User manual OMRON G9SX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON G9SX. We hope that this OMRON G9SX user guide will be useful to you.

Lastmanuals help download the user guide OMRON G9SX.


Mode d'emploi OMRON G9SX
Download

You may also download the following manuals related to this product:

   OMRON G9SX BROCHURE (1663 ko)

Manual abstract: user guide OMRON G9SX

Detailed instructions for use are in the User's Guide.

[. . . ] Flexible Safety Unit G9SX Logical AND Function Adds Flexibility to I/O Expansion · Facilitates partial or complete control system setup. · Solid-state outputs (excluding Expansion Units). · Detailed LED indications enable easy diagnosis. · TÜV Product Service certification for compliance with IEC/EN61508 (SIL3) and EN954-1 (Cat. [. . . ] Lights up while a HIGH state signal is input to T41. Blinks when an error relating to logical AND connection input occurs. Lights up while a HIGH state signal is input to T51. Blinks when an error relating to logical AND connection input occurs. Lights up while the Instantaneous safety outputs (S14, S24, S34) are in the ONstate. Blinks when an error relating to the instantaneous safety output occurs. Lights up while OFF-delayed safety outputs (S44, S54) are in the ON-state. Blinks when an error relating to OFF-delayed safety output occurs. Lights up or blinks when an error occurs. T2 Orange Safety input #2 indicator --- --- FB Orange Feedback/ reset input indicator --- --- AND Orange Logical AND input indicator --- --- --- --- AND1 Orange Logical AND --input indicator --- --- --- AND2 Orange Logical AND --input indicator --- --- --- EI Orange Safety output indicator --- ED Orange OFF-delayed safety output indicator --- --- ERR Red Error indicator Note: Refer to Fault Detection on the next page for details. Settings Indication (at Power ON) Settings for the G9SX can be checked by the orange indicators for approx. During this settings indication period, the ERR indicator will light, however the auxiliary error output will remain OFF Indicator T1 FB AND (AND1, AND2) Item Cross fault detection mode Reset mode Logical AND connection input mode Setting position Y1 terminal T32 or T33 terminal Logical AND connection preset switch Indicator status Lit Not lit Lit Not lit Lit Not lit Setting mode Detection mode Non-detection mode Manual reset mode Auto reset mode Enable logical AND input Disable logical AND input Setting status Y1 = open Y1 = 24 VDC T33 = 24 VDC T32 = 24 VDC "AND" "OFF" 14 Flexible Safety Unit G9SX Fault Detection When the G9SX detects a fault, the ERR indicator and/or other indicators light up or blink to inform the user about the fault. Check and take necessary measures referring to the following table, and then re-supply power to the G9SX. (Advanced Unit/Basic Unit) ERR Other indicator indicator --Blinks Fault Expected causes of the fault Check points and measures to take 1) Excessive electro-magnetic disturbance 1) Check the disturbance level around the G9SX Fault due to electroand the related system. magnetic disturbance or of 2) Failure of the internal circuit internal circuits. Fault involved with safety input 1 1) Check the wiring to T11 and T12. 1) Failure involving the wiring of safety input 1 2) Check the wiring to Y1. 2) Incorrect setting of cross fault detection 3) Replace with a new product. input 3) Failure of the circuit of safety input 1 1) Check the wiring to T21 and T22. 1) Failure involving the wiring of safety input 2 2) Check the wiring to Y1. 2) Incorrect setting of cross fault detection 3) Replace with a new product. input 3) Failure of circuits of safety input 2 1) Failures involving the wiring of feedback/ 1) Check the wiring to T31, T32 and T33. 2) Failures of the circuit of feedback/reset input 1) Improper feedback signals from Expansion Unit 2) Abnormal supply voltage to Expansion Unit 3) Failure of the circuit of safety relay contact outputs 1) Failure involving the wiring of instantaneous safety outputs 2) Failure of the circuit of Instantaneous safety outputs 3) Failure involving the wiring of the logical connection output 4) Failure of the circuit of the logical connection output 5) Failure involving the wiring of the auxiliary monitor output 6) Impermissible high ambient temperature 1) Failure involving the wiring of OFFdelayed safety relay contact outputs 2) Incorrect set values for OFF-delay time 3) Failure of the circuit of OFF-delayed safety relay contact outputs 4) Impermissible high ambient temperature 1) Check the connecting cable of Expansion Unit and the connection of the termination socket. 2) Check the supply voltage to Expansion Unit. Note: Make sure that all Expansion units' PWR indicators are lit. [. . . ] contacts of contactors KM1, KM2, KM3, KM4, KM5, and KM6 in series. Flexible Safety Unit G9SX 23 G9SX-BC202 (24 VDC) (2-channel Emergency Stop Switch Input/Manual Reset) + G9SX-AD322-T15 (24 VDC) (2-channel Safety Limit Switch Input/Auto Reset) + G9SX-AD322-T15 (24 VDC) (2-channel Safety Limit Switch Input/Auto Reset) + G9SX-ADA222-T150 (24 VDC) (2-channel Safety Limit Switch Input/Auto Reset) + Feedback Loop 11 12 S1 KM 1 S2 +24 V NC KM2 21 22 KM1 KM2 A1 T11 T12 T21 T22 T31 T32 T33 Y1 M1 G9SX-BC202 (Unit A) +24 V S1: Emergency stop switch S2: Reset switch S3, S5, S7: Safety limit switch S4, S6, S8: Limit switch KM1 to KM8: Contactor M1 to M4: 3-phase motor Control circuit A2 S14 S24 KM1 KM2 L1 L2 X1 X2 PLC etc. GND 23 S4 24 S6 23 Feedback Loop 11 S3 12 24 Feedback Loop 11 S5 12 Guard 1 Guard 2 KM3 KM4 KM3 KM5 KM6 KM5 KM 4 KM 6 open +24 V +24 V NC AND M2 open +24 V +24 V NC AND M3 A1 T11 T12 T21 T22 T31 T32 T33 Y1 T41 T42 A1 T11 T12 T21 T22 T31 T32 T33 Y1 OFF T41 T42 OFF G9SX-AD322-T15 (Unit B) Control circuit G9SX-AD322-T15 (Unit C) Control circuit A2 S14 S24 S34 S44 S54 L1 X1 X2 KM3 KM4 PLC etc. A2 S14 S24 S34 S44 S54 L1 X1 X2 KM5 KM6 PLC etc. GND GND 23 S8 24 Feedback Loop 11 S7 12 Guard 3 KM7 KM8 open +24 V +24 V NC AND T41 T51 T41 T42 T51 T52 OFF Motor controller KM7 A1 T11 T12 T21 T22 T31 T32 T33 Y1 S14 4 G9SX-ADA222-T150 (Unit D) Control circuit KM8 M4 A2 S14 S24 S44 S54 L1 L2 X1 X2 KM7 KM8 PLC etc. GND Motor controller (Operation command) Note: This example corresponds to category 4. 24 Flexible Safety Unit G9SX Timing chart G9SX-BC202 (Unit A) Emergency stop switch S1 Reset switch S2 KM1, KM2, N. C. contact Logical AND output L1, L2 (3) G9SX-AD322-T15 (Unit B) Logical AND input T41 Safety limit switch S3 Limit switch S4 KM3, KM4, N. C. contact Logical AND output L1 (1) G9SX-AD322-T15 (Unit C) Logical AND input T41 Safety limit switch S5 Limit switch S6 KM5, KM6, N. C. contact Logical AND output L1 G9SX-ADA222-T150 (Unit D) Logical AND input T41 Logical AND input T51 Safety limit switch S7 Limit switch S8 KM7, KM8, N. C. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON G9SX

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON G9SX will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag