User manual OMRON E5ZE-8 D1 B-V2 DATASHEET

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON E5ZE-8 D1 B-V2. We hope that this OMRON E5ZE-8 D1 B-V2 user guide will be useful to you.

Lastmanuals help download the user guide OMRON E5ZE-8 D1 B-V2.


Mode d'emploi OMRON E5ZE-8 D1 B-V2
Download
Manual abstract: user guide OMRON E5ZE-8 D1 B-V2DATASHEET

Detailed instructions for use are in the User's Guide.

[. . . ] Refer to the List of Models for combinations of functions. Multipoint Temperature Controller E5ZE-8@D1@B-V2 1 Ordering Information List of Models No. of control points 8 Control method Control output Heater burnout and SSR failure detection Available (see note 2) Not available Available (see note 2) Not available Input type Thermocouple Platinum resistance thermometer E5ZE-8ACAD1PB-V2 Standard (see note 1) Heating and cooling Voltage Current Voltage Current (see note 3) E5ZE-8AQHD1TCB-V2 E5ZE-8AQHD1PB-V2 E5ZE-8ACAD1TCB-V2 E5ZE-8VQHD1TCB-V2 E5ZE-8VQHD1PB-V2 E5ZE-8VCAD1TCB-V2 E5ZE-8VCAD1PB-V2 Note: 1. Cooling control is possible by making a change in output operation. Models without the heater burnout/SSR failure detection function are also available. [. . . ] setting 1°C or 0. 1°C unit Platinum Resistance Thermometer Input (switch selectable) Range Setting no. setting unit Pt 100 (see note 1) ­100. 0 to 500. 0 ­100. 0 to 900. 0 0 1°C or 0. 1°C JPt 100 ­100. 0 to 500. 0 ­100. 0 to 900. 0 1 Note: 1. A temperature range is factory-set to a range of ­200° to 1, 300°C (for K(CA)) or ­100. 0° to 500. 0°C (for Pt 100). Thermocouple W is W/Re5-26 (tungsten rhenium 5, tungsten rhenium 26). °C °F Characteristics Measurement accuracy (see note) Thermocouple: (±0. 3% of the process value or ±2°C, whichever greater) ±1 digit max. (±0. 3% of the process value or ±3. 6°F, whichever greater) ±1 digit max. Platinum resistance thermometer: (±0. 3% of the process value or ±0. 8°C, whichever greater) ±1 digit max. (±0. 3% of the process value or ±1. 5°F, whichever greater) ±1 digit max. 0. 0° to 99. 9°C/°F for ON/OFF control only (in units of 0. 1°C/°F) 0. 0 to 10. 0 (in units of 0. 1) 0. 0° to 999. 9°C/°F (in units of 0. 1°C/°F) Cooling side: Cooling coefficient × Proportional band 0 to 3, 999 s (in units of 1 s) (for both heating and cooling) 0 to 3, 999 s (in units of 1 s) (for both heating and cooling) Heating side: Cooling side: 1 to 99 s (in units of 1 s) 1 to 99 s (in units of 1 s) Hysteresis Cooling coefficient Proportional band Integral (reset) time Derivative (rate) time Control period Sampling period Dead band/overlap band Alarm output setting range 200 ms for 8 control points ­999° to 999°C/°F (in units of 1°C/°F) ­999° to 9999°C/°F, 0 to 9999°C/°F (upper- and lower-limit alarm) (in units of 1°C/°F) ­999. 9° to 9999. 9°C/°F, 0. 0 to 9999. 9°C/°F (upper- and lower-limit alarm) (in units of 0. 1°C/°F) (see note 3) 0% to 99% (in units of 1%) 0. 2° to 999. 9°C/°F (in units of 0. 1°C/°F) 0. 02° to 99. 99°C/s or °F/s (in units of 0. 01°C/s or °F/s) Lithium battery 10 years min. provided that the ambient temperature is within the room temperature 20 M min. between the FG terminal and all analog input terminals (at 500 VDC) A leakage current of 1 mA AC max. with 500 VAC for 1 minutes between the FG terminal and all analog input terminals Malfunction: 10 to 55 Hz, 15 m/s2 for 8 min each in X, Y, and Z directions Destruction: 10 to 55 Hz, 20 m/s2 for 8 min each in X, Y, and Z directions Malfunction: 150 m/s2, 3 times each in 6 directions Destruction: 200 m/s2, 3 times each in 6 directions Operating: Storage: Operating: Storage: 0° to 55°C (with no icing or condensation) ­25° to 65°C (with no icing or condensation) 35% to 85% 35% to 95% Fuzzy strength Fuzzy scale 1 Fuzzy scale 2 Set value backup Set value backup period Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient humidity 4 Multipoint Temperature Controller E5ZE-8@D1@B-V2 Dimensions Enclosure rating Weight With casing: 173. 5 x 253 x 65 mm max. IP00 With casing:1, 700 g max. Note: 1. The measurement accuracy of the E5ZE used with a thermocouple B at 400°C or 750°F max. The following measurement accuracy values are applied to the E5ZE. and U: ±3°C ±1 digit max. and U: ±5. 4°F ±1 digit max. R, S, and W at 200°C max. , and B at 1, 000°C max. : ±4°C ±1 digit max. R, S, and W at 400°F max. , and B at 1, 800°F max. : ±7. 2°F ±1 digit max. The measurement accuracy of the E5ZE used with any thermocouple is 1°C/°F. The thermocouple can be used under the following temperature ranges to increase the measurement accuracy to as high as 0. 1°C/°F. [. . . ] The mounting brackets must be attached to the E5ZE with the four M3×6 screws provided with the E5ZE and each of the screws should be tightened to a torque of 0. 43 to 0. 58 N·m, or 4. 4 to 5. 9 kgf·cm. · Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. · Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. · Systems, machines, and equipment that could present a risk to life or property. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON E5ZE-8 D1 B-V2

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON E5ZE-8 D1 B-V2 will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag