Manual abstract: user guide OMRON G2RS

Detailed instructions for use are in the User's Guide.

[. . . ] · High switching power (1-pole: 10 A). · Environment-friendly (Cd, Pb free). · Wide range of Sockets also available. Model Number Structure Model Number Legend G2R 1 LR 2 3 4 5 6 5. Classification Blank: General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button 7. [. . . ] operating frequency Insulation resistance Dielectric strength 100 m max. (w/built-in diode: 20 ms max. ) Mechanical: Electrical: AC: 15 ms max. ; DC: 10 ms max. (w/built-in diode: 20 ms max. ) 1 pole 2 poles 18, 000 operations/hr 1, 800 operations/hr (under rated load) 1, 000 M min. (at 500 VDC) 5, 000 VAC, 50/60 Hz for 1 min between coil and 5, 000 VAC, 50/60 Hz for 1 min between coil and contacts*; contacts*; 3, 000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1, 000 VAC, 50/60 Hz for 1 min between contacts of 1, 000 VAC, 50/60 Hz for 1 min between contacts of same polarity same polarity Electromechanical relays Vibration resistance Shock resistance Endurance Destruction: Malfunction: Destruction: Malfunction: Mechanical: Electrical: 10 to 55 to 10 Hz, 0. 75 mm single amplitude (1. 5 mm double amplitude) 10 to 55 to 10 Hz, 0. 75 mm single amplitude (1. 5 mm double amplitude) 1, 000 m/s2 200 m/s2 when energized; 100 m/s2 when not energized AC coil: 10, 000, 000 operations min. ; DC coil: 20, 000, 000 operations min. (at 18, 000 operations/hr) 100, 000 operations min. (at 1, 800 operations/hr under rated load) (DC coil type) ­40°C to 70°C (with no icing or condensation) 5% to 85% Ambient temperature Ambient humidity Weight Operating: Operating: Approx. 21 g Note: Values in the above table are the initial values. *4, 000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted. Approved Standards UL 508 (File No. E41643) Model Contact form Coil ratings 5 to 110 VDC 5 to 240 VAC Contact ratings 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-3 (NO contact only) 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) Operations 6 x 103 G2R-1-S SPDT IEC/VDE (EN61810) Contact form 1 pole Coil ratings 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC Contact ratings 5 A, 440 VAC (cos = 1. 0) 10 A, 250 VAC (cos = 1. 0) 10 A, 30 VDC (0 ms) 5 A, 250 VAC (cos =1. 0) 5 A, 30 VDC (0 ms) Operations 100 x 103 G2R-2-S DPDT 6 x 103 2 poles 100 x 103 CSA 22. 2 No. 0, No. 14 (File No. LR31928) Model Contact form Coil ratings 5 to 110 VDC 5 to 240 VAC Contact ratings 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-3 (NO contact only) 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) Operations 6 x 103 G2R-1-S SPDT LR Number of poles 1 pole Coil ratings 5 to 110 VDC 5 to 240 VDC Contact ratings 10 A, 250 VAC (general use) 7. 5 A, 250 VAC (PF0. 4) 10 A, 30 VDC (resistive) 5A, 30VDC (L/R=7ms) 5 A, 250 VAC (general use) 2 A, 250 VAC (PF0. 4) 5 A, 30 VDC (resistive) 3A, 30VDC (L/R=7ms) Operations 100 x 103 2 poles 6 x 103 G2R-2-S DPDT 5 to 110 VDC 5 to 240 VDC 100 x 103 General-purpose Relay G2RS G-7 Engineering Data Maximum Switching Power Plug-in Relays G2R-1-S 100 G2R-2-S 100 Switching current (A) Switching current (A) AC inductive load (cos = 0. 4) AC resistive load 10 DC resistive load DC inductive load (L/R = 7 ms) 10 AC inductive load (cos = 0. 4) AC resistive load DC resistive load 1 1 DC inductive load (L/R = 7 ms) 0. 1 1 10 100 1000 0. 1 1 10 100 1000 Switching voltage (V) Switching voltage (V) Endurance Plug-in Relays G2R-1-S Endurance (x103 operations) 5, 000 G2R-2-S 10, 000 Endurance (x103 operations) 5, 000 1, 000 500 250-VAC/30-VDC resistive load 250-VAC inductive load (cos = 0. 4) 1, 000 500 30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load 100 50 30-VDC inductive load (L/R = 7ms) 100 250-VAC 50 inductive load (cos = 0. 4) Switching current (A) Switching current (A) Ambient Temperature vs Maximum Coil Voltage Maximum voltage (%) DC coil AC coil Note: The maximum voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (°C) G-8 General-purpose Relay G2RS Technical and Environmental Properties Properties DIN-railing Resistance Environmental Protection Flammability Class Base 250 RT 1 Base, Insulator, Spool Case, Indicator, Pushbutton 2 8 mm 8 mm AgSnIn UL 94V-0 UL 94V-2 1-Pole and 2 Pole Model Pollution degree Creepage Distance Clearance Distance Contact Material Two-way action test button Relay in normal operation For momentary operation For lock operation 1 2 Pull down the test button to the first position, then press the yellow button with an insulated tool to operate the contact. Pull down the test button to the second position. (The contact is now in the locked position). Typical information for reference only The following data is provided as experimental and/or calculated data for reference only. These fall under the category of typical behaviour and the operation of individual relays will vary according to the exact operating conditions Typical Operate / Release times AC Type (operate / release time) DC Type (operate / release time) 6 / 8 ms 12 / 4 ms 1 pole model 6 / 10 ms 11 / 15 ms 2 pole model Multiple Contact DC Switching Capacity Load Reduction Factor 1 10 0. 8 Switching Current (A) Switching Current (A) Switching capacity of DC resistive load 0. 6 G2R-2-S 1 0. 4 2 contacts in series 1 0. 8 0. 6 0. 4 Cos(p. f. ) 0. 2 0. 1 20 40 60 80 100 120 G2R-1S 140 160 180 200 220 For AC inductive loads (such as solenoids, contactor coils, etc. ) the reduction factor corresponding to cos(p. f. ) (cosine of power factor) is multiplied by the rated current in order to identify the maximum allowable current. This approximation is not valid for loads with high inrush currents such as electric motors or fluorescent lamps. Switching Voltage (Vdc) General-purpose Relay G2RS G-9 Electromechanical relays Dimensions Note: All units are in millimeters unless otherwise indicated. Relays with Plug-in Terminals SPDT Relays G2R-1-S, G2R-1-SN, G2R-1-SNI G2R-1-SD, G2R-1-SND, G2R-1-SNDI Terminal Arrangement/Internal Connections (Bottom View) G2R-1-S 1 G2R-1-SD (DC) 29 max. 13 max. 1 5 35. 5 max. 2 4 3 5 2 4 3 G2R-1-SN, G2R-1-SNI (AC) G2R-1-SN, G2R-1-SNI (DC) 20 1 1 DC 24V 1 0. 5 4. 75 5 5 2 4 3 5 2 4 3 7. 5 G2R-1-SND, G2R-1-SNDI (DC) 5. 2 5. 2 17. 5 1 5 2 4 3 DPDT Relays G2R-2-S, G2R-2-SN, G2R-2-SNI G2R-2-SD, G2R-2-SND, G2R-2-SNDI Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S 1 2 3 4 G2R-2-SD (DC) 1 2 3 4 29 max. 13 max. 8 7 6 5 8 7 6 5 35. 5 max. G2R-2-SN, G2R-2-SNI (AC) 1 2 3 4 G2R-2-SN, G2R-2-SNI (DC) 1 2 3 4 6. 2 0. 5 2. 5 2. 4 20 8 7 6 5 8 7 6 5 7. 4 8. 9 G2R-2-SND, G2R-2-SNDI (DC) 5 5 19. 4 1 2 3 4 8 7 6 5 G-10 General-purpose Relay G2RS DIN-rail/Surface Mounting Sockets P2RF-05-S 38. 2 max. Terminal Arrangement (Top View) 11 32. 6 27. 6 22. 6 12 14 92. 0 max. 35. 4 24. 5 A1 A2 Standard model Option (with ejector and label attached) 28. 5 18. 0 max. 36. 5 max. Terminal Arrangement (Top View) 21 11 32. 6 27. 6 22. 6 (3. 4) 24 14 22 12 92. 0 max. 35. 4 A1 A2 Standard model Option (with ejector and label attached) 28. 6 18. 0 max. 32. 6 (5. 3) Accessories for P2RF-@-S Socket Bridge Insulating coating Clip and Release Lever 9 L 1. 2 dia. conductor (See note 1. ) 14 16. 8 40. 35 General-purpose Relay G2RS 36 G-11 Electromechanical relays 24. 5 P2RF-05-E Five, M3. 5×7 48 max. [. . . ] Doing so may cause damage to internal components (e. g. , deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. · Do not insert the screwdriver at an angle. Doing so may break the side of the socket and result in a short-circuit. General-purpose Relay G2RS G-15 Electromechanical relays ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G2RS

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON G2RS will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag