Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON G7Z. We hope that this OMRON G7Z user guide will be useful to you.
Lastmanuals help download the user guide OMRON G7Z.
Detailed instructions for use are in the User's Guide.
[. . . ] Contact Mechanism of Auxiliary Contacts Z: Bifurcated crossbar contact
Auxiliary Contact Block
G73Z-Contact Configuration of Auxiliary Contacts 20: DPST-NO 11: SPST-NO/SPST-NC 02: DPST-NC 2. Contact Mechanism of Auxiliary Contacts Z: Bifurcated crossbar contact
Configuration
Structure Classification Relay with Auxiliary Contact Block 4 poles + 2 poles Contact configuration Relay 4PST-NO Auxiliary Contact Block DPST-NO SPST-NO/SPST-NC DPST-NC 3PST-NO/SPST-NC DPST-NO SPST-NO/SPST-NC DPST-NC DPST-NO/DPST-NC DPST-NO SPST-NO/SPST-NC DPST-NC Auxiliary Contact Block 2 poles --DPST-NO SPST-NO/SPST-NC DPST-NC G7Z-4A-20Z G7Z-4A-11Z G7Z-4A-02Z G7Z-3A1B-20Z G7Z-3A1B-11Z G7Z-3A1B-02Z G7Z-2A2B-20Z G7Z-2A2B-11Z G7Z-2A2B-02Z G73Z-20Z G73Z-11Z G73Z-02Z Screw terminals
Note: 1. Relay contact terminals are M5, and the coil terminals are M3. 5. [. . . ] The electrical endurance was measured at an ambient temperature of 23°C. The specifications for the auxiliary contact block mounted on the G7Z are the same as those for the G73Z auxiliary contact block.
Approved Standards
UL Standard: UL508, UL840 (File No. E41643)
Model Coil ratings 12, 24 VDC NO contact Contact ratings Number of test operations 80, 000 100, 000 100, 000
EN Standard/TÜV Certification: EN 60947-4-1 (Certification No. R50079155)
Model G7Z Coil ratings 12, 24 VDC Contact ratings NO contact AC-1: 40 A, 440 V, 50/60 Hz AC-3: 16 A, 440 V, 50/60 Hz DC-1: 5 A, 110 V *AC15: 0. 5 A, 440 V, 50/60 Hz *DC13: 0. 5 A, 110 V NC contact AC-1: 25 A, 440 V, 50/60 Hz DC-1: 5 A, 110 V *AC15: 0. 5 A, 440 V, 50/60 Hz *DC13: 0. 5 A, 110 V G73Z --NO contact AC15: 0. 5 A, 440 V , 50/60 Hz NC contact DC13: 0. 5 A, 110 V
G7Z
40 A, 480 VAC, 60 Hz (Resistive) 5 A, 120 VDC (Resistive) 22 A, 480 VAC, 60 Hz (General Use)
D300* (1-A current applied) --NC contact 25 A, 480 VAC, 60 Hz (Resistive) 5 A, 120 VDC (Resistive) 10 A, 480 VAC, 60 Hz (General Use) 100, 000
Note: Auxiliary contact ratings Reference Information UL 508: UL 840: Industrial control devices Insulation coordination including clearance and creepage distance for electrical devices Industrial control devices Contactors
D300* (1-A current applied) ---
Note: Auxiliary contact ratings
Model G73Z NO contact NC contact Contact ratings D300 (1-A current applied)
CSA C22. 2 No. 14: EN 60947-4-1:
CSA Standard: CSA Certification by : CSA C22. 2 No. 14
6
Power Relays G7Z
Connections
Terminal Arrangement/Internal Connections
Relay with Auxiliary Contact Block
G7Z-4A-20Z
53 A1 1 54 63 3 5 64 7
G7Z-4A-11Z
53 A1 1 54 61 3 5 62 7
G7Z-4A-02Z
51 A1 1 52 61 3 5 62 7
A2 2
4
6
8
A2 2
4
6
8
A2 2
4
6
8
Note: The coil has no polarity. G7Z-3A1B-20Z
53 A1 1 54 63 3 5 64 21
Note: The coil has no polarity. G7Z-3A1B-11Z
Note: The coil has no polarity. G7Z-3A1B-02Z
53 A1 1
54 61 3 5
62 21
51 A1 1
52 61 3 5
62 21
A2 2
4
6
22
A2 2
4
6
22
A2 2
4
6
22
Note: The coil has no polarity. G7Z-2A2B-20Z
Note: The coil has no polarity. G7Z-2A2B-11Z
Note: The coil has no polarity. · Mount the Relay sideways when it is mounted on a rail.
Power Relays
G7Z
9
Connecting
· Use round or open-end (Y-type) crimp terminals and connect the terminals with the appropriate tightening torque. Refer to the terminal section space in the following figure for the crimp terminal dimensions.
Operating Coil
(Internal Connections of Coils)
DC Coil
A2 A1
Relay Contacts (Unit: mm)
14. 5 12. 5
11 6 6 M5
· If a transistor drives the G7Z, check the leakage current and connect a bleeder resistor if necessary. · The must operate voltage is the minimum value for the Relay armature to operate and the contacts to turn ON. Therefore, fundamentally apply the rated voltage to the coils, taking into consideration the increases in coil resistance caused by voltage fluctuation and coil temperature rise.
Mirror Contact Mechanism
By combining a Relay with an auxiliary contact block, all NC contacts of the auxiliary contact block will satisfy an impulse withstand voltage of more than 2. 5 kV or maintain a gap of more than 0. 5 mm when the coil is de-energized even if at least one NO contact (main contact) of the Relay is welded (according to EN 60947-4-1).
Relay Coil
6. 8 4. 3
Description of Mirror Contact Mechanism
M3. 5
Auxiliary Contact Block
9. 5 6. 8 5. 5 5. 5 M3. 5
Impulse withstand voltage: 2. 5 kV min. or contact separation (a + b): 0. 5 mm min.
a b Auxiliary contact block
Relay NC NC
· One crimp terminal can be used for the Relay contact section (M5 screw). Two crimp terminals can be connected for the coil terminal and auxiliary contact block.
NO
NO
NO
NO
Recommended Crimp Terminals and Wire
Location Contact section Coil section Crimp terminals 5. 5-5 8-5 1. 25-3. 5 Appropriate wire size 2. 63 to 6. 64 mm2 (AWG12, 10) 6. 64 to 10. 52 mm2 (AWG8) 0. 5 to 1. 65 mm2 (AWG20 to 16)
Contact welding
· Use the following tightening torque when tightening screws. Loose screws may result in fire caused by abnormal heat generated when the power is being supplied. M5 screws: 2. 0 to 2. 2 N·m M3. 5 screws: 0. 8 to 0. 9 N·m · Allow suitable slack on leads when wiring, and do not subject the terminals to excessive force.
Microloads
The G7Z is used for switching power loads, such as current carry for device power supplies and heater loads. Use an auxiliary contact block (G73Z) if microloads are required for signal applications and operation status feedback.
10
Power Relays G7Z
Power Relays
G7Z
11
Warranty and Application Considerations
Read and Understand this Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. [. . . ] Consult with your OMRON representative at any time to confirm actual specifications of purchased product. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0. 03937. To convert grams into ounces, multiply by 0. 03527.
Cat. J160-E1-01
In the interest of product improvement, specifications are subject to change without notice.
Regional Headquarters OMRON EUROPE B. V. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G7Z
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON G7Z will begin.