Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E3ZM. We hope that this OMRON E3ZM user guide will be useful to you.
Lastmanuals help download the user guide OMRON E3ZM.
Detailed instructions for use are in the User's Guide.
[. . . ] Photoelectric sensor in compact stainless steel housing
E3ZM
E3ZM
· Compact size SUS 316L housing for highest mechanical protection · Tested detergent and chemical resistance (certified by Henkel-Ecolab) · Watertight construction for highest protection when cleaned with high pressure
Application
Detergent resistance
Product name
Concentration 1. 5 % 1. 5 % 2. 5 % 0. 3 % 6. 5 % 3. 0 % 5. 0 % 1. 0 %
Temperature 70 °C 70 °C 70 °C 25 °C 25 °C 70 °C 70 °C 25 °C 25 °C
Time 240 h 240 h 240 h 240 h 240 h 240 h 240 h 240 h 240 h
proven in intensive testing
Sodium hydroxide (NaOH) Potassium hydroxide (KOH) Phosphoric acid (H3PO4) Sodium hypochlorite (NaCIO) Hydrogen peroxide (H2O2) P3-topax-66s (Manufactured by Ecolab) P3-topax-56 (Manufactured by Ecolab) P3-oxonia active 90 (Manufactured by Ecolab)
TEK121 1. 1 % (Manufactured by ABC Compounding)
Product concept for highest machine hygiene
and often cleaned environments.
Waterproofing ring: Fluorine rubber
Excellent resistance to detergents and disinfectants.
Indicator cover: Polyether Sulfone (PES)
Excellent resistance to detergents and disinfectants.
Sensitivity adjustment and operation switch: Polyether etherketone (PEEK)
Excellent resistance to detergents and disinfectants. Also has excellent abrasion resistance.
Optical plate: Methacyrlic resin (PMMA)
Excellent resistance to detergents and disinfectants. High transparency and other qualities give PMMA excellent optical characteristics.
Case: SUS316L
Excellent corrosion resistance to many chemical reagents.
Seal
The seal provides the resistance to high-temperature and high-pressure water that complies with IP69K.
Cable: Vinyl chloride
Excellent resistance to detergents and disinfectants.
E3ZM
A-1
Ordering Information
Sensors
Sensor type Appearance Connection method Pre-wired (2 m) *2 Connector type (M8, 4 pins) *3 Pre-wired (2 m) *2 Connector type (M8, 4 pins) *3 Retroreflective (with M. S. R. function) Diffuse-reflective Pre-wired (2 m) *2 *4 Connector type (M8, 4 pins) *3 Pre-wired (2 m) *2 Connector type (M8, 4 pins) *3 Pre-wired (2 m) *2 Connector type (M8, 4 pins) *3 BGS reflective (fixed distance) Pre-wired (2 m) *2 Connector type (M8, 4 pins) *3 Pre-wired (2 m) *2 Connector type (M8, 4 pins) *3
(Using E39-R1S)
Red light
Infrared light
Sensing distance
Model NPN output PNP output E3ZM-T61 E3ZM-T81 E3ZM-T86 E3ZM-T83 E3ZM-T88 E3ZM-R81 E3ZM-R86 E3ZM-D82 E3ZM-D87
15m
E3ZM-T66
Through-beam *1
0. 8 m
with built-in slits
E3ZM-T63 E3ZM-T68
4m
[100mm]
*5
E3ZM-R61 E3ZM-R66 E3ZM-D62
1m
E3ZM-D67 E3ZM-LS61H E3ZM-LS81H
10 to 100 mm
E3ZM-LS66H E3ZM-LS86H E3ZM-LS62H E3ZM-LS82H
10 to 150 mm
E3ZM-LS67H E3ZM-LS87H E3ZM-LS64H E3ZM-LS84H
10 to 200 mm
E3ZM-LS69H E3ZM-LS89H
*1. [. . . ] Otherwise, explosion may result.
Rotation Torque for Sensitivity Adjustment and Selector Switch
Adjust with a torque of 0. 06 N·m or less.
Oily Environments
Do not use the Sensor in oily environments.
Modifications
Do not attempt to disassemble, repair, or modify the Sensor.
Outdoor Use
Do not use the Sensor in locations subject to direct sunlight.
Cleaning
When cleaning the product, do not apply a concentrated spray of water to one location. Otherwise, parts may become damaged and the degree of protection may be degraded. High-temperature environments may result in burn injury. Do not use thinner, alcohol, or other organic solvents. Otherwise, the optical properties and degree of protection may be degraded.
Washing
Do not use highly concentrated detergents. Do not use high-pressure water spray in excess of the specifications.
Surface Temperature
Burn injury may occur. The Sensor surface temperature rises depending on application conditions, such as the surrounding temperature and the power supply voltage. Use caution when operating or washing the Sensor.
Precautions for Safe Use
The following precautions must be observed to ensure safe operation of the Sensor.
Operating Environment
Do not use the Sensor in an environment where explosive or flammable gas is present.
Connecting Connectors
Be sure to hold the connector cover when inserting or removing the connector. Be sure to tighten the connector lock by hand; do not use pliers or other tools. If the tightening is insufficient, the degree of protection will not be maintained and the Sensor may become loose due to vibration. The appropriate tightening torque is 0. 3 to 0. 4 N·m.
E3ZM
A-11
Precautions for Safe Use
Do not install the Sensor in the following locations.
(1) Locations subject to direct sunlight (2) Locations subject to condensation due to high humidity (3) Locations subject to corrosive gas (4) Locations where the Sensor may receive direct vibration or shock
Load Short-circuit Protection
This Sensor is equipped with load short-circuit protection, but be sure to not short circuit the load. Be sure to not use an output current flow that exceeds the rated current. If a load short circuit occurs, the output will turn OFF, so check the wiring before turning ON the power supply again. The short-circuit protection circuit will be reset. The load shortcircuit protection will operate when the current flow reaches 1. 8 times the rated load current. When using an L load, use an inrush current of 1. 8 times the rated load current or higher.
Connecting and Mounting
(1) The maximum power supply voltage is 30 VDC. Before turning the power ON, make sure that the power supply voltage does not exceed the maximum voltage. (2) Laying Sensor wiring in the same conduit or duct as high-voltage wires or power lines may result in malfunction or damage due to induction. As a general rule, wire the Sensor in a separate conduit or use shielded cable. (3) Use an extension cable with a minimum thickness of 0. 3 mm2 and less than 100 m long. (4) Do not pull on the cable with excessive force. (5) Pounding the Photoelectric Sensor with a hammer or other tool during mounting will impair water resistance. [. . . ] SUITABILITY FOR USE THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. Please refer to separate catalogs for OMRON's safety rated products. OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the product. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E3ZM
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E3ZM will begin.