[. . . ] Type L: S: M:
Elongated Sensor Small Sensor for NLPC and NSMC Miniature Sensor
2. Housing Material P: Plastic Housing M: Stainless Steel Housing 3: Contact configuration 20: 2 Normally Closed Contacts (NC) 21: 2 Normally Closed Contacts (NC) + 1 Normally Open Contact (NO) 4: Cable Length/connection 02: 2m Cable 05: 5m Cable 10: 10m Cable M1J8: M12 male connector, 8pin 4: Cable Length/connection for NMPC 02: 2m Cable, cable exit to the left 05: 5m Cable, cable exit to the left 10: 10m Cable, cable exit to the left M1J8: M12 male connector, 8-pin, cable exit to the left
F3S-TGR-N@C
1
Ordering Information
Elongated Sensors Type F3S-TGR-NLPC-20-02 F3S-TGR-NLPC-20-05 * F3S-TGR-NLPC-20-10 F3S-TGR-NLPC-20-M1J8 F3S-TGR-NLPC-21-02 F3S-TGR-NLPC-21-05 * F3S-TGR-NLPC-21-10 F3S-TGR-NLPC-21-M1J8 Cable Connection 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin Contact Configuration 2NC 2NC 2NC 2NC 2NC/1NO 2NC/1NO 2NC/1NO 2NC/1NO
*. Preferred stock items.
Small Sensor
Type F3S-TGR-NSMC-20-02 F3S-TGR-NSMC-20-05 * F3S-TGR-NSMC-20-10 F3S-TGR-NSMC-20-M1J8 F3S-TGR-NSMC-21-02 F3S-TGR-NSMC-21-05 * F3S-TGR-NSMC-21-10 F3S-TGR-NSMC-21-M1J8
Cable Connection 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin 2 m pre-wired 5 m pre-wired 10 pre-wired M12, 8-pin
Contact Configuration 2NC 2NC 2NC 2NC 2NC/1NO 2NC/1NO 2NC/1NO 2NC/1NO
*. [. . . ] EN954-1)
+24V
GND
Start
A1
A2 T31 KM1 Feedbackloop
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green brown orange
G9SB-2002-C
T11 T12 T22 T21
NO contact
KM2
T32
KM1
13
14
KM1
23
24
KM2 KM2
+Us GND
Series connection Application, up to 6 Sensors with G9SB-2002-C (up to safety Category 3 acc. EN954-1)
Magnetic Actuator F3S-TGR-NxxC Sensor
red blue black white yellow green
M
+24V
GND
Start
A1
A2 T31 KM1 Feedbackloop
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
G9SB-2002-C
T11 T12 T22 T21 T32
KM2
KM1
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
13
14
KM1
23
24
KM2 KM2
+Us GND
M
8
Safety Sensors / Components
G9SX Single Sensor Application with G9SX-AD322-T15 (up to Safety Category 4 acc. EN954-1)
+24V
GND
Start
A1 T33
A2 T31 KM1 Feedbackloop
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green brown orange
G9SX-AD322
T11 T12 T21 T22
NO contact
KM2
T32
KM1
S14
KM1
S24
KM2 KM2
M GND
Series connection Application, up to 6 Sensors with G9SX-AD322-T15 (up to Safety Category 3 acc. EN954-1) +24V
Magnetic Actuator F3S-TGR-NxxC Sensor
red blue black white yellow green
GND
Start
A1 T33
A2 T31 KM1 Feedbackloop
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
G9SX-AD322
T11 T12 T21 T22 T32
KM2
KM1
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
S14
KM1
S24
KM2 KM2
M GND
F3S-TGR-N@C
9
DeviceNet Safety NE1A and DST1-I/O-Terminals Single Sensor Application with NE1A and DST1-Safety-IO (up to safety Category 4 acc. EN954-1)
+24V
GND
V0
G0
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green brown orange
Test 0 In 0 Test 1 In 1
NO contact
NE1A-. . . DST1-ID DST1-MD DST1-MRD
Series connection Application, up to 6 Sensors with NE1A or DST1-Safety-IO (up to Safety Category 3 acc. EN954-1) +24V
Magnetic Actuator F3S-TGR-NxxC Sensor
red blue black white yellow green
GND
V0
G0
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
Test 0 In 0 Test 1 In 1
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
NE1A-. . . DST1-ID DST1-MD DST1-MRD
Application with multiple Sensors with NE1A or DST1-Safety-IO (up to Safety Category 4 acc. EN954-1)
Magnetic Actuator F3S-TGR-NxxC Sensor
red blue black white yellow green
+24V
GND
V0 Test 0 Test 1
G0
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
Test 2 In 0 In 1 In 2 In 3
Switch 1: Test 0 In 0 Test 1 In 1 Switch 2: Test 0 In 2 Test 2 In 3 Switch 3: Test 1 In 4 Test 2 In 5
Magnetic Actuator
F3S-TGR-NxxC Sensor
red blue black white yellow green
NE1A-. . . DST1-ID DST1-MD
In 4 In 5
10
Safety Sensors / Components
Safety Precautions
!WARNING
Be sure to turn OFF the power before performing wiring. Do not touch charge parts (e. g. , terminals) while power is ON. Do not allow the actuator to come close to the switch with the door open. Doing so may cause machinery to start operating and may result in injury. Keep actuators (magnets) away from magnetically sensitive equipment like PC harddisks, floppy disks etc. The magnetic field of the magnet will damage existing data.
Mutual Interference
If the switch and actuator are mounted in parallel, be sure to separate them by at least 25 mm, as shown below.
25 mm min. Switch Actuator Guard door Switch Actuator
Using for Hinged Doors
On hinged doors, install the Sensor at an opening edge as shown below.
!CAUTION
Use guard stops in the way shown below to ensure that the switch and actuator do not make contact when the guard door is closed.
Guard door Switch Guard Stops Actuator
CORRECT
2 mm
INCORRECT
Solvents
Ensure that solvents, such as alcohol, thinner, trichloroethane, or gasoline do not adhere to the product. [. . . ] Do not use power supplies with large ripples or power supplies that intermittently generate incorrect voltages. · Capacitors are consumable and require regular maintenance and inspection.
· Locations subject to direct sunlight · Locations subject to humidity levels outside the range 35% to 85% or subject to condensation due to extreme temperature changes · Locations subject to corrosive or flammable gases · Locations subject to shocks or vibration in excess of the product ratings · Locations subject to dust (including iron dust) or salts Take appropiate and sufficient countermeasures when using the product in the following locations. · · · · Locations subject to static electricity or other forms of noise Locations subject to possible exposure to radioactivity Locations subject to power supply lines It is advisable to mount the switches on non ferrous materials. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON F3S-TGR-N C
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON F3S-TGR-N C will begin.