Manual abstract: user guide OMRON G3PA

Detailed instructions for use are in the User's Guide.

[. . . ] Zero Cross Function Blank: Equipped with zero cross function L: Not equipped with zero cross function 6. Certification VD: Certified by UL, CSA, and VDE 7. Special Specifications Blank: Standard models 2: 480-V models Solid State Relays G3PA J-21 SSR Ordering Information List of Models Model G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 Yes No Isolation Phototriac coupler Yes Zero cross function Yes Indicator Rated output load 10 A at 24 to 240 VAC 20 A at 24 to 240 VAC 40 A at 24 to 240 VAC 60 A at 24 to 240 VAC 10 A at 24 to 240 VAC 20 A at 24 to 240 VAC 40 A at 24 to 240 VAC 60 A at 24 to 240 VAC 10 A at 24 to 240 VAC 20 A at 24 to 240 VAC 40 A at 24 to 240 VAC 60 A at 24 to 240 VAC 20 A at 180 to 400 VAC 30 A at 180 to 400 VAC 20 A at 200 to 480 VAC 30 A at 200 to 480 VAC 50 A at 200 to 480 VAC 12 to 24 VDC 24 VAC Rated input voltage 5 to 24 VDC Note: When ordering, specify the rated input voltage. Replacement Parts Name Power Device Cartridge Carry current 10 A Load voltage range 19 to 264 VAC Model G32A-A10-VD DC5-24 G32A-A10L-VD DC5-24 G32A-A10-VD AC24 20 A G32A-A20-VD DC5-24 G32A-A20L-VD DC5-24 G32A-A20-VD AC24 40 A G32A-A40-VD DC5-24 G32A-A40L-VD DC5-24 G32A-A40-VD AC24 60 A G32A-A60-VD DC5-24 G32A-A60L-VD DC5-24 G32A-A60-VD AC24 20 A 30 A 20 A 30 A 50 A 180 to 528 VAC 150 to 440 VAC G32A-A420-VD DC12-24 G32A-A430-VD DC12-24 G32A-A420-VD-2 DC12-24 G32A-A430-VD-2 DC12-24 G32A-A450-VD-2 DC12-24 Applicable SSR G3PA-210B-VD DC5-24 G3PA-210BL-VD DC5-24 G3PA-210B-VD AC24 G3PA-220B-VD DC5-24 G3PA-220BL-VD DC5-24 G3PA-220B-VD AC24 G3PA-240B-VD DC5-24 G3PA-240BL-VD DC5-24 G3PA-240B-VD AC24 G3PA-260B-VD DC5-24 G3PA-260BL-VD DC5-24 G3PA-260B-VD AC24 G3PA-420B-VD DC12-24 G3PA-430B-VD DC12-24 G3PA-420B-VD-2 DC12-24 G3PA-430B-VD-2 DC12-24 G3PA-450B-VD-2 DC12-24 VDE certification Yes Other Units (Order Separately) Units that Enable 2-line Switching of 3-phase Power Name Short-circuit Unit 10 A 20 A 30 A 40 A G32A-D40 Current flow G32A-D20 Model Applicable SSR G3PA-210B-VD, G3PA-210BL-VD G3PA-220B-VD, G3PA-220BL-VD G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 G3PA-240B-VD, G3PA-240BL-VD J-22 Solid State Relays G3PA Specifications Ratings (at an Ambient Temperature of 25°C) Input Model G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-210BL-VD G3PA-220BL-VD G3PA-240BL-VD G3PA-260BL-VD G3PA-210B-VD G3PA-220B-VD G3PA-240B-VD G3PA-260B-VD G3PA-420B-VD G3PA-430B-VD G3PA-420B-VD-2 G3PA-430B-VD-2 G3PA-450B-VD-2 12 to 24 VDC 9. 6 to 30 VDC 7 mA max. 24 VAC 19. 2 to 26. 4 VAC 1. 4 k±20% 19. 2 VAC max. [. . . ] Insert the cartridge into the opening of the G3PA so that the letters on the cartridge and those on the G3PA are in the same direction and side A and side B are even. Side A Side B Mounting Follow the procedures below to mount the Power Device Cartridge on the G3PA. Apply silicone grease (provided with the G32A-A) to the entire surface of the heat sink. Switch on the power and check the G3PA to be sure it works properly. G32A-A40(L)-VD/G32A-A60(L)-VD/G32A-A430-VD(-2)/G32A-A450-VD-2 The G32A Power Device Cartridge is mounted and secured with screws to the G3PA Unit. Extraction Follow the procedures below to dismount the G32A-A Power Device Cartridge from the G3PA. Loosen the two centered screws on the sides to dismount the cartridge. The screws are connected to terminals 1 and 2. Mounting 1. Apply silicone grease to the entire surface of the heat sink. Loosen Apply silicone grease here. 2. Make sure that there is no dust or pieces of wire on the heat sink of the G32A-A or the G3PA. Loosen 4. Loosen the screws on both the corners. Loosen Loosen 5. Hold the indented part of both the corners to dismount the cartridge. J-26 Solid State Relays G3PA 3. Insert the cartridge into the opening of the G3PA so that side A and side B are even. Side A 4. Tighten the screws on both the corners with a tightening torque of 0. 59 to 0. 78 N·m. Tighten the screws on both the sides with a tightening torque of 0. 59 to 0. 78 N·m. Switch on the power and check the G3PA to be sure it works properly. Side B Linking Terminal Connection · Connecting with linking terminal for G3PA-210B(L)-VD, -220B(L)VD, -240B(L)-VD and G3PA-420B-VD(-2), G3PA-430B-VD(-2). SSR1 SSR2 SSR1 SSR2 · Connecting with linking terminal for G32A. SSR G32A Unit SSR G32A Unit * * The cover will not fit if the terminal protrudes. When SSRs are close mounted, loosen the M3. 5 Sems screw and flip the linking terminal down. Insert the linking terminal securely into the center of the screw and tighten the screw. When SSR are close mounted, loosen the M3. 5 Sems screw on the G32A and flip the linking terminal down. Insert the linking terminal securely into the center of the screw and tighten the screw. Ensure that the linking terminal does not protrude. Connect the terminal with power off. Linking terminal Refer to the instruction manual for the G32A-A Power Device Cartridge to replace the G3PA's triac part. Linking terminal G3PA-420B-VD Linking terminal Linking terminal When the temperature indicator has turned from pink to red, the G32-A-A Power Device Cartridge may have malfunctioned, in which case the cartridge must be replaced with a new one. Use the terminal cover to prevent accidents due to electric shock. Solid State Relays G3PA J-27 SSR Engineering Data Load Current vs. Ambient Temperature Vertical Mounting Panel Ground G3PA-210B(L)-VD, G3PA-220B(L)-VD G3PA-220B(L)-VD 25 G3PA-240B(L)-VD G3PA-260B(L)-VD 80 Load current (A) Load current (A) Load current (A) 60 G3PA-210B(L)-VD 15 40 25 20 -30 -20 0 20 40 60 80 100 Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) G3PA-420B-VD, G3PA-420B-VD-2 G3PA-430B-VD, G3PA-430B-VD-2 G3PA-450B-VD-2 Load current (A) Load current (A) Ambient temperature (°C) Ambient temperature (°C) Load current (A) Ambient temperature (°C) Note: Close mounting is possible for a maximum of three Units by reducing the load current by 20%. (A minimum clearance of 10 mm must be provided when mounting four or more Units. ) J-28 Solid State Relays G3PA Input Voltage vs. [. . . ] (Generally, each 10 °C reduction in temperature will double the expected life. ) Load current (A) 10 A 20 A 0. 31 30 A 0. 47 40 A 0. 62 60 A 0. 93 Required number of fans 0. 16 per SSR SSR Mounting direction Vertical direction 60 mm min. Between duct or airflow obstruction and SSR 30 mm min. Example: For 10 SSRs with load currents of 20 A, 0. 31 x 10 = 3. 1 Thus, 4 fans would be required. Size of fans: 92 mm2, Air volume: 0. 7 m3/min, Ambient temperature of control panel: 30 °C If there are other instruments that generate heat in the control panel other than SSRs, additional ventilation will be required. 80 mm min. Space between SSRs Close Mounting min. Relationship between SSRs and Ducts Duct Height Countermeasure (1) 50 mm max. Duct or airflow obstruction Mounting surface G3PA Vertical direction Mounting surface Countermeasure (2) Mounting surface (A height of no more than half the SSR's height is recommended. ) G3PA G3PA Airflow Duct or airflow obstruction Do not surround the SSR with ducts, otherwise the heat radiation of the SSR will be adversely affected. Use short ducts. If the ducts cannot be shortened, place the SSR on a metal base so that it is not surrounded by the ducts. Ventilation Be aware of air flow Duct or air flow obstruction Ventilation outlet G3PA G3PA G3PA Air inlet If the air inlet or air outlet has a filter, clean the filter regularly to prevent it from clogging and ensure an efficient flow of air. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G3PA

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON G3PA will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag