User manual OMRON H3CR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!

If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON H3CR. We hope that this OMRON H3CR user guide will be useful to you.

Lastmanuals help download the user guide OMRON H3CR.


Mode d'emploi OMRON H3CR
Download
Manual abstract: user guide OMRON H3CR

Detailed instructions for use are in the User's Guide.

[. . . ] Solid-state Timer H3CR Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 52), and Safety Precautions (page 22, 44, 51). DIN 48 × 48-mm Multifunctional Timer Series · Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives. · Six-language instruction manual provided. Broad Line-up of H3CR Series H3CR H3CR-A H3CR-F H3CR-G H3CR-H Multifunctional Timer H3CR-A H3CR-AS H3CR-AP H3CR-A8 H3CR-A8S H3CR-A8E 11-pin model 8-pin model 8-pin with instantaneous contact output model Twin Timer Star-delta Timer Power OFF-delay Timer H3CR-HRL 11-pin model H3CR-H8L 8-pin model H3CR-H8RL H3CR-F H3CR-G8L 8-pin model H3CR-FN 11-pin model H3CR-G8EL H3CR-F-300 H3CR-FN-300 H3CR-F8 H3CR-F8N 8-pin model H3CR-F8-300 H3CR-F8N-300 Note: H3CR-AS, H3CR-A8S: Transistor output models Contents Solid-state Timer H3CR-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (5 A at 250 VAC, resistive load at 1, 800 operations/h) (See note) (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0. 15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Case color Degree of protection Weight Light Gray (Munsell 5Y7/1) IP40 (panel surface) Approx. 100 g Note: Refer to the Life-test Curve. 26 Solid-state Twin Timers H3CR-F Life-test Curve 10, 000 Switching operations (x 103) 5, 000 1, 000 500 30 VDC L/R = 7 ms 250 VAC/30 VDC (cos = 1) Reference: A maximum current of 0. 15 A can be switched at 125 VDC (cos = 1) and a maximum current of 0. 1 A can be switched if L/R is 7 ms. In both cases, a life of 100, 000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P). 100 250 VAC (cos = 0. 4) Load current (A) Connections Block Diagrams ON indicator OFF indicator Zero setting detection circuit Indicator circuit ROM RAM Clock Output circuit AC (DC) input Power supply circuit One-chip microcomputer Time range/unit selectors I/O Functions Inputs Outputs Control output --Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob. Terminal Arrangement H3CR-F8 H3CR-F8 NH3CR-F8-300 H3CR-F8N-300 H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 (+)(~) Power supply Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals. Solid-state Twin Timers H3CR-F 27 Operation Timing Chart tON: ON set time tOFF: OFF set time Operating mode Flicker OFF start Power ON OFF Timing chart 0. 1 s min. tOFF tON tOFF tON tOFF tOFF Lit ON indicator Not lit OFF Lit indicator Not lit Output NO ON OFF ON OFF 0. 1 s min. Output NC Flicker ON start Power ON OFF tON tOFF tON tOFF tON tOFF Lit ON indicator Not lit Lit OFF indicator Not lit Output NO ON OFF ON OFF Output NC Note: 1. The reset time requires a minimum of 0. 1 s. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer. Nomenclature OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. OFF-time unit display window OFF-time unit selector (select one from sec. 10 s, min. , and hrs, or from 10 s, 10 min, hrs, and 10 h) Scale range display windows ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting Time range selector (select one from 1. 2, 3, 12, and 30 at full scale) For both ON-time and OFF-time. ON-time unit display window ON-time unit selector (select one from sec, 10 s, min, and hrs, or from 10 s, 10 min, hrs, and 10 h) 28 Solid-state Twin Timers H3CR-F Dimensions Note: All units are in millimeters unless otherwise indicated. H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300 48 48 17. 4 5. 7 6 66. 6 52. 3 0. 7 37 dia. 14 dia. 44. 8 × 44. 8 R1. 3 11 pins H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300 48 48 17. 4 5. 7 6 66. 6 52. 3 0. 7 37 dia. 14 dia. 44. 8 × 44. 8 R1. 3 8 pins Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@ Dimensions with Back Connecting Socket P3G-08/P3GA-11 17. 4 81. 5 80 81. 5 75 17. 4 H3CR-F H3CR-FN 103. 2* 100. 9 92. 3* H3CR-F8 H3CR-F8N 90. 0 H3CR-F H3CR-FN H3CR-F8 H3CR-F8N Y92F-30 P2CF-11 P2CF-11-E 2. 3* P2CF-08 P2CF-08-E 2. 3* P3GA-11 (When Y92A-48G mounted) Y92F-30 P3G-08 (When Y92A-48G mounted) *These dimensions vary with the kind of DIN track (reference value). Solid-state Twin Timers H3CR-F 29 Solid-state Star-delta Timer H3CR-G DIN 48 × 48-mm Star-delta Timer · A wide star-time range (up to 120 seconds) and star-delta transfer time range (up to 0. 5 seconds). Model Number Structure Model Number Legend H3CR - G 8 @ L @ 12345 1. Outputs None: Star-delta operation contact E: Star-delta operation contact and instantaneous contact 4. Supply Voltage 100-120AC: 100 to 120 VAC 200-240AC: 200 to 240 VAC Ordering Information List of Models Outputs Time-limit contact Time-limit contact and instantaneous contact Supply voltage 100 to 120 VAC 200 to 240 VAC 100 to 120 VAC 200 to 240 VAC Note: Specify both the model number and supply voltage when ordering. Example: H3CR-G8L 100-120AC Supply voltage H3CR-G8L 100-120AC H3CR-G8L 200-240AC H3CR-G8EL 100-120AC H3CR-G8EL 200-240AC 8-pin models 30 Solid-state Star-delta Timer H3CR-G Accessories (Order Separately) Name/specifications Flush Mounting Adapter Y92F-30 Y92F-70 Y92F-71 Mounting Track 50 cm (l) × 7. 3 mm (t) 1 m (l) × 7. 3 mm (t) 1 m (l) × 16 mm (t) End Plate Spacer Protective Cover Track Mounting/ Front Connecting Socket Back Connecting Socket Time Setting Ring Panel Cover (See note 2) 8-pin 8-pin, finger safe type 8-pin 8-pin, finger safe type Setting a specific time Limiting the setting range Light gray (5Y7/1) Black (N1. 5) Medium gray (5Y5/1) Hold-down Clip (See note 3) For PL08 and PL11 Sockets For PF085A Socket PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P3G-08 P3G-08 with Y92A-48G (See note 1) Y92S-27 Y92S-28 Y92P-48GL Y92P-48GB Y92P-48GM Y92H-1 Y92H-2 Models Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket. The Time Setting Ring and Panel Cover are sold together. Hold-down Clips are sold in sets of two. Specifications General Item Functions Pin type Operating/Reset method Output type Star-delta timer 8-pin Time-limit operation/Self-reset Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Instantaneous: SPST-NO H3CR-G8L H3CR-G8EL Star-delta timer with instantaneous output Mounting method Approved standards DIN track mounting, surface mounting, and flush mounting UL508, CSA C22. 2 No. 14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1. Time Ranges Time unit Full scale setting 6 12 60 120 Star-delta transfer time 0. 5 to 6 s 1 to 12 s 5 to 60 s 10 to 120 s Programmable at 0. 05 s, 0. 1 s, 0. 25 s or 0. 5 s Star operation time ranges Solid-state Star-delta Timer H3CR-G 31 Ratings Rated supply voltage (See notes 1 and 2. ) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz) Operating voltage range Power reset Power consumption Control outputs 85% to 110% of rated supply voltage Minimum power-opening time: 0. 5 s 100 to 120 VAC: approx. 6 VA (2. 6 W) at 120 VAC 200 to 240 VAC: approx. 12 VA (3. 0 W) at 240 VAC Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos = 1) Note: 1. [. . . ] Doing so may result in damage to contacts. Others If the Timer is mounted to a control board, dismount the Timer from the control board or short-circuit the control board circuitry before carrying out a voltage withstand test between the electric circuitry and non-charged metal part of the Timer. This protects the internal circuitry of the Timer from damage. Power Supplies A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. An AC power supply can be connected to the power input terminals without regard to polarity. A DC power supply must be connected to the power input terminals as designated according to the polarity of the terminals. [. . . ]

DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H3CR

Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets...
In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.

Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H3CR will begin.

Search for a user manual

 

Copyright © 2015 - LastManuals - All Rights Reserved.
Designated trademarks and brands are the property of their respective owners.

flag