[. . . ] · Operation indicator provided to confirm input (model numbers with "N" before the suffix).
Model Number Structure
Model Number Legend
G3F-Zero Cross Function Blank: Equipped with zero cross functions L: Not equipped with zero cross function 6. Operation Indicator Blank: Not equipped with operation indicator N: Equipped with operation indicator 7. [. . . ] When ordering, specify the rated input voltage. 4 to 24 VDC G3FD-X03S-VD G3FD-102S-VD G3F-203S-VD G3F-203SL-VD G3FD-X03SN-VD G3FD-102SN-VD G3F-203SLN-VD Model G3F-203SN-VD G3F-202SN-VD
Accessories (Order Separately)
Connecting Sockets
Refer to page 297 for details. Item Connecting Mounting method/ Terminal type Hold-down clip PYF08A-E Front connecting Track mounted/ screw terminals PYC-A1 PY08 Back connecting Solder terminals PYC-P PCB terminals Wrapping terminals PY08-02 PY08QN(2)
Specifications
Ratings (at an Ambient Temperature of 25°C)
Input
Model G3F-203SN-VD G3F-202SN-VD Rated voltage 5 to 24 VDC 100/110 VAC 200/220 VAC Operating voltage 4 to 28 VDC 75 to 125 VAC 150 to 250 VAC Impedance 15 mA max. 41 k±20% 72 k±20% 75 VAC max. Voltage level Must operate voltage Must release voltage 1 VDC min. 40 VAC min.
Solid State Relays G3@-VD
G3F/G3FD
215
Model G3F-203SLN-VD
Rated voltage 5 VDC 12 VDC 24 VDC
Operating voltage 4 to 6 VDC 9. 6 to 14. 4 VDC 19. 2 to 28. 8 VDC 4 to 28 VDC 4 to 28 VDC 75 to 125 VAC 150 to 250 VAC 3 to 28 VDC 4 to 6 VDC 9. 6 to 14. 4 VDC 19. 2 to 28. 8 VDC 3 to 28 VDC
Impedance 390 ±20% 900 ±20% 2 k±20% 1. 5 k+20%/10% 1. 5 k
+20%
Voltage level Must operate voltage 4 VDC max. Must release voltage 1 VDC min.
G3FD-X03SN-VD G3FD-102SN-VD
5 to 24 VDC 5 to 24 VDC 100/110 VAC 200/220 VAC
/10%
41 k±20% 72 k±20% 390 ±20% 900 ±20% 2 k±20% 1. 5 k+20%/10%
G3F-203S-VD G3F-203SL-VD
4 to 24 VDC 5 VDC 12 VDC 24 VDC
15 mA max. (See note. ) 3 VDC max.
G3FD-X03S-VD G3FD-102S-VD
4 to 24 VDC
Note: Constant-current input circuit.
Output
Model G3F-203SN-VD G3F-203SLN-VD G3F-203S-VD G3F-203SL-VD G3F-203SN-VD G3FD-X03SN-VD G3FD-X03S-VD G3FD-102SN-VD G3FD-102S-VD Rated load voltage 100 to 240 VAC Applicable load Load voltage range 75 to 264 VAC Load current 0. 1 to 3 A Inrush current 45 A (60 Hz, 1 cycle)
100 to 240 VAC 4 to 48 VDC 5 to 110 VDC
75 to 264 VAC 3 to 52. 8 VDC 3 to 125 VDC
0. 1 to 2 A 0. 1 to 3 A 0. 1 to 2 A
45 A (60 Hz, 1 cycle) 18 A (10 ms) 10 A (10 ms)
216
Solid State Relays G3@-VD G3F/G3FD
Characteristics
Item G3F-203SN-VD G3F-202SN-VD G3F-203S-VD G3F-203SLN-VD G3F-203SL-VD G3FD-X03SN-VD G3FD-X03S-VD 0. 5 ms max. G3FD-102SN-VD G3FD-102S-VD
Operate time
1 ms max. 1/2 of load power source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. 1/2 of load power 1/2 of load power source cycle + 1 ms source cycle + 1 ms max. (DC input) 3/2 of load power source cycle + 1 ms max. (AC input)
Output ON voltage drop Leakage current
0. 1 mA max. (at 100 VDC)
Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Ambient humidity Certified standards Weight
100 M min. (at 500 VDC) 2, 000 VAC, 50/60 Hz for 1 min Destruction: 1, 000 m/s2 Operating: 30°C to 80°C (with no icing or condensation) Storage: 30°C to 100°C (with no icing or condensation) Operating: 45% to 85% G3F: UL508, CSA C22. 2 No. [. . . ] Install the Relays so that they are adequately ventilated. If poor ventilation is unavoidable, reduce the load current by half.
Protective Terminal
When using for AC inductive loads, connect the load terminals of the SSR to an inrush absorber (varistor).
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G3FD
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.