[. . . ] · Incorporate an easy-to-see monitoring indicator. · -UTU models certified by UL, CSA, and TÜV.
Model Number Structure
Model Number Legend
G3R-Rated Load Current R1: 0. 1 A 01: 1A 02: 2A 6. [. . . ] Must operate voltage Must release voltage 60 VAC max. 3. 6 VDC min.
Output
Model G3R-IAZR1SN-UTU G3R-IDZR1SN-UTU G3R-IDZR1SN-1-UTU SSR Rated voltage Operating voltage 4 to 32 VDC Input current 15 mA max. Must operate voltage Must release voltage 4 VDC max. Rated load voltage 100 to 240 VAC 5 to 48 VDC 48 to 200 VDC Load voltage range 75 to 264 VAC 4 to 60 VDC 40 to 200 VDC Load current (See note. ) 0. 05 to 2 A 0. 01 to 2 A 0. 01 to 1. 5 A Inrush current 30 A (60 Hz, 1 cycle) 8 A (10 ms) 8 A (10 ms) Logic level supply voltage 4 to 32 VDC Logic level supply current 0. 1 to 100 mA
Output Module
Input
Model G3R-OA202SLN-UTU G3R-ODX02SN-UTU G3R-OD201SN-UTU G3R-OA202SZN-UTU 5 to 24 VDC
Output
Model G3R-OA202SZN-UTU G3R-OA202SLN-UTU G3R-ODX02SN-UTU G3R-OD201SN-UTU
Note: The minimum current value is measured at 10°C min.
Solid State Relays
G3R-I/O
J-69
Characteristics
Input Module
Item Operate time Release time Response frequency Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Certified standards G3R-IAZR1SN-UTU 20 ms max. between input and output 4, 000 VAC, 50/60 Hz for 1 min between input and output 10 to 55 to 10 Hz, 0. 75-mm single amplitude 1, 000 m/s2 Operating: 30°C to 80°C (with no icing) Storage: 30°C to 100°C (with no icing) UL508 File No. R9650094 (EN60950) Operating: 45% to 85% Approx. 10 Hz
Ambient humidity Weight
Output Module
Item Operate time Release time Response frequency Output ON voltage drop Leakage current Insulation resistance Dielectric strength Vibration resistance Shock resistance Ambient temperature Certified standards G3R-OA202SZN-UTU G3R-OA202SLN-UTU G3R-ODX02SN-UTU 1 ms max. G3R-OD201SN-UTU 1/2 of load power source 1 ms max. 1/2 of load power source cycle + 1 ms max. between input and output 4, 000 VAC, 50/60 Hz for 1 min between input and output Destruction: 10 to 55 to 10 Hz, 0. 75-mm single amplitude Destruction: 1, 000 m/s2 Operating: 30°C to 80°C (with no icing) Storage: 30°C to 100°C (with no icing) UL508 File No. R9650094 (EN60950) Operating: 45% to 85% Approx. 18 g
Ambient humidity Weight
J-70
Solid State Relays G3R-I/O
Engineering Data
Load Current vs. Ambient Temperature
G3R-OA202SZN-UTU/OA202SLN-UTU G3R-ODX02SN-UTU (4 to 60 VDC) G3R-OD201SN-UTU (40 to 200 VAC)
2
4-point mounting (see note 1)
2
4-point mounting (see note 1)
2
Load current (A)
Load current (A)
1. 5 1. 4 1 0. 7 0. 5
16-point mounting (see note 2) Single-point mounting
Load current (A)
1. 5 1. 4 1
16-point mounting (see note 2) Single-point mounting
1. 5 1. 1 1
4-point mounting (see note 1)
16-point mounting (see note 2) 0. 6 0. 5
Single-point mounting
0. 5
-30 -20
0
20 30 40 55 60
80
100
-30 -20
0
20
40 55 60
80
100
-30 -20
0
20
40 55 60
80
100
Ambient temperature (°C)
Ambient temperature (°C)
Ambient temperature (°C)
Note: 1. When G70A-Z0C16 is mounted.
One Cycle Surge Current: Non-repetitive
Note: Keep the inrush current to half the rated value if it occurs repetitively.
G3R-OA202SZN-UTU/OA202SLN-UTU
G3R-ODX02SN-UTU
10 9 10 9 8
G3R-OD201SN-UTU
30
8
Inrush current (A)
Inrush current (A)
7 6 5 4 3 2 1
Inrush current (A)
10 30 50 100 300 500 1000 2000
7 6 5 4 3 2 1 0 10 30 50 100 300 500 1000 2000
20
10
10
30 50
100 200
500 1000
5000
0
Energized time (ms)
Energized time (ms)
Energized time (ms)
Solid State Relays
G3R-I/O
J-71
SSR
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G3R
1 3 0. 5
29 max.
5. 2
Terminal Arrangement/ Internal Connections (Bottom View) (+)
3
4 9. 6 17. 4
(-)
4. 75 1 5
4
Load
13 max. 4 10
28 max.
5 0. 5 4. 75
7. 5
4. 7
Input
1 5
(-)
2 20
(+)
Connecting Sockets
Connecting Socket Attaching Plates
P2RF-05
Five, M3. 5×8
4 dia. P2RF-05 Socket 58. 5 * M3 (M3 x16) or 3. 2-dia. [. . . ] (See note. ) Rated voltage Model G70A-ZOC16-3 G70A-ZOC16-4 G70A-ZIM16-5
Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.
Dimensions
Note: All units are in millimeters unless otherwise indicated.
G70A-ZOC16 (Output)
234 64
75
+0. 2 35. 3-0
28. 6
13. 5
M3. 5
9. 2 18. 4 48. 7
20. 7 34. 2
G70A-ZIM16 (Input)
234 48. 7
10. 2
+0. 2 35. 3-0
75
13. 5
M3. 5
9. 2 19. 6 64
20. 7 34. 2
J-74
Solid State Relays G3R-I/O
Terminal Arrangement/Internal Connection
G70A-ZOC16-3 (NPN)
- +
- + (+) (-)
Connector Terminal Arrangement (Top View)
G70A-ZOC16-4 (PNP)
(+) (-)
Connector Terminal Arrangement (Top View)
Solid State Relays
G3R-I/O
J-75
SSR
- +
- +
G70A-ZIM16-5 (NPN/PNP)
- +
1A1
2A1 1A2 2A2
3A1
4A1 3A2
5A1 4A2
6A1 5A2
7A1 6A2
8A1 7A2
9A1 8A2
10A1 9A2
11A1 10A2
12A1 11A2
13A1 12A2
14A1 13A2
15A1 14A2
16A1 15A2 16A2
- +
COM.
Connector Terminal Arrangement (Top View)
Safety Precautions
Precautions for Correct Use
Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance.
Protective Element
Since the SSR does not incorporate an overvoltage absorption component, be sure to connect an overvoltage absorption component when using the SSR under an inductive load.
Connection
With the SSR for DC switching, the load can be connected to either positive or negative output terminal of the SSR.
Precaution of Mounting Output Modules
With up to four G3R SSRs mounted closely and side by side, 2-A loads can be switched. With a G3R SSRs mounted every other slot, 2-A loads can be switched.
G3R
G3R
G3R
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0. 03937. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G3R-I-O
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.