Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... DON'T FORGET : ALWAYS READ THE USER GUIDE BEFORE BUYING !!!
If this document matches the user guide, instructions manual or user manual, feature sets, schematics you are looking for, download it now. Lastmanuals provides you a fast and easy access to the user manual OMRON H3JA. We hope that this OMRON H3JA user guide will be useful to you.
Lastmanuals help download the user guide OMRON H3JA.
Detailed instructions for use are in the User's Guide.
[. . . ] Solid-state Timer
Economical, Compact, Plug-in Timer
I Time limit operation with automatic resetting. I DIN size (36 x 36 mm), fits standard 8-pin sock-
H3JA
ets.
I Wide choice of supply voltages:
24, 100 to 120, 200 to 240 VAC, 24 VDC. [. . . ] 0. 9 W at 24 VDC
Rated supply voltage Operating voltage range Power consumption
Control outputs
H3JA-8A: 7 A at 250 VAC, resistive load H3JA-8C: 5 A at 250 VAC, resistive load
2
H3JA
I
H3JA
Characteristics
Accuracy of operating time Setting error Influence of voltage Influence of temperature Insulation resistance Dielectric strength
2% max. (at 500 VDC) 2, 000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts, and between contact-carrying and control circuit, and between contacts of different poles) 1, 000 VAC, 50/60 Hz for 1 min (between non-continuous contacts)
Impulse withstand voltage Noise immunity Static immunity Vibration resistance Shock resistance Ambient temperature Ambient humidity Life expectancy
1. 5 kV (between power terminals) and 1. 5 kV (between output terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 ms, 1-ns rise)
Destruction: 8 kV Malfunction: 6 kV Destruction: 10 to 55 Hz with 0. 75-mm double amplitude in 3 directions for 1 hour each. Malfunction: 10 to 55 Hz with 0. 5-mm double amplitude in 3 directions for 10 minutes each. Destruction: 1, 000 m/s2 Malfunction: 100 m/s2 Operating: Storage: Operating: H3JA-8A Mechanical: Electrical: H3JA-8C Mechanical: Electrical: 10C to 55C 25C to 65C 35% to 85% 10, 000, 000 operations min. (7 A resistive load at 250 VAC, 360 operations/h) 10, 000, 000 operations min. (5 A resistive load at 250 VAC, 360 operations/h) EN55011 Group 1 class A EN55011 Group 1 class A
3 kV (between power terminals) 4. 5 kV (between current-carrying terminal and exposed non-current-carrying metal parts)
EMC
(EMI) Emission Enclosure: Emission AC Mains: (EMS) Immunity ESD:
EN61000-4-2: 6 kV contact discharge (level 3) 8 kV air discharge (level 3) Immunity RF-interference from AM Radio Waves: EN61000-4-3: 10 V/m (80 MHz to 1 GHz) (level 3) Immunity Burst: EN61000-4-4: 2 kV power port and output port (level 3) 1 kV control port with capacitive clamp (level 3) Immunity Surge: EN61000-4-5: 2 kV common mode (level 3) 1 kV differential mode (level 3) Approved standard Case color Degree of protection Weight UL508, CSA C22. 2 No. 14, conforms to EN61812-1 Light gray (Munsell 5Y7/1) IP40 (panel surface) H3JA-8A: Approx. 60 g
3
H3JA
H3JA
Engineering Data
H3JA-8A Switching operations (x 10 3 ) H3JA-8C Switching operations (x 10 3 )
5, 000
30 VDC resistive load 1, 000 500 30 VDC inductive load L/R=7 ms 120 VAC resistive load
100 50
120 VAC inductive load cosB=0. 4
250 VAC resistive load
B
0
1
2
3
4
5
6
7
Load current (A)
Load current (A)
Operation
I
Timing Chart
100 ms min. Rt Terminals (2)-(7) (power) Set time Set time
H3JA-8A
(6)-(8) (NO)
(5)-(8) (NC)
Time UP indicator (Orange) Power ON indicator (Green)
H3JA-8C
Terminals (2)-(7) (power) Set time
100 ms min. Rt
Set time
(1)-(3) (NO) (6)-(8)
(1)-(4) (5)-(8) (NC)
Time UP indicator (Orange) Power ON indicator (Green)
4
H3JA
H3JA
Dimensions
Note: All units are in millimeters unless otherwise indicated.
7 36 LED 4 60 14. 2 0. 7
36
30. 5
32. 8
I
Accessories (Order Separately)
Flush Mounting Adapter Y92F-31
Adapter Y92F-31 shown with H3JA-8( and back connecting socket.
15. 5
Panel Cutout Recommended panel thickness: 1 to 5 mm
US08
46
40
44
13
37. 4 22 11 91. 3
US08 Connecting Socket
Track Mounting/Front Connecting Socket PF085A
Eight, M3. 5 ´ 7 sems
Terminal Arrangement (Top View)
Two, 4. 5 dia. [. . . ] To convert grams into ounces, multiply by 0. 03527.
Cat. L100-E1-1A
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company Measuring and Supervisory Controls Department Shiokoji Horikawa, Shimogyo-ku Kyoto, 600-8530 Japan Tel: (81)75-344-7108/Fax: (81)75-344-7189
Printed in Japan 0401-2M (1100) (A)
8 [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H3JA
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H3JA will begin.