Detailed instructions for use are in the User's Guide.
[. . . ] LED indication for power and output statuses. High repeat accuracy.
H3Y
RC Ordering Information
Operation/resetting Ope a o / ese g t system Time-limit operation/ e o ea o / self-resetting lf tti Time-limit contact e co ac Time ranges e a ges Supply voltage Supp y o age Model Surface /DIN-track mounting (with socket) DPDT 0 0. 1 s to 30 min o 110 VAC 220 VAC 24 VDC 4PDT 110 VAC 220 VAC 24 VDC Note: Specify the model number, supply voltage, and rated time when ordering. H3Y-2 110 VAC 1s Rated time Supply voltage H3Y-4 3 H3Y-2 3
Accessories
Track mounted socket (see note ) ac ou ed soc e oe Solder terminal PYF08A, PYF08A-N, PYF08A-E PYF14A, PYF14A-N, PYF14A-E Note: PY08 PY14 Back connecting socket Wire-wrap terminal PY08QN(2) PY14QN(2) PY08-02 PY14-02 PC terminal
Track mounted socket can be used as a front connecting socket.
Specifications
Time Ranges
Rated time Time setting range 1s 0. 1 to 1 s 5s 0. 2 to 5 s 10 s 0. 5 to 10 s 30 s 1. 0 to 30 s 60 s 2. 0 to 60 s 3 min 0. 1 to 3 min 30 min 1. 0 to 30 min
1
H3Y Ratings
Item Rated supply voltage Operating voltage range Power consumption 85% to 110% of rated supply voltage 100 VAC: Relay ON: Relay OFF: 200 VAC: Relay ON: Relay OFF: 24 VDC: Relay ON: Relay OFF: 1. 5 VA (1. 3 W) 0. 8 VA (0. 5 W) 1. 8 VA (1. 5 W) 1. 2 VA (0. 9 W) 0. 9 W 0. 07 W H3Y-2/H3Y-4 110, 220 VAC (50/60 Hz), 24 VDC (see note)
H3Y
Control outputs Note:
H3Y-2: 5 A at 250 VAC, resistive load (cos = 1) H3Y-4: 3 A at 250 VAC, resistive load (cos = 1)
With DC ratings, single-phase full-wave rectified power sources may be used.
Characteristics
Accuracy of operating time Setting error Reset time Influence of voltage Influence of temperature Insulation resistance Dielectric strength ±2% max. [. . . ] Maximum current of 0. 2 A can be switched if L/R is 7 ms. In both cases, a life of 100, 000 operations can be expected. The minimum applicable load is 1 mA at 1 VDC (P reference value).
Load current (A)
Load current (A)
Operation
Timing Chart
H3Y-2 H3Y-4
Time limit contact NC (9-1, 12-4)
Time limit contact NC (9-1, 10-2, 11-3, 12-4)
3
H3Y
H3Y
Dimensions
Note: All units are in millimeters unless otherwise indicated.
Timers
H3Y-2 H3Y-4
28 max. 6. 3
28 max.
6. 4 (63. 0)
Accessories (Order Separately)
Use the PYFjA, PYj, PYj-02, or PYjQN(2) to mount the H3Y. When ordering any one of these sockets, replace "j" with "08" or "14. "
Track Mounting/Front Connecting Sockets PYF08A
Two, 4. 2 × 5 mounting holes 6 Eight, M3 × 8 sems 3. 4
Terminal Arrangement (Top View)
Mounting Holes
Two, 4. 5 dia. 35. 4 59±0. 3 90. 5 86. 6
4 6 23 max. 16. 5 30 max.
PYFjA
15±0. 2
PYF14A
Two, 4. 2 × 5 mounting holes 6
3. 4 Fourteen, M3 × 8 sems
Terminal Arrangement (Top View)
Mounting Holes
Two, 4. 5 dia. M4 or M3
72 max.
35. 4 59±0. 3
4 29. 5 max. 6 22±0. 2
4
H3Y
PYF08A-N
22 max.
H3Y
Terminal Arrangement
42 4 44 8 12 1 14 5
Mounting Holes (for Surface Mounting)
4 42 8 44
1 12 5 14
3. 2 dia. 19. 8 3. 6 dia.
PYF-08A-N
41 12 11 9
12 41 14
9 11 14 13
A2
A2
A1
14
14
13
A2 A2 A1
30 max.
PYF14A-N
Terminal Arrangement
4 42 8 44 3 32 7 34 2 22 6 24 1 12 5 14
42 32 22 12 4321 44 34 24 14 8765
Mounting Holes (for Surface Mounting)
Two, 3. 5 dia.
66. 5 max.
PYF-14A-N
41 12 31 11 21 10 11 9
20. 8 12 11 10 9 41 31 21 11 14 14 A2 A2 13 A1
A2 14
A2 14
A1 13
30 max.
29. 5 max.
PYF08A-E
Two, 4. 2 × 5 mounting holes Eight, M3 × 8 sems
(Top View)
Two, 4. 5 dia. 31 max.
PYF14A-E
Two, 4. 2 × 5 mounting holes
Eight, M3 × 8 sems
(Top View)
Two, 4. 5 dia. 31 max.
5
H3Y
Back Connecting Sockets PY08, PY14
Eight, 3 × 1. 2 dia. holes only for PY08 (Fourteen, 3 × 1. 2 dia. 2. 6 29. 5 max.
H3Y
Terminal Arrangement (Bottom View)
Panel Cutout
21. 4 0
+0. 2
59. 3 25. 8 +0. 2 0
H3Y Series
2. 7 20 max.
7. 7
PY08
PY14 PYj, PYj-02, PYjQN(2)
PY08QN, PY14QN PY08QN(2), PY14QN(2)
2. 7 25 max. 22 max.
Terminal Arrangement (Bottom View)
29. 5 max.
** 41. 5 max. (see note) Note:
1x1
PY08QN PY08QN(2)
PY14QN PY14QN(2)
With PYjQN(2), dimension * should read 20 max. and dimension ** 36. 5 max.
PY08-02, PY14-02
22 max. 2
Terminal Arrangement (Bottom View)
2. 7 16. 5 max.
4. 3
PY08-02
PY14-02
6
H3Y
Socket Mounting Plates (t = 1. 6)
Applicable socket PY08, PY14, PY08QN(2), PY14QN(2) Note: PYP-1
Two, 3. 4-dia. [. . . ] Make sure that there is a space of 5 mm or more between any H3Y Models next to each other to allow heat radiation. The internal parts may become damaged if a supply voltage other than the rated ones is imposed on the H3Y. When more than 100 V is applied to 12 or 24 VDC, the internal element (varistor) may break.
Do not connect the H3Y as shown in the following circuit diagram on the right hand side, otherwise the H3Y's internal contacts different from each other in polarity may become short-circuited.
Correct Incorrect
Limited issue for Southeast Asian countries ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0. 03937. [. . . ]
DISCLAIMER TO DOWNLOAD THE USER GUIDE OMRON H3Y
Lastmanuals offers a socially driven service of sharing, storing and searching manuals related to use of hardware and software : user guide, owner's manual, quick start guide, technical datasheets... In any way can't Lastmanuals be held responsible if the document you are looking for is not available, incomplete, in a different language than yours, or if the model or language do not match the description. Lastmanuals, for instance, does not offer a translation service.
Click on "Download the user manual" at the end of this Contract if you accept its terms, the downloading of the manual OMRON H3Y will begin.