[. . . ] OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED.
LIMITATIONS OF LIABILITY
OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR.
SUITABILITY FOR USE
THE PRODUCTS CONTAINED IN THIS DOCUMENT ARE NOT SAFETY RATED. THEY ARE NOT DESIGNED OR RATED FOR ENSURING SAFETY OF PERSONS, AND SHOULD NOT BE RELIED UPON AS A SAFETY COMPONENT OR PROTECTIVE DEVICE FOR SUCH PURPOSES. [. . . ] · Do not touch fluorescent or halogen lights while the power is ON or immediately after the power is turned OFF. · Dispose of this product as industrial waste. Regulations and Standards The Controller conforms to the following standards. EC Directive 89/336/EEC (EMC) EN standard (European Standard) EN61326 UL Standard UL61010-1
2
Precautions for Correct Use
Installation Site Install the product in a place that meets the following conditions: · Surrounding temperature of 0 to +50 °C · No rapid changes in temperature (place where dew does not form) · Relative humidity of between 35 to 85 % · No presence of corrosive or flammable gases · Place free of dust, salts and iron particles · Place free of vibration and shock · Place out of direct sunlight · Place where it will not come into contact with water, oils or chemicals Orientation of Product To improve heat dissipation, install the product in the following orientation only.
·
· ·
·
LCD integrated type
Do not install in this orientation.
Ambient Temperature · Maintain a minimum clearance of 50 mm above and below the controller to improve air circulation. A minimum clearance of 10 mm between other devices must also be maintained on the right and left sides of the product. However, if the adjacent devices do not generate heat, provide at least 50 mm of Box type clearance from the top of the Controller. For the clearance at the bottom and sides, follow the mounting method. · Do not install the product immediately above significant heat sources, such as heaters, transformers, or large-capacity resistors. · Do not let the ambient temperature exceed 50 °C (122 °F). · Provide a forced-air fan cooling or air conditioning if the ambient temperature is near 50 °C (122 °F) so that the ambient temperature never exceeds 50 °C (122 °F).
·
To reserve ventilation path, the feet must be mounted to the side panel that is positioned at the base. Do not install in this orientation.
Noise Resistance · Do not install the product in a cabinet containing high-voltage equipment. · Do not install the product within 200 mm of power cables. Component Installation and Handling · OMRON Components Use only the camera and cables designed specifically for the product. Failure to observe this may result in malfunction or damage of the product. · Connecting/Disconnecting Camera and Cables Always turn OFF the Controller's power before connecting or disconnecting a camera or cable. · Touching Signal Lines To prevent damage from static electricity, use a wrist strap or another device for preventing electrostatic discharges when touching terminals or signal lines in connectors. · Handling a USB Memory To remove a USB memory, make sure that data is not being read or written to it. The LED on the USB memory flashes while data is being read or written, so make sure that it is lit steadily before removing the memory. · Turning OFF the Power Do not turn OFF the power while a message is being displayed indicating that processing is being performed. Data in memory will be corrupted, and the product may not operate correctly the next time it is started. · Using the RESET Signal Do not use the RESET input immediately after power is turned ON. When using the RESET input to synchronize startup timing, wait at least 15 second after the Controller's power supply is turned ON before turning ON the RESET signal. [. . . ] 1 2 3 4
Use a shielded cable.
External device to be connected Pin No. * * * * Signal name SDA(-) SDB(+) RDB(+) RDA(-)
Use a compatible connector. · Recommended items
Manufacturer Plug Hood Model OMRON Corporation XM2A-0901 OMRON Corporation XM2S-0911
Pin numbers will depend on the external device being connected. Refer to the manual for the personal computer or PLC being connected.
·Connection Method
LCD integrated type Box type
Align the connector with the socket and press it straight into place, then fix it with the screws on both sides of the connector.
Turn OFF the power supply before connecting or disconnecting a Parallel I/O Cable. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON FZ2-55
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.