[. . . ] Solid-state Timer
H3CR
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty and Application Considerations (page 52), and Safety Precautions (page 22, 44, 51).
DIN 48 × 48-mm Multifunctional Timer Series
· Conforms to EN61812-1 and IEC60664-1 4 kV/2 for Low Voltage, and EMC Directives. · Six-language instruction manual provided.
Broad Line-up of H3CR Series
H3CR
H3CR-A
H3CR-F
H3CR-G
H3CR-H
Multifunctional Timer H3CR-A H3CR-AS H3CR-AP H3CR-A8 H3CR-A8S H3CR-A8E
11-pin model 8-pin model 8-pin with instantaneous contact output model
Twin Timer
Star-delta Timer
Power OFF-delay Timer H3CR-HRL 11-pin model H3CR-H8L 8-pin model H3CR-H8RL
H3CR-F H3CR-G8L 8-pin model H3CR-FN 11-pin model H3CR-G8EL H3CR-F-300 H3CR-FN-300 H3CR-F8 H3CR-F8N 8-pin model H3CR-F8-300 H3CR-F8N-300
Note: H3CR-AS, H3CR-A8S: Transistor output models
Contents
Solid-state Timer
H3CR-A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . [. . . ] (5 A at 250 VAC, resistive load at 1, 800 operations/h) (See note) (EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD: EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 IEC61000-4-2:
6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: IEC61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity RF-interference from Pulse-modulated Radio Waves: IEC61000-4-3: 10 V/m (900±5 MHz) (level 3) Immunity Conducted Disturbance: IEC61000-4-6: 10 V (0. 15 to 80 MHz) (level 3) Immunity Burst: IEC61000-4-4: 2 kV power-line (level 3) 2 kV I/O signal-line (level 4) Immunity Surge: IEC61000-4-5: 1 kV line to line (level 3) 2 kV line to ground (level 3) Case color Degree of protection Weight Light Gray (Munsell 5Y7/1) IP40 (panel surface) Approx. 100 g
Note: Refer to the Life-test Curve.
26
Solid-state Twin Timers H3CR-F
Life-test Curve
10, 000
Switching operations (x 103)
5, 000
1, 000 500 30 VDC L/R = 7 ms 250 VAC/30 VDC (cos = 1)
Reference: A maximum current of 0. 15 A can be switched at 125 VDC (cos = 1) and a maximum current of 0. 1 A can be switched if L/R is 7 ms. In both cases, a life of 100, 000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P).
100 250 VAC (cos = 0. 4)
Load current (A)
Connections
Block Diagrams
ON indicator OFF indicator Zero setting detection circuit
Indicator circuit ROM RAM Clock Output circuit
AC (DC) input
Power supply circuit
One-chip microcomputer
Time range/unit selectors
I/O Functions
Inputs Outputs Control output --Outputs are turned ON/OFF according to the time set by the ON- and OFF-time setting knob.
Terminal Arrangement
H3CR-F8 H3CR-F8 NH3CR-F8-300 H3CR-F8N-300 H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300
(+)(~)
Power supply
Power supply Note: Leave terminals 5, 6, and 7 open. Do not use them as relay terminals.
Solid-state Twin Timers
H3CR-F
27
Operation
Timing Chart
tON: ON set time tOFF: OFF set time Operating mode Flicker OFF start
Power ON OFF
Timing chart
0. 1 s min.
tOFF
tON
tOFF
tON
tOFF
tOFF
Lit ON indicator Not lit OFF Lit indicator Not lit Output NO
ON OFF ON OFF
0. 1 s min.
Output NC
Flicker ON start
Power ON OFF
tON
tOFF
tON
tOFF
tON
tOFF
Lit ON indicator Not lit Lit OFF indicator Not lit Output NO ON OFF ON OFF
Output NC
Note: 1. The reset time requires a minimum of 0. 1 s. When power is supplied in flicker ON start mode, the OFF indicator lights momentarily. This, however, has no effect on the performance of the Timer.
Nomenclature
OFF indicator (green) Lit when the output is OFF. ON indicator (orange) Lit when the output is ON. OFF-time unit display window OFF-time unit selector (select one from sec. 10 s, min. , and hrs, or from 10 s, 10 min, hrs, and 10 h)
Scale range display windows
ON-time setting knob (with orange pointer) For ON-time setting OFF-time setting knob (with green pointer) For OFF-time setting
Time range selector (select one from 1. 2, 3, 12, and 30 at full scale) For both ON-time and OFF-time.
ON-time unit display window ON-time unit selector (select one from sec, 10 s, min, and hrs, or from 10 s, 10 min, hrs, and 10 h)
28
Solid-state Twin Timers H3CR-F
Dimensions
Note: All units are in millimeters unless otherwise indicated.
H3CR-F H3CR-FN H3CR-F-300 H3CR-FN-300
48
48
17. 4 5. 7 6
66. 6 52. 3
0. 7
37 dia. 14 dia.
44. 8 × 44. 8
R1. 3 11 pins
H3CR-F8 H3CR-F8N H3CR-F8-300 H3CR-F8N-300
48
48
17. 4 5. 7 6
66. 6 52. 3
0. 7
37 dia. 14 dia.
44. 8 × 44. 8
R1. 3 8 pins
Dimensions with Front Connecting Socket P2CF-08-@/P2CF-11-@
Dimensions with Back Connecting Socket P3G-08/P3GA-11
17. 4 81. 5 80 81. 5 75
17. 4
H3CR-F H3CR-FN 103. 2* 100. 9 92. 3*
H3CR-F8 H3CR-F8N 90. 0
H3CR-F H3CR-FN
H3CR-F8 H3CR-F8N
Y92F-30 P2CF-11 P2CF-11-E
2. 3*
P2CF-08 P2CF-08-E
2. 3*
P3GA-11 (When Y92A-48G mounted)
Y92F-30
P3G-08 (When Y92A-48G mounted)
*These dimensions vary with the kind of DIN track (reference value).
Solid-state Twin Timers
H3CR-F
29
Solid-state Star-delta Timer
H3CR-G
DIN 48 × 48-mm Star-delta Timer
· A wide star-time range (up to 120 seconds) and star-delta transfer time range (up to 0. 5 seconds).
Model Number Structure
Model Number Legend
H3CR - G 8 @ L @
12345
1. Outputs None: Star-delta operation contact E: Star-delta operation contact and instantaneous contact 4. Supply Voltage 100-120AC: 100 to 120 VAC 200-240AC: 200 to 240 VAC
Ordering Information
List of Models
Outputs Time-limit contact Time-limit contact and instantaneous contact Supply voltage 100 to 120 VAC 200 to 240 VAC 100 to 120 VAC 200 to 240 VAC Note: Specify both the model number and supply voltage when ordering. Example: H3CR-G8L 100-120AC Supply voltage H3CR-G8L 100-120AC H3CR-G8L 200-240AC H3CR-G8EL 100-120AC H3CR-G8EL 200-240AC 8-pin models
30
Solid-state Star-delta Timer H3CR-G
Accessories (Order Separately)
Name/specifications Flush Mounting Adapter Y92F-30 Y92F-70 Y92F-71 Mounting Track 50 cm (l) × 7. 3 mm (t) 1 m (l) × 7. 3 mm (t) 1 m (l) × 16 mm (t) End Plate Spacer Protective Cover Track Mounting/ Front Connecting Socket Back Connecting Socket Time Setting Ring Panel Cover (See note 2) 8-pin 8-pin, finger safe type 8-pin 8-pin, finger safe type Setting a specific time Limiting the setting range Light gray (5Y7/1) Black (N1. 5) Medium gray (5Y5/1) Hold-down Clip (See note 3) For PL08 and PL11 Sockets For PF085A Socket PFP-50N PFP-100N PFP-100N2 PFP-M PFP-S Y92A-48B P2CF-08 P2CF-08-E P3G-08 P3G-08 with Y92A-48G (See note 1) Y92S-27 Y92S-28 Y92P-48GL Y92P-48GB Y92P-48GM Y92H-1 Y92H-2 Models
Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket. The Time Setting Ring and Panel Cover are sold together. Hold-down Clips are sold in sets of two.
Specifications
General
Item Functions Pin type Operating/Reset method Output type Star-delta timer 8-pin Time-limit operation/Self-reset Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Time-limit: SPST-NO (star operation circuit) SPST-NO (delta operation circuit) Instantaneous: SPST-NO H3CR-G8L H3CR-G8EL Star-delta timer with instantaneous output
Mounting method Approved standards
DIN track mounting, surface mounting, and flush mounting UL508, CSA C22. 2 No. 14, NK, Lloyds Conforms to EN61812-1 and IEC60664-1 (VDE0110) 4kV/2. Output category according to EN60947-5-1.
Time Ranges
Time unit Full scale setting 6 12 60 120 Star-delta transfer time 0. 5 to 6 s 1 to 12 s 5 to 60 s 10 to 120 s Programmable at 0. 05 s, 0. 1 s, 0. 25 s or 0. 5 s Star operation time ranges
Solid-state Star-delta Timer
H3CR-G
31
Ratings
Rated supply voltage (See notes 1 and 2. ) 100 to 120 VAC (50/60 Hz), 200 to 240 VAC (50/60 Hz) Operating voltage range Power reset Power consumption Control outputs 85% to 110% of rated supply voltage Minimum power-opening time: 0. 5 s 100 to 120 VAC: approx. 6 VA (2. 6 W) at 120 VAC 200 to 240 VAC: approx. 12 VA (3. 0 W) at 240 VAC Contact output: 5 A at 250 VAC/30 VDC, resistive load (cos = 1)
Note: 1. [. . . ] Doing so may result in damage to contacts.
Others
If the Timer is mounted to a control board, dismount the Timer from the control board or short-circuit the control board circuitry before carrying out a voltage withstand test between the electric circuitry and non-charged metal part of the Timer. This protects the internal circuitry of the Timer from damage.
Power Supplies
A DC power supply can be connected if its ripple factor is 20% or less and the mean voltage is within the rated operating voltage range of the Timer. An AC power supply can be connected to the power input terminals without regard to polarity. A DC power supply must be connected to the power input terminals as designated according to the polarity of the terminals. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H3CR
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.