User manual OMRON H2C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON H2C. We hope that this OMRON H2C user guide will be useful to you.

Lastmanuals help download the user guide OMRON H2C.


Mode d'emploi OMRON H2C
Download
Manual abstract: user guide OMRON H2C

Detailed instructions for use are in the User's Guide.

[. . . ] Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 or P3GA-11 Socket. Hold-down Clips are sold in sets of two. Specifications Time Ranges Five time ranges are available for each timer by turning the time range selector every 60 degrees. Note: Rated time is displayed on the window. Time range code Position of time range selector A B C 1. 25 to 30 s 0. 2 to 6 s 0. 5 to 12 s 7. 5 s to 3 min 2 to 60 s 5 to 120 s 1. 25 to 30 min 0. 2 to 6 min 0. 5 to 12 min 7. 5 min to 3 h 2 to 60 min 5 to 120 min 1. 25 to 30 h 0. 2 to 6 h 0. 5 to 12 h Ratings Item Rated supply voltage (motor and clutch) Operating voltage range Power consumption Reset voltage Reset time Control outputs Mounting method H2C 24, 48, 100, 110, 115, 120, 200, 220, or 240 VAC (50/60 Hz) (see note) 85% to 110% of rated supply voltage 4. 2 VA max. [. . . ] For a load current of 3 A max. , dimension L becomes 15 mm min. with an interval of 5 mm between timers. For a load current of 6 A max. , dimension L becomes 20 mm min. with an interval of 10 mm between timers. Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ Dimensions with Back Connecting Socket P3G-08/P3GA-11 81. 5 80 H2C H2C-S H2C-R H2C-SR + Adapter 92. 2 85. 7 16. 3 H2C H2C-S H2C-R H2C-SR 16. 3 100. 8* 103. 1* H2C-8 H2C-8R H2C-8 H2C-8R + Adapter Y92F-30 P2CF-11 P2CF-11-E P2CF-08 P2CF-08-E P3GA-11 (When Y92A-48G mounted) Y92F-30 P3G-08 (When Y92A-48G mounted) *These dimensions vary with the kind of DIN track (reference value). 6 Motor Timer H2C Accessories (Order Separately) Adapter for Flush Mounting Y92F-30 Track Mounting/Front Connecting Socket P2CF-08 Eight, M3. 5 x 7. 5 sems 7. 8 3 4. 5 70 max. 20. 3 max. 35. 4 Terminal Arrangement/ Internal Connections (Top View) Surface Mounting Holes Two, 4. 5 dia. or two, M4 P2CF-08-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eight, M3. 5 x 7. 5 sems 7. 8 5 3 70 max. 35. 4 4. 5 40±0. 2 Motor Timer H2C 7 Track Mounting/Front Connecting Socket P2CF-11 Eleven, M3. 5 x 7. 5 sems 7. 8 3 4. 5 70 max. 31. 2 max. 35. 4 Terminal Arrangement/ Internal Connections (Top View) Surface Mounting Holes Two, 4. 5 dia. or two, M4 40±0. 2 P2CF-11-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eleven, M3. 5 x 7. 5 sems 7. 8 3 1. 2 70 max. 35. 4 5 4. 5 Back Connecting Socket P3G-08 27 dia. Terminal Arrangement/ Internal Connections (Bottom View) 45 45 4. 9 17 P3GA-11 27 dia. Terminal Arrangement/ Internal Connections (Bottom View) 25. 6 45 45 4. 5 16. 3 6. 2 Finger Safe Terminal Cover Conforming to VDE0106/P100 Y92A-48G (Attachment for P3G-08/ P3GA-11 Socket) 34 Twelve, 6. 4 dia. holes 47. 7 x 47. 7 48 x 48 16. 5 24. 6 27. 6 47. 4 8 Motor Timer H2C Mounting Track PFP-100N, PFP-50N PFP-100N2 16 7. 3±0. 15 4. 5 35±0. 3 15 25 10 25 1, 000 (500) (see note) 25 10 25 15 (5) (see note) 27±0. 15 15 1 25 10 25 1, 000 25 10 25 15 4. 5 35±0. 3 27 24 1 29. 2 1. 5 Note: The value shown in parentheses are for the PFP-50N. End Plate PFP-M 10 6. 2 1. 8 Spacer PFP-S 5 16 12 1 50 1. 8 35. 5 35. 3 44. 3 34. 8 11. 5 10 M4 x 8 pan head screw 1. 3 4. 8 16. 5 Time Setting Ring Y92A-Y1 The time setting ring locks the time setting knob to store the set time to facilitate its resetting. A maximum of two time setting rings are connectable per timer. Protective Cover Y92A-48B The protective cover shields the front panel, particularly the time setting section, from dust, dirt, and water, as well as prevents the set value from being altered due to accidental contact with the time setting knob. Timer Hold-down Clips Y92H-2 (for PF085A/PF113A Connecting Socket) Y92H-1 (for PL08/PL11 Connecting Socket) Motor Timer H2C 9 Safety Precautions !CAUTION This may occasionally cause electric shock, fire, or malfunction. Never disassemble, repair, or modify the H2C. This may occasionally cause electric shock, fire, or malfunction. Do not allow metal fragments or lead wire scraps to fall inside the H2C. Precautions for Correct Use How to Change the Time Range Change the time range by turning the knob clockwise using a flatblade screwdriver or an Allen wrench. The selected time is displayed in the time range display window above the knob. Precautions for Safe Use Observe the following items to ensure the safe use of this product. Environmental Precautions · Store the H2C within the specified ratings. If the H2C has been stored at temperatures ­10°C or lower, let it stand for 3 hours or longer at room temperature before turning ON the power supply. · Use the H2C within the specified ratings for operating temperature and humidity. Therefore, use the H2C in combination with relays and avoid leaving the H2C for more than 1 month with an output turned ON. How to Mount the Timer on Mounting Track Mounting First hook portion A of the timer to the mounting track, then press the timer in direction B. Dismounting Pull out portion C with a round-blade screwdriver and remove the timer from the mounting track. A C B Electrical Set The motor and clutch do not need to be reset simultaneously. Use the voltage applied to the clutch for resetting with the H2C-@R. Do not allow power to be continuously applied to the motor and clutch for extended periods of time. X2/b T/a X1/a X1/a T X1 X2 X Auxiliary relay (e. g. , MY Relay) 10 Motor Timer H2C Others Do not turn the operation time setting knob beyond the range of the scale. To achieve higher accuracy in setting, measure the operation time while turning the operation time setting knob. [. . . ] IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. Take all necessary steps to determine the suitability of the product for the systems, machines, and equipment with which it will be used. Know and observe all prohibitions of use applicable to this product. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H2C

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H2C will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag