User manual OMRON E3Z-H DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3Z-H. We hope that this OMRON E3Z-H user guide will be useful to you.

Lastmanuals help download the user guide OMRON E3Z-H.


Mode d'emploi OMRON E3Z-H
Download
Manual abstract: user guide OMRON E3Z-HDATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] --Both emitter and receiver: 3° to 15° Infrared LED (860 nm) emitter: 15 mA receiver: 20 mA 12 to 24 VDC ±10%, ripple (p-p) : 10% max. Load power supply voltage 26. 4 VDC max. , load current 100 mA max. (residual voltage 2 V max. ) Open collector output type (depends on the NPN/PNP output format), Light-ON/Dark-ON selectable by wiring Protection from load short-circuit and reversed power supply connection no adjustment Reverse polarity protection, output short-circuit protection, mutual interference prevention, output reverse protection Response time Sensitivity adjustment Ambient illuminance Ambient temperature Ambient humidity Insulation resistance Dielectric strength Vibration resistance Shock resistance Degree of protection Connection method Indicator lamp Weight Pre-wired (Packed models (with state) 2-m cable) Connector type Material Case Lens Accessories *1. Operation or reset: 1 ms max. Single-turn adjustment Incandescent lamp: 3, 000 lux max. Operating: -25°C to 55°C, Storage: -40°C to 70°C (with no icing or condensation) Operating: 35% to 85% RH, Storage: 35% to 95% RH (with no icing or condensation) 20 M min. [. . . ] Excess voltage may result in malfunction or fire. Never use the product with an AC power supply. Otherwise, explostion may result. Connecting and Mounting (1) The maximum power supply voltage is 24 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. (3) Use an extension cable with a minimum thickness of 0. 3 mm2 and less than 100 m long. (4) Do not pull on the cable with excessive force. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. (6)Mount the Sensor either using the bracket (sold separately) or on a flat surface. (7) Be sure to turn OFF the power supply before inserting or removing the connector. When cleaning the product, do not apply a high-pressure spray of water to one part of the product. Otherwise, parts may become damaged and the degree of protection may be degraded. Otherwise, the optical properties and degree of protection may be degraded. Water Resistance Do not use the Sensor in water, rainfall, or outdoors. Surface Temperature Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the surrounding temperature and the power supply voltage. Use caution when operating or washing the Sensor. E3Z-H 7 WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. [. . . ] CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the product may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3Z-H

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3Z-H will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag