User manual OMRON G3R-I-O

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON G3R-I-O. We hope that this OMRON G3R-I-O user guide will be useful to you.

Lastmanuals help download the user guide OMRON G3R-I-O.


Mode d'emploi OMRON G3R-I-O
Download
Manual abstract: user guide OMRON G3R-I-O

Detailed instructions for use are in the User's Guide.

[. . . ] · Incorporate an easy-to-see monitoring indicator. · -UTU models certified by UL, CSA, and TÜV. Model Number Structure Model Number Legend G3R-Rated Load Current R1: 0. 1 A 01: 1A 02: 2A 6. [. . . ] Must operate voltage Must release voltage 60 VAC max. 3. 6 VDC min. Output Model G3R-IAZR1SN-UTU G3R-IDZR1SN-UTU G3R-IDZR1SN-1-UTU SSR Rated voltage Operating voltage 4 to 32 VDC Input current 15 mA max. Must operate voltage Must release voltage 4 VDC max. Rated load voltage 100 to 240 VAC 5 to 48 VDC 48 to 200 VDC Load voltage range 75 to 264 VAC 4 to 60 VDC 40 to 200 VDC Load current (See note. ) 0. 05 to 2 A 0. 01 to 2 A 0. 01 to 1. 5 A Inrush current 30 A (60 Hz, 1 cycle) 8 A (10 ms) 8 A (10 ms) Logic level supply voltage 4 to 32 VDC Logic level supply current 0. 1 to 100 mA Output Module Input Model G3R-OA202SLN-UTU G3R-ODX02SN-UTU G3R-OD201SN-UTU G3R-OA202SZN-UTU 5 to 24 VDC Output Model G3R-OA202SZN-UTU G3R-OA202SLN-UTU G3R-ODX02SN-UTU G3R-OD201SN-UTU Note: The minimum current value is measured at 10°C min. Solid State Relays G3R-I/O J-69 Characteristics Input Module Item Operate time Release time Response frequency Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Certified standards G3R-IAZR1SN-UTU 20 ms max. between input and output 4, 000 VAC, 50/60 Hz for 1 min between input and output 10 to 55 to 10 Hz, 0. 75-mm single amplitude 1, 000 m/s2 Operating: ­30°C to 80°C (with no icing) Storage: ­30°C to 100°C (with no icing) UL508 File No. R9650094 (EN60950) Operating: 45% to 85% Approx. 10 Hz Ambient humidity Weight Output Module Item Operate time Release time Response frequency Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Certified standards G3R-OA202SZN-UTU G3R-OA202SLN-UTU G3R-ODX02SN-UTU 1 ms max. G3R-OD201SN-UTU 1/2 of load power source 1 ms max. 1/2 of load power source cycle + 1 ms max. between input and output 4, 000 VAC, 50/60 Hz for 1 min between input and output Destruction: 10 to 55 to 10 Hz, 0. 75-mm single amplitude Destruction: 1, 000 m/s2 Operating: ­30°C to 80°C (with no icing) Storage: ­30°C to 100°C (with no icing) UL508 File No. R9650094 (EN60950) Operating: 45% to 85% Approx. 18 g Ambient humidity Weight J-70 Solid State Relays G3R-I/O Engineering Data Load Current vs. Ambient Temperature G3R-OA202SZN-UTU/OA202SLN-UTU G3R-ODX02SN-UTU (4 to 60 VDC) G3R-OD201SN-UTU (40 to 200 VAC) 2 4-point mounting (see note 1) 2 4-point mounting (see note 1) 2 Load current (A) Load current (A) 1. 5 1. 4 1 0. 7 0. 5 16-point mounting (see note 2) Single-point mounting Load current (A) 1. 5 1. 4 1 16-point mounting (see note 2) Single-point mounting 1. 5 1. 1 1 4-point mounting (see note 1) 16-point mounting (see note 2) 0. 6 0. 5 Single-point mounting 0. 5 -30 -20 0 20 30 40 55 60 80 100 -30 -20 0 20 40 55 60 80 100 -30 -20 0 20 40 55 60 80 100 Ambient temperature (°C) Ambient temperature (°C) Ambient temperature (°C) Note: 1. When G70A-Z0C16 is mounted. One Cycle Surge Current: Non-repetitive Note: Keep the inrush current to half the rated value if it occurs repetitively. G3R-OA202SZN-UTU/OA202SLN-UTU G3R-ODX02SN-UTU 10 9 10 9 8 G3R-OD201SN-UTU 30 8 Inrush current (A) Inrush current (A) 7 6 5 4 3 2 1 Inrush current (A) 10 30 50 100 300 500 1000 2000 7 6 5 4 3 2 1 0 10 30 50 100 300 500 1000 2000 20 10 10 30 50 100 200 500 1000 5000 0 Energized time (ms) Energized time (ms) Energized time (ms) Solid State Relays G3R-I/O J-71 SSR Dimensions Note: All units are in millimeters unless otherwise indicated. G3R 1 3 0. 5 29 max. 5. 2 Terminal Arrangement/ Internal Connections (Bottom View) (+) 3 4 9. 6 17. 4 (-) 4. 75 1 5 4 Load 13 max. 4 10 28 max. 5 0. 5 4. 75 7. 5 4. 7 Input 1 5 (-) 2 20 (+) Connecting Sockets Connecting Socket Attaching Plates P2RF-05 Five, M3. 5×8 4 dia. P2RF-05 Socket 58. 5 * M3 (M3 x16) or 3. 2-dia. [. . . ] (See note. ) Rated voltage Model G70A-ZOC16-3 G70A-ZOC16-4 G70A-ZIM16-5 Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range. Dimensions Note: All units are in millimeters unless otherwise indicated. G70A-ZOC16 (Output) 234 64 75 +0. 2 35. 3-0 28. 6 13. 5 M3. 5 9. 2 18. 4 48. 7 20. 7 34. 2 G70A-ZIM16 (Input) 234 48. 7 10. 2 +0. 2 35. 3-0 75 13. 5 M3. 5 9. 2 19. 6 64 20. 7 34. 2 J-74 Solid State Relays G3R-I/O Terminal Arrangement/Internal Connection G70A-ZOC16-3 (NPN) - + - + (+) (-) Connector Terminal Arrangement (Top View) G70A-ZOC16-4 (PNP) (+) (-) Connector Terminal Arrangement (Top View) Solid State Relays G3R-I/O J-75 SSR - + - + G70A-ZIM16-5 (NPN/PNP) - + 1A1 2A1 1A2 2A2 3A1 4A1 3A2 5A1 4A2 6A1 5A2 7A1 6A2 8A1 7A2 9A1 8A2 10A1 9A2 11A1 10A2 12A1 11A2 13A1 12A2 14A1 13A2 15A1 14A2 16A1 15A2 16A2 - + COM. Connector Terminal Arrangement (Top View) Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Protective Element Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load. Connection With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR. Precaution of Mounting Output Modules With up to four G3R SSRs mounted closely and side by side, 2-A loads can be switched. With a G3R SSRs mounted every other slot, 2-A loads can be switched. G3R G3R G3R ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G3R-I-O

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON G3R-I-O will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag