manual provides information regarding functions, performance and operating methods that are required for using Communication Unit for Digital Type Sensor E3X-DRT21-S (DeviceNet). This communication unit is a communication unit to be used for Digital Type Sensor E3X-DA-S Series, E3X-MDA Series, Digital Separate Amplifier Laser Sensor E3C-LDA Series, and Digital Separate Amplifier Proximity Sensor E2C-EDA Series, which had been developed with Omron's advanced technologies and successful experience.
Intended Audience
This manual is intended for the following personnel, who must also have knowledge of electrical systems (an electrical engineer or the equivalent). Personnel in charge of installing FA systems. [. . . ] Also, its data range is between F831Hex (complement of 2) and 0FA0Hex.
Read detection level + ON/OFF output
It reads the detection level of the sensor with the unit No. The data is shown in hexadecimal as a four-digit value (two bytes). If the data is negative, the 12th bit is 1 (on).
Detection level + ON/ OFF output
Bit 15
Bit 14
Bit 13
Bit 12 0: + / 1: -
Bit 11
Bit 10
Bit 09
Bit 08
Bit 07
Bit 06
Bit 05
Bit 04
Bit 03
Bit 02
Bit 01
Bit 00
0 *1 *2
Fixed
The detection level (000Hex to FA0Hex)
Bit Bit 14 (*2) Bit 15 (*1)
Description External input data ON/OFF output data
Data 0: No external input, 1: External input 0: OFF, 1: ON
E3X-DRT21-S
User's Manual
51
Section 3 Explicit Message Communications
Read threshold settings/read threshold settings on differentiation mode/read threshold settings on difference outputs
These commands read threshold settings of the sensor with the unit No. Data is shown in hexadecimal, and the data for each single unit is 16bits long. If the data is negative, the 12th bit is 1 (on).
Threshold settings
Bit 15
Bit 14
Bit 13
Bit 12 0: + / 1: -
Bit 11
Bit 10
Bit 09
Bit 08
Bit 07
Bit 06
Bit 05
Bit 04
Bit 03
Bit 02
Bit 01
Bit 00
Section 3 DeviceNet Communication Settings
0 Fixed
Threshold setting (0000Hex to 0FA0Hex)
Depending on the sensor type, [Read Differentiation Threshold Settings] and [Read Difference Threshold Settings] might not be able to be performed correctly.
Read Operating Mode Settings
It reads the operating mode settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 to 15 Description Operating mode No data Data E3X, E3C: 0: L/ON, 1: D/ON; E2C: 0: NO, 1: NC Always 0
52
E3X-DRT21-S
User's Manual
Section 3 Explicit Message Communications
Read Detection Function Settings
It reads the operating mode settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 02 03 to 15 No data Description Detection mode Data 0: STAND, 1: HI-RESO, 2: Differentiation, 4: High speed, 6: Tough(DA7) Always 0
Note that some models cannot be set to the high speed mode.
Read Differentiation Edge Settings
It reads the differentiation edge settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 to 15 Description Operating mode No data Data 0: Single-end edge, 1: Double-end edge Always 0
Section 3 DeviceNet Communication Settings
Read Differentiation Response Speed Settings
It reads the differentiation response speed settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 02 03 04 to 15 No data Description Differentiation response time Data 1: Differentiation response speed setting 1 2: Differentiation response speed setting 2 3: Differentiation response speed setting 3 4: Differentiation response speed setting 4 5: Differentiation response speed setting 5 Always 0
Read Timer Function Settings
It reads the timer function settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 Description Timer function Data 0: Timer function disabled 1: OFF-delay timer 2: ON-delay timer 3: One-shot timer 4: ON-delay and OFF-delay timer Always 0
02 to 15
No data
E3X-DRT21-S
User's Manual
53
Section 3 Explicit Message Communications
Read Timer Time Settings/Read ON-Delay timer time Settings/Read OFF-Delay timer time Settings
It reads the timer time settings of the sensor with the unit No. Its read data is expressed in hexadecimal and its length is two bytes; the data range is between 0000hex (0) and 1388hex (5000). When the timer function setting is OFF, [Read Timer Time Settings] command fails if the command is sent.
Read Display Switching
It reads the display switching settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 02 03 Description Display switching setting Data 0: Detection level and detection level (MDA) 1: Detection level and threshold 2: Detection level ratio and threshold 3: Peak on detected and bottom on undetected 4: Detection level at peak and detection level at bottom (time update) (E3X, E3C are bottom on detected and peak on undetected) 5. Analog bar 6: Detection level and peak digital values 7: Detection level and channel number 8: Count value (RM, LDARM) Always 0
Section 3 DeviceNet Communication Settings
04 to 15
No data
Read MODE Key Settings
It reads the MODE key settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 02 Description MODE key setting Data 0: E3X, E3C: Power tuning, E2C: Fine positioning 1: Zero reset 2: Counter reset (RM, LDARM) 3: Position teaching (E2C) 4: Teaching with the workpiece or without a workpiece Always 0
03 to 15
No data
Read Display Direction Settings
It reads the MODE key settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 04 to 15 Description Display direction setting No data Data 0: Normal, 1: Vertical reverse Always 0
54
E3X-DRT21-S
User's Manual
Section 3 Explicit Message Communications
Read Power Tuning Target Value Settings
It reads the power tuning target value settings of the sensor with the unit No. Its read data is expressed in hexadecimal and its length is two bytes; the data range is between 0064hex (100) and 0F3Chex (4000).
Read Output Settings
It reads the output settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 02 03 Description Output settings Data 0: Output for each channel 1: Area output (TW, LDATW, EDATW) 2: Self diagnosis output (TW, LDATW, EDATW) 3: AND output (MDA) 4: OR output (MDA) 5: Difference output (MDA) 6: Rising edge sync output (MDA) 7: Down edge sync output (MDA) 8: Head error output (E2C) Always 0
Section 3 DeviceNet Communication Settings
04 to 15
No data
Read Output Setting Timer Function Settings
It reads the output setting timer function settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 Description Output setting timer function Data 0: Timer function disabled 1: OFF-delay timer 2: ON-delay timer 3: One-shot timer Always 0
02 to 15
No data
Read Output Setting Timer Time Settings
It reads the output timer time settings of the sensor with the unit No. Its read data is expressed in hexadecimal and its length is two bytes; the data range is between 0000hex (0) and 1388hex (5000). When the output setting timer function setting is OFF, [Output Setting Timer Time Settings] command fails if the command is sent.
E3X-DRT21-S
User's Manual
55
Section 3 Explicit Message Communications
Read External Input Settings
It reads the output timer time settings of the sensor with the unit No. specified with the Instance ID.
Bit 00 01 02 03 Description Input setting Data 0: Teaching without a through-beam type workpiece 1: Teaching without a reflective type workpiece 2: Teaching with the workpiece or without a workpiece 3: Auto teaching 4: Power tuning (E3X, E3C) or fine positioning (E2C) 5: Zero reset 6: Projection lighting off (E3X, E3C) 7: Counter reset (RM, LDARM) 8: Sync detection input (E2C) 9: Position teaching Always 0
Section 3 DeviceNet Communication Settings
04 to 15
No data
Read External Input Memory Settings
It reads the external input memory settings of the sensor with the unit No. [. . . ] For a COS connection, data is periodically sent by the slave in a cycle determined by this setting even if the data has not changed, and checks that a communications error has not occurred. The higher the value is, the lesser the load on the network is. However, the time required to detect errors is longer with higher values.
E3X-DRT21-S
User's Manual
93
Section 4 DeviceNet Connection Settings
Step 6: Master I/O Allocations
1. Select [I/O Allocation (IN)] to display the following screen. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3X-DRT21-S
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.