[. . . ] Analogue Temperature Controller
E5C2
DIN-sized (48 x 48 mm) Temperature Controller with Analog Setting
· Compact, low-cost Temperature Controller. · Incorporates proportional control and reset adjustment function. · Consecutive mounting possible using mounting adapter. [. . . ] alumel Range °C 0 to 200 (5), 0 to 300 (10), 0 to 400 (10), 0 to 600 (20), 0 to 800 (20), 0 to 1, 000 (25), 0 to 1, 200 (25) 32 to 392 (10), 32 to 572 (20), 32 to 752 (20), 32 to 1, 112 (40), 32 to 1, 472 (50), 32 to 1, 832 (50), 32 to 2, 192 (50) L (IC) Iron vs. constantan 0 to 200 (5), 0 to 300 (10), 0 to 400 (10) Platinum resistance thermometer Pt100 50 to 50 (2), 20 to 80 (2), 0 to 50 (1), 0 to 100 (2), 0 to 200 (5), 0 to 300 (10), 0 to 400 (10) 32 to 212 (5), 32 to 392 (10) Thermistor (see note 2) THE 50 to 50 (2) (6 k at 0°C), 0 to 100 (2) (6 k at 0°C), 50 to 150 (2) (30 k at 0°C)
°F
32 to 392 (10), 32 to 572 (20), 32 to 752 (20)
---
Note: 1. Values in ( ) are the thermistor resistive value.
Characteristics
Setting accuracy Hysteresis Proportional band Control period Reset range (see note 1) Insulation resistance Dielectric strength Vibration resistance Shock resistance Life expectancy Ambient temperature Ambient humidity Degree of protection Weight ±2% FS max. (at 500 VDC) 2, 000 VAC, 50/60 Hz for 1 min between charged terminals and uncharged metallic parts Malfunction: 10 to 55 Hz, 0. 15-mm single amplitude for 10 min each in X, Y, and Z directions Destruction: 16. 7 Hz, 2-mm double amplitude for 2 hrs each in X, Y, and Z directions Malfunction: 147 m/s2, 3 times each in 6 directions Destruction: 294 m/s2, 3 times each in 6 directions Electrical: 100, 000 operations min. (3 A at 110 VAC, resistive load) Operating: 10°C to 55°C (with no icing or condensation) Operating: 45% to 85% Front panel: IEC standard IP40 (see note 2) Terminals: IEC standard IP00 Approx. 200 g (with flush-mounting adapter)
Note: 1. No reset function is incorporated by any E5C2 model with ON/OFF control. The model number of the special watertight cover conforming to IP66, NEMA4 is Y92A-48B.
I-8
Analogue Temperature Controller E5C2
Nomenclature
Temperature setting knob
Operation indicator
RESET adjustment shaft No reset function is incorporated by any E5C2 model with ON/OFF control.
Operation Indicator
Indicator Red Lit Not lit ON OFF Output
Dimensions
Note: All units are in millimeters unless otherwise indicated.
48 x 48
Terminal Arrangement (Bottom View)
44. 8 x 44. 8
Flush-mounting adapter
Panel Y92F-30 Flush-mounting adapter P3G-08 Back connecting socket
Tightening screw (96) (see note)
Note: 109 mm for US08 Back Connecting Socket Panel Cutout Side-by-side Mounting of N Controllers N L
60 min.
2
93+1 0
3
141+1 0
4
189+1 0
5
237+1 0
6
285+1 0
Note: 1. Recommended panel thickness is 1 to 4 mm. Close side-by-side mounting is possible (in a single direction).
Analogue Temperature Controller
E5C2
I-9
Temperature Controller
Dimensions with Flush-mounting Adapter (Accessory), and Back Connecting Socket (Sold Separately)
Accessories (Order Separately)
P2CF-08 Front Connecting Socket
Eight, M3. 5 x 7. 5 sems
Terminal Arrangement/ Internal Connections (Top View)
Mounting Holes
Two, 4. 5 dia. holes
Note: Can also be mounted to a DIN track.
20 max.
50 max.
Note: A finger-protection model (P2CF-08-E) is also available.
P3G-08 Back Connecting Socket (for Flush Mounting)
27 dia.
Terminal Arrangement/ Internal Connections (Bottom View)
Note: A Protective Cover for finger protection (Y92A-48G) is also available.
Protective Cover Y92A-48
The protective cover protects the front panel, particularly the setting section, against dust, dirt, and water drip. It also prevents the set values from being altered due to accidental contact with the setting keys. Appearance
Model
Y92A-48B
Installation
Connections
Input
Connect a thermocouple, the E52-THE@ Thermistor or platinum resistance thermometer to the E5C2 as shown in the following illustration.
Output
If the load circuit is a heating control system, be sure to connect the load to terminals 4 and 5. If the load circuit is a cooling control system, be sure to connect the load to terminals 4 and 6. [. . . ] To convert millimeters into inches, multiply by 0. 03937. To convert grams into ounces, multiply by 0. 03527. H081-E1-02 In the interest of product improvement, specifications are subject to change without notice.
I-12