User manual OMRON E5C2 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E5C2. We hope that this OMRON E5C2 user guide will be useful to you.

Lastmanuals help download the user guide OMRON E5C2.


Mode d'emploi OMRON E5C2
Download
Manual abstract: user guide OMRON E5C2DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Analogue Temperature Controller E5C2 DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting · Compact, low-cost Temperature Controller. · Incorporates proportional control and reset adjustment function. · Consecutive mounting possible using mounting adapter. [. . . ] alumel Range °C 0 to 200 (5), 0 to 300 (10), 0 to 400 (10), 0 to 600 (20), 0 to 800 (20), 0 to 1, 000 (25), 0 to 1, 200 (25) 32 to 392 (10), 32 to 572 (20), 32 to 752 (20), 32 to 1, 112 (40), 32 to 1, 472 (50), 32 to 1, 832 (50), 32 to 2, 192 (50) L (IC) Iron vs. constantan 0 to 200 (5), 0 to 300 (10), 0 to 400 (10) Platinum resistance thermometer Pt100 ­50 to 50 (2), ­20 to 80 (2), 0 to 50 (1), 0 to 100 (2), 0 to 200 (5), 0 to 300 (10), 0 to 400 (10) 32 to 212 (5), 32 to 392 (10) Thermistor (see note 2) THE ­50 to 50 (2) (6 k at 0°C), 0 to 100 (2) (6 k at 0°C), 50 to 150 (2) (30 k at 0°C) °F 32 to 392 (10), 32 to 572 (20), 32 to 752 (20) --- Note: 1. Values in ( ) are the thermistor resistive value. Characteristics Setting accuracy Hysteresis Proportional band Control period Reset range (see note 1) Insulation resistance Dielectric strength Vibration resistance Shock resistance Life expectancy Ambient temperature Ambient humidity Degree of protection Weight ±2% FS max. (at 500 VDC) 2, 000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts Malfunction: 10 to 55 Hz, 0. 15-mm single amplitude for 10 min each in X, Y, and Z directions Destruction: 16. 7 Hz, 2-mm double amplitude for 2 hrs each in X, Y, and Z directions Malfunction: 147 m/s2, 3 times each in 6 directions Destruction: 294 m/s2, 3 times each in 6 directions Electrical: 100, 000 operations min. (3 A at 110 VAC, resistive load) Operating: ­10°C to 55°C (with no icing or condensation) Operating: 45% to 85% Front panel: IEC standard IP40 (see note 2) Terminals: IEC standard IP00 Approx. 200 g (with flush-mounting adapter) Note: 1. No reset function is incorporated by any E5C2 model with ON/OFF control. The model number of the special watertight cover conforming to IP66, NEMA4 is Y92A-48B. I-8 Analogue Temperature Controller E5C2 Nomenclature Temperature setting knob Operation indicator RESET adjustment shaft No reset function is incorporated by any E5C2 model with ON/OFF control. Operation Indicator Indicator Red Lit Not lit ON OFF Output Dimensions Note: All units are in millimeters unless otherwise indicated. 48 x 48 Terminal Arrangement (Bottom View) 44. 8 x 44. 8 Flush-mounting adapter Panel Y92F-30 Flush-mounting adapter P3G-08 Back connecting socket Tightening screw (96) (see note) Note: 109 mm for US08 Back Connecting Socket Panel Cutout Side-by-side Mounting of N Controllers N L 60 min. 2 93+1 0 3 141+1 0 4 189+1 0 5 237+1 0 6 285+1 0 Note: 1. Recommended panel thickness is 1 to 4 mm. Close side-by-side mounting is possible (in a single direction). Analogue Temperature Controller E5C2 I-9 Temperature Controller Dimensions with Flush-mounting Adapter (Accessory), and Back Connecting Socket (Sold Separately) Accessories (Order Separately) P2CF-08 Front Connecting Socket Eight, M3. 5 x 7. 5 sems Terminal Arrangement/ Internal Connections (Top View) Mounting Holes Two, 4. 5 dia. holes Note: Can also be mounted to a DIN track. 20 max. 50 max. Note: A finger-protection model (P2CF-08-E) is also available. P3G-08 Back Connecting Socket (for Flush Mounting) 27 dia. Terminal Arrangement/ Internal Connections (Bottom View) Note: A Protective Cover for finger protection (Y92A-48G) is also available. Protective Cover Y92A-48 The protective cover protects the front panel, particularly the setting section, against dust, dirt, and water drip. It also prevents the set values from being altered due to accidental contact with the setting keys. Appearance Model Y92A-48B Installation Connections Input Connect a thermocouple, the E52-THE@ Thermistor or platinum resistance thermometer to the E5C2 as shown in the following illustration. Output If the load circuit is a heating control system, be sure to connect the load to terminals 4 and 5. If the load circuit is a cooling control system, be sure to connect the load to terminals 4 and 6. [. . . ] To convert millimeters into inches, multiply by 0. 03937. To convert grams into ounces, multiply by 0. 03527. H081-E1-02 In the interest of product improvement, specifications are subject to change without notice. I-12 Analogue Temperature Controller E5C2 [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E5C2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E5C2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag